Ten Years of Lateral Flow Immunoassay Technique Applications: Trends, Challenges and Future Perspectives

被引:256
作者
Di Nardo, Fabio [1 ]
Chiarello, Matteo [1 ]
Cavalera, Simone [1 ]
Baggiani, Claudio [1 ]
Anfossi, Laura [1 ]
机构
[1] Univ Torino, Dept Chem, I-10125 Turin, Italy
关键词
lateral flow immunoassay; lateral flow assay applications; paper-based biosensor; immunochromatographic strip test; rapid diagnostic test; point-of-care testing; RAPID QUANTITATIVE DETECTION; IMMUNOCHROMATOGRAPHIC ASSAY; MONOCLONAL-ANTIBODY; SENSITIVE DETECTION; ISOTHERMAL AMPLIFICATION; MULTIPLEXED DETECTION; STRIP ASSAY; PAPER STRIP; VALIDATION; DIAGNOSIS;
D O I
10.3390/s21155185
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The Lateral Flow Immunoassay (LFIA) is by far one of the most successful analytical platforms to perform the on-site detection of target substances. LFIA can be considered as a sort of lab-in-a-hand and, together with other point-of-need tests, has represented a paradigm shift from sample-to-lab to lab-to-sample aiming to improve decision making and turnaround time. The features of LFIAs made them a very attractive tool in clinical diagnostic where they can improve patient care by enabling more prompt diagnosis and treatment decisions. The rapidity, simplicity, relative cost-effectiveness, and the possibility to be used by nonskilled personnel contributed to the wide acceptance of LFIAs. As a consequence, from the detection of molecules, organisms, and (bio)markers for clinical purposes, the LFIA application has been rapidly extended to other fields, including food and feed safety, veterinary medicine, environmental control, and many others. This review aims to provide readers with a 10-years overview of applications, outlining the trends for the main application fields and the relative compounded annual growth rates. Moreover, future perspectives and challenges are discussed.
引用
收藏
页数:33
相关论文
共 294 条
[1]   Validity of a single antibody-based lateral flow immunoassay depending on graphene oxide for highly sensitive determination of E. coli O157:H7 in minced beef and river water [J].
Abdelazeem Hassan, Abdelrahim Hussein ;
Francisco Bergua, Jose ;
Morales-Narvaez, Eden ;
Mekoci, Arben .
FOOD CHEMISTRY, 2019, 297
[2]   Tobacco Use Classification by Inexpensive Urinary Cotinine Immunoassay Test Strips [J].
Achilihu, Honest ;
Feng, June ;
Wang, Lanqing ;
Bernert, John T. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (02) :149-153
[3]  
Advice on the Use of Point-Of-Care Immunodiagnostic Tests for COVID-19, WHO2019NCOVSCIBRIEFP
[4]   Sensitive and rapid lateral-flow assay for early detection of subclinical mammary infection in dairy cows [J].
Alhussien, Mohanned Naif ;
Dang, Ajay Kumar .
SCIENTIFIC REPORTS, 2020, 10 (01)
[5]   Developments of microfluidic paper-based analytical devices (μPADs) for water analysis: A review [J].
Almeida, M. Ines G. S. ;
Jayawardane, B. Manori ;
Kolev, Spas D. ;
McKelvie, Ian D. .
TALANTA, 2018, 177 :176-190
[6]  
Amiard J.C., 2015, Aquatic Ecotoxicology, P51
[7]  
Amiard-Triquet C., 2015, Aquatic Ecotoxicology, P1, DOI [10.1016/B978-0-12-800949-9.00001-2, DOI 10.1016/B978-0-12-800949-9.00001-2]
[8]  
Anfossi L., 2019, ENCY ANAL SCI, V3rd ed., P25
[9]   Multiplex Lateral Flow Immunoassay: An Overview of Strategies towards High-throughput Point-of-Need Testing [J].
Anfossi, Laura ;
Di Nardo, Fabio ;
Cavalera, Simone ;
Giovannoli, Cristina ;
Baggiani, Claudio .
BIOSENSORS-BASEL, 2018, 9 (01)
[10]   Silver and gold nanoparticles as multi-chromatic lateral flow assay probes for the detection of food allergens [J].
Anfossi, Laura ;
Di Nardo, Fabio ;
Russo, Alida ;
Cavalera, Simone ;
Giovannoli, Cristina ;
Spano, Giulia ;
Baumgartner, Sabine ;
Lauter, Kathrin ;
Baggiani, Claudio .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (09) :1905-1913