Patient-administered sequential spirometry in healthy volunteers and patients with alpha(1)-antitrypsin deficiency

被引:10
作者
Madsen, F [1 ]
Ulrik, CS [1 ]
Dirksen, A [1 ]
Hansen, KK [1 ]
Nielsen, NH [1 ]
Frolund, L [1 ]
Viskum, K [1 ]
KokJensen, A [1 ]
机构
[1] BISPEBJERG HOSP, DEPT PULM MED, DK-2400 COPENHAGEN, DENMARK
关键词
D O I
10.1016/S0954-6111(96)90154-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The launching of cheap, pocket-sized spirometers, with data storage capability, has made patient-administered sequential spirometry (PASS) an attractive method of monitoring ventilatory capacity. At present, little information is available on the quality of PASS, compared to laboratory spirometry. The aim of this study was to investigate whether patients could perform PASS without loss of reliability and reproducibility as compared with traditional laboratory spirometry. Ten healthy volunteers performed spirometry for 1 month and 10 emphysematous patients with alpha(1)-antitrypsin deficiency (type PiZ) performed spirometry twice daily for up to 2 yr. To fulfil Good Clinical Practice criteria on full data documentation, a traditional direct recording spirometer, the Vitalograph R-model, was used. A decompression device was used for calibration and a 3.8% annual drift in volume registration was noted. This drift was largest for the first year. After training, all patients were able to perform unsupervised spirometry, producing technically correct forced expiratory curves. Reproducibility of FEV(1) and FVC obtained by PASS was found to be as good as for laboratory spirometry. After adjustment for the diurnal variation, the residual variation of FEV(1) was 2.5% (range 1.6-4.2%) for healthy volunteers and 5.6% (range 4.2-7.7%) for emphysematous patients. Forced vital capacity showed the same pattern. In conclusion, PASS is possible in highly motivated individuals without loss of reliability and reproducibility when compared to laboratory spirometry.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 30 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
[Anonymous], 1994, Respir Med, V88, P165
[3]  
BJORTUFT O, 1993, EUR RESPIR J, V6, P705
[4]  
BURROWS B, 1983, AM REV RESPIR DIS, V127, pS42
[5]  
CPMP Working Party on Efficacy of Medicinal Products, 1990, PHARMACOL TOXICOL, V67, P361
[6]  
DIRKSEN A, 1993, AM REV RESPIR DIS, V147, pA325
[7]  
DIRKSEN A, 1994, AM J RESP CRIT CARE, V149, pA1008
[8]  
DIRKSEN A, 1991, EUR RESPIR REV, V1, P432
[9]  
DOMPELING E, 1991, EUR RESPIR J, V4, P612
[10]   SPIROMETRY IN THE LUNG HEALTH STUDY .1. METHODS AND QUALITY-CONTROL [J].
ENRIGHT, PL ;
JOHNSON, LR ;
CONNETT, JE ;
VOELKER, H ;
BUIST, AS .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (06) :1215-1223