Performance of a PV module integrated with standalone building in hot arid areas as enhanced by surface cooling and cleaning

被引:85
作者
Elnozahy, Ahmed [1 ]
Rahman, Ali K. Abdel [1 ]
Ali, Ahmed Hamza H. [2 ]
Abdel-Salam, Mazen [3 ]
Ookawara, S. [4 ]
机构
[1] Egypt Japan Univ Sci & Technol E JUST, Dept Energy Recourses Engn, Alexandria 21934, Egypt
[2] Egypt Japan Univ Sci & Technol E JUST, Ctr Res Excellence Energy Resources & Management, Alexandria 21934, Egypt
[3] Assiut Univ, Dept Elect Engn, Assiut, Egypt
[4] Tokyo Inst Technol, Tokyo 152, Japan
关键词
Automatic cooling and cleaning system; Control circuit; PV module; Film of water; Bernoulli equation; SOLAR COLLECTORS; PHOTOVOLTAIC PANELS; SYSTEM; DESIGN; WATER; FLOW; EFFICIENCY; FRONT; CELLS;
D O I
10.1016/j.enbuild.2014.12.012
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study investigated experimentally the performance due to automatic cooling and surface cleaning of Photovoltaic (PV) module installed on the roof of a building in hot arid area as compared with that of a module without cooling and cleaning. The module cooling is controlled automatically according to the rear side temperature via rejection of none-converted solar-energy to the ambient to keep the PV module surface temperature always close to the ambient temperature. In addition, this system controls the cleaning period of the module front surface. The results showed a decrease of about 45.5% and 39% in module temperature at front and rear faces, respectively. Consequently, the cooled and surface cleaned module has an efficiency of 11.7% against 9% for the module without cooling and cleaning. Moreover, the maximum output power produced by cooled and cleaned module is 89.4W against 68.4W for non-cooled and non-cleaned module. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:100 / 109
页数:10
相关论文
共 26 条
[1]   Improving the effectiveness of a photovoltaic water pumping system by spraying water over the front of photovoltaic cells [J].
Abdolzadeh, M. ;
Ameri, M. .
RENEWABLE ENERGY, 2009, 34 (01) :91-96
[2]   Effects of evaporative cooling on efficiency of photovoltaic modules [J].
Alami, Abdul Hai .
ENERGY CONVERSION AND MANAGEMENT, 2014, 77 :668-679
[3]   Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq [J].
Amori, Karima E. ;
Al-Najjar, Hussein M. Taqi .
APPLIED ENERGY, 2012, 98 :384-395
[4]  
[Anonymous], MENT, DOI DOI 10.1016/J
[5]   Performance evaluation of a PV (photovoltaic) module by back surface water cooling for hot climatic conditions [J].
Bahaidarah, H. ;
Subhan, Abdul ;
Gandhidasan, P. ;
Rehman, S. .
ENERGY, 2013, 59 :445-453
[6]  
Bruce R Munson W.W., 2009, FUNDAMENTALS FLUID M, VSixth
[7]   A review on the thermal regulation techniques for non integrated flat PV modules mounted on building top [J].
Chandrasekar, M. ;
Rajkumar, S. ;
Valavan, D. .
ENERGY AND BUILDINGS, 2015, 86 :692-697
[8]   Passive cooling of standalone flat PV module with cotton wick structures [J].
Chandrasekar, M. ;
Suresh, S. ;
Senthilkumar, T. ;
Karthikeyana, M. Ganesh .
ENERGY CONVERSION AND MANAGEMENT, 2013, 71 :43-50
[9]   Exergoeconomic analysis of high concentration photovoltaic thermal co-generation system for space cooling [J].
Garcia-Heller, Veronica ;
Paredes, Stephan ;
Ong, Chin Lee ;
Ruch, Patrick ;
Michel, Bruno .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 34 :8-19
[10]   A UK-based assessment of hybrid PV and solar-thermal systems for domestic heating and power: System performance [J].
Herrando, Maria ;
Markides, Christos N. ;
Hellgardt, Klaus .
APPLIED ENERGY, 2014, 122 :288-309