Ratiometric fluorescence detection of Cd2+ and Pb2+ by inner filter-based upconversion nanoparticle-dithizone nanosystem

被引:45
作者
Chen, Min [1 ]
Kutsanedzie, Felix Y. H. [1 ]
Cheng, Wu [1 ]
Li, Huanhuan [1 ]
Chen, Quansheng [1 ]
机构
[1] Jiangsu Univ, Sch Food & Biol Engn, Zhenjiang 212013, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Upconversion; Ratiometric fluorescence; Dithizone; Inner filter; Cd2+; Pb2+; ULTRASENSITIVE DETECTION; COLORIMETRIC DETECTION; ELECTROCHEMICAL SENSOR; SILVER NANOPARTICLES; GOLD NANOPARTICLES; SELECTIVE DETECTION; MODIFIED ELECTRODE; CADMIUM IONS; PROBE; LEAD(II);
D O I
10.1016/j.microc.2018.09.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports a fluorescence sensor based on inner filter effect (IFE) between upconversion nanoparticles (UCNPs) and dithizone for the highly selective and sensitive detection of cadmium ion (Cd2+) and lead ion (Pb2+) in black tea. The fluorescence at 546 nm, 657 nm, 758 nm and 812 nm were obtained and applied as signal indicator upon upconversion nanoparticles excitation at the single wavelength of 980 nm. With the formation of UCNPs-dithizone mixed system pH at 8, the dithizone-Cd2+ complex increases with increasing in concentration of Cd2+, which cause the bathochromic shifting in absorption bands and an upconversion fluorescence (UCF) quenching at 546 nm; at pH 6, the absorption band of dithizone shows a blue shift with addition of Pb2+, leading an upconversion fluorescence recovering at 657 nm. However, in the presence/absence of Cd2+/Pb2+, the fluorescence at 758 nm and 812 nm were not influenced. This implies the Cd2+ and Pb2+ concentration could be monitored based on the fluorescence ratio I-546/I-758 and I-657/I-758 respectively. Under optimal condition, the fluorescence show a good linear within the ranges of 0.01 mu M-1.0 mu M for Cd2+; and 0.025 mu M-1.0 mu M for Pb2+, with a detection limit of 3.7 and 8.4 nM achieved. The method was applied for Cd2+ and Pb2+ in real sample (black tea and tap water) with recoveries of 99.6% to 108% and RSD value in the range of 0.96 to 1.23 for Cd2+, with recoveries of 96% to 103.2% and RSD value in the range of 0.98 to 1.27 for Pb2+ .
引用
收藏
页码:296 / 302
页数:7
相关论文
共 46 条
[1]   Thymine chitosan nanomagnets for specific preconcentration of mercury(II) prior to analysis using SELDI-MS [J].
Abdelhamid, Hani Nasser ;
Lin, Yu Chih ;
Wu, Hui-Fen .
MICROCHIMICA ACTA, 2017, 184 (05) :1517-1527
[2]   Femtomolar detection of mercuric ions using polypyrrole, pectin and graphene nanocomposites modified electrode [J].
Arulraj, Abraham Daniel ;
Devasenathipathy, Rajkumar ;
Chen, Shen-Ming ;
Vasantha, Vairathevar Sivasamy ;
Wang, Sea-Fue .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 483 :268-274
[3]   Core-Size Dependent Fluorescent Gold Nanoclusters and Ultrasensitive Detection of Pb2+ Ion [J].
Bain, Dipankar ;
Maity, Subarna ;
Paramanik, Bipattaran ;
Patra, Amitava .
ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2018, 6 (02) :2334-2343
[4]   Sensitive determination of chromium (VI) based on the inner filter effect of upconversion luminescent nanoparticles (NaYF4:Yb3+, Er3+) [J].
Chen, Hongqi ;
Ren, Jicun .
TALANTA, 2012, 99 :404-408
[5]   Sensitive fluorescent detection of H2O2 and glucose in human serum based on inner filter effect of squaric acid-iron(III) on the fluorescence of upconversion nanoparticle [J].
Chen, Hongyu ;
Fang, Aijin ;
He, Li ;
Zhang, Youyu ;
Yao, Shouzhuo .
TALANTA, 2017, 164 :580-587
[6]   Synthesis of improved upconversion nanoparticles as ultrasensitive fluorescence probe for mycotoxins [J].
Chen, Quansheng ;
Hu, Weiwei ;
Sun, Cuicui ;
Li, Huanhuan ;
Ouyang, Qin .
ANALYTICA CHIMICA ACTA, 2016, 938 :137-145
[7]   Electrochemical sensor using NH2-MIL-88(Fe)-rGO composite for trace Cd2+, Pb2+, and Cu2+ detection [J].
Duan, Shuo ;
Huang, Yuming .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 807 :253-260
[8]   Design of an electrochemical DNA-based biosensor for selective determination of cadmium ions using a DNA hybridization indicator [J].
Ebrahimi, Maryam ;
Raoof, Jahan Bakhsh ;
Ojani, Reza .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 108 :1237-1241
[9]   Upconversion nanosensor for sensitive fluorescence detection of Sudan I-IV based on inner filter effect [J].
Fang, Aijin ;
Long, Qian ;
Wu, Qiongqiong ;
Li, Haitao ;
Zhang, Youyu ;
Yao, Shouzhuo .
TALANTA, 2016, 148 :129-134
[10]   Graphene oxide-based electrochemical sensor: a platform for ultrasensitive detection of heavy metal ions [J].
Gong, Xuezhong ;
Bi, Yunlong ;
Zhao, Yihua ;
Liu, Guozhen ;
Teoh, Wey Yang .
RSC ADVANCES, 2014, 4 (47) :24653-24657