Comparison of Various Analysis Methods Based on Heat Flowmeters and Infrared Thermography Measurements for the Evaluation of the In Situ Thermal Transmittance of Opaque Exterior Walls

被引:29
作者
Choi, Doo Sung [1 ]
Ko, Myeong Jin [2 ]
机构
[1] Chungwoon Univ, Dept Bldg Equipment & Fire Protect Syst, Incheon 22100, South Korea
[2] Nabi Bldg Environm & Equipment Design Consultant, Seoul 06226, South Korea
来源
ENERGIES | 2017年 / 10卷 / 07期
关键词
in situ thermal transmittance; heat flowmeter; infrared thermography; on-site measurement; opaque exterior wall; BUILDING DIAGNOSTICS; U-VALUE; CONSTRUCTION; PERFORMANCE; COMPONENTS; RESISTANCE; FLOW;
D O I
10.3390/en10071019
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There are several methods to obtain the in situ thermal transmittance value (U-value) of building envelopes from on-site data, including the three approaches of the progressive average method, average method considering the thermal storage effect, and dynamic method for deriving the U-value from heat flowmeter (HFM) measurements and the four methods with different formulas to analyze infrared thermography (IRT) measurement data. Since each of these methods considers different parameters and the non-steady characteristics of the heat transfer in building walls in their own way, discrepancies may occur among the obtained results. This study evaluates and compares the in situ U-values by using various methods of analyzing HFM and IRT measurement data. Further, by investigating buildings with similar materials and identical stratigraphies, but with different construction years, we analyze the discrepancy between the designed and measured values caused by material deterioration and evaluate the errors according to the analysis method. The percentage deviation between the U-values obtained by the three methods from the HFM data is found to be satisfactory, being within 10%. When compared with the results of the progressive average method, the deviations for the four different IRT-measurement-based methods vary greatly, being in the range of 6-43%.
引用
收藏
页数:22
相关论文
共 33 条
  • [1] Adhikari R.S., 2012, P 28 INT PLEA C SUST
  • [2] A comprehensive experimental approach for the validation of quantitative infrared thermography in the evaluation of building thermal transmittance
    Albatici, Rossano
    Tonelli, Arnaldo M.
    Chiogna, Michela
    [J]. APPLIED ENERGY, 2015, 141 : 218 - 228
  • [3] Assessment of the thermal emissivity value of building materials using an infrared thermovision technique emissometer
    Albatici, Rossano
    Passerini, Francesco
    Tonelli, Arnaldo M.
    Gialanella, Stefano
    [J]. ENERGY AND BUILDINGS, 2013, 66 : 33 - 40
  • [4] Infrared thermovision technique for the assessment of thermal transmittance value of opaque building elements on site
    Albatici, Rossano
    Tonelli, Arnaldo M.
    [J]. ENERGY AND BUILDINGS, 2010, 42 (11) : 2177 - 2183
  • [5] [Anonymous], E186297 ASTM
  • [6] [Anonymous], C68014 ASTM
  • [7] [Anonymous], 69462007 ISO
  • [8] Asdrubali F., 2014, CASE STUD CONSTR MAT, V1, P53, DOI [10.1016/j.cscm.2014.04.004, DOI 10.1016/J.CSCM.2014.04.004]
  • [9] ASTM, E193399A ASTM
  • [10] PASLINK and dynamic outdoor testing of building components
    Baker, P. H.
    van Dijk, H. A. L.
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (02) : 143 - 151