Optical coherence tomography scan circle location and mean retinal nerve fiber layer measurement variability

被引:83
作者
Gabriele, Michelle L. [1 ,2 ]
Ishikawa, Hiroshi [1 ,2 ]
Wollstein, Gadi [1 ]
Bilonick, Richard A. [1 ]
Townsend, Kelly A. [1 ]
Kagemann, Larry [1 ,2 ]
Wojtkowski, Maciej [3 ,4 ,5 ]
Srinivasan, Vivek J. [3 ,4 ]
Fujimoto, James G. [3 ,4 ]
Duker, Jay S. [6 ]
Schuman, Joel S. [1 ,2 ]
机构
[1] Univ Pittsburgh, Sch Med, Dept Ophthalmol,Ophthalmol & Visual Sci Res Ctr, UPM Eye Ctr,Eye & Ear Inst, Pittsburgh, PA 15213 USA
[2] Univ Pittsburgh, Sch Engn, Dept Bioengn, Pittsburgh, PA 15213 USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA USA
[4] MIT, Elect Res Lab, Cambridge, MA USA
[5] Nicholas Copernicus Univ, Inst Phys, PL-87100 Torun, Poland
[6] Tufts Univ, Sch Med, Tufts New England Med Ctr, New England Eye Ctr, Boston, MA 02111 USA
关键词
D O I
10.1167/iovs.07-0873
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate the effect on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements of varying the standard 3.4-mm-diameter circle location. METHODS. The optic nerve head (ONH) region of 17 eyes of 17 healthy subjects was imaged with high-speed, ultrahigh-resolution OCT (hsUHR-OCT; 501 x 180 axial scans covering a 6 x 6-mm area; scan time, 3.84 seconds) for a comprehensive sampling. This method allows for systematic simulation of the variable circle placement effect. RNFL thickness was measured on this three-dimensional dataset by using a custom-designed software program. RNFL thickness was resampled along a 3.4-mm-diameter circle centered on the ONH, then along 3.4-mm circles shifted horizontally (x-shift), vertically (y-shift) and diagonally up to +/- 500 mu m (at 100-mu m intervals). Linear mixed-effects models were used to determine RNFL thickness as a function of the scan circle shift. A model for the distance between the two thickest measurements along the RNFL thickness circular profile (peak distance) was also calculated. RESULTS. RNFL thickness tended to decrease with both positive and negative x- and y-shifts. The range of shifts that caused a decrease greater than the variability inherent to the commercial device was greater in both nasal and temporal quadrants than in the superior and inferior ones. The model for peak distance demonstrated that as the scan moves nasally, the RNFL peak distance increases, and as the circle moves temporally, the distance decreases. Vertical shifts had a minimal effect on peak distance. CONCLUSIONS. The location of the OCT scan circle affects RNFL thickness measurements. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination (ClinicalTrials.gov number, NCT00286637).
引用
收藏
页码:2315 / 2321
页数:7
相关论文
共 31 条
  • [1] AIRAKSINEN PJ, 1984, AM J OPHTHALMOL, V98, P566, DOI 10.1016/0002-9394(84)90242-3
  • [2] Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
    Blumenthal, EZ
    Williams, JM
    Weinreb, RN
    Girkin, CA
    Berry, CC
    Zangwill, LM
    [J]. OPHTHALMOLOGY, 2000, 107 (12) : 2278 - 2282
  • [3] Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    Budenz, DL
    Chang, RT
    Huang, XR
    Knighton, RW
    Tielsch, JM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2440 - 2443
  • [4] Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes
    Carpineto, P
    Ciancaglini, M
    Zuppardi, E
    Falconio, G
    Doronzo, E
    Mastropasqua, L
    [J]. OPHTHALMOLOGY, 2003, 110 (01) : 190 - 195
  • [5] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    [J]. OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [6] Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
    de Boer, JF
    Cense, B
    Park, BH
    Pierce, MC
    Tearney, GJ
    Bouma, BE
    [J]. OPTICS LETTERS, 2003, 28 (21) : 2067 - 2069
  • [7] Retinal nerve fiber layer thickness measured with optical coherence tomography is related to visual function in glaucomatous eyes
    El Beltagi, TA
    Bowd, C
    Boden, C
    Amini, P
    Sample, PA
    Zangwill, LM
    Weinreb, RN
    [J]. OPHTHALMOLOGY, 2003, 110 (11) : 2185 - 2191
  • [8] Peripapillary nerve fiber layer thickness profile determined with high speed, ultrahigh resolution optical coherence tomography high-density scanning
    Gabriele, Michelle L.
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Kagemann, Larry
    Wojtkowski, Maciej
    Srinivasan, Vivek J.
    Fujimoto, James G.
    Duker, Jay S.
    Schuman, Joel S.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (07) : 3154 - 3160
  • [9] Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes
    Guedes, V
    Schuman, JS
    Hertzmark, E
    Wollstein, G
    Correnti, A
    Mancini, R
    Lederer, D
    Voskanian, S
    Velazquez, L
    Pakter, HM
    Pedut-Kloizman, T
    Fujimoto, JG
    Mattox, C
    [J]. OPHTHALMOLOGY, 2003, 110 (01) : 177 - 189
  • [10] OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA
    HEE, MR
    IZATT, JA
    SWANSON, EA
    HUANG, D
    SCHUMAN, JS
    LIN, CP
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) : 325 - 332