Corrections for sinusoidal background and non-orthogonality of signal channels in sinusoidal rapid magnetic field scans

被引:30
作者
Tseitlin, Mark [1 ]
Mitchell, Deborah G. [1 ]
Eaton, Sandra S. [1 ]
Eaton, Gareth R. [1 ]
机构
[1] Univ Denver, Dept Chem & Biochem, Denver, CO 80208 USA
基金
美国国家科学基金会;
关键词
EPR; Rapid scan; Background correction; Orthogonality in quadrature detector; EPR;
D O I
10.1016/j.jmr.2012.07.023
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapidly-changing magnetic field of sinusoidal rapid scans creates background signals that are dominated by oscillations at the scan frequency. The background oscillations can be removed without acquiring off-resonance data. For data acquired in quadrature, up-field and down-field scan signals can be separated in the frequency domain. For each scan direction, the background oscillation can be calculated by fitting to the half cycle that does not contain the EPR signal. The extrapolated fit function is then subtracted from the half cycle that contains the EPR signal. By zeroing the array for the half cycles that do not contain the EPR signal, the signal-to-noise is improved and the data are corrected for non-orthogonality of the quadrature channels. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 11 条
[1]   1-D EPR imaging of conducting and lossy-dielectric samples [J].
Aminov, LK ;
Tseitlin, MP ;
Salikhov, KM .
APPLIED MAGNETIC RESONANCE, 1999, 16 (03) :341-362
[2]   Practical conditions and limitations for high-spatial-resolution multisite EPR oximetry [J].
Grinberg, VO ;
Smirnov, AI ;
Grinberg, OY ;
Grinberg, SA ;
O'Hara, JA ;
Swartz, HM .
APPLIED MAGNETIC RESONANCE, 2005, 28 (1-2) :69-78
[3]   Rapid-scan EPR with triangular scans and fourier deconvolution to recover the slow-scan spectrum [J].
Joshi, JP ;
Ballard, JR ;
Rinard, GA ;
Quine, RW ;
Eaton, SS ;
Eaton, GR .
JOURNAL OF MAGNETIC RESONANCE, 2005, 175 (01) :44-51
[4]   X-band rapid-scan EPR of nitroxyl radicals [J].
Mitchell, Deborah G. ;
Quine, Richard W. ;
Tseitlin, Mark ;
Eaton, Sandra S. ;
Eaton, Gareth R. .
JOURNAL OF MAGNETIC RESONANCE, 2012, 214 :221-226
[5]   Comparison of continuous wave, spin echo, and rapid scan EPR of irradiated fused quartz [J].
Mitchell, Deborah G. ;
Quine, Richard W. ;
Tseitlin, Mark ;
Meyer, Virginia ;
Eaton, Sandra S. ;
Eaton, Gareth R. .
RADIATION MEASUREMENTS, 2011, 46 (09) :993-996
[6]   A pulsed and continuous wave 250 MHz electron paramagnetic resonance spectrometer [J].
Ouine, RW ;
Rinard, GA ;
Eaton, SS ;
Eaton, GR .
CONCEPTS IN MAGNETIC RESONANCE, 2002, 15 (01) :59-91
[7]   A Linear Magnetic Field Scan Driver [J].
Quine, Richard W. ;
Czechowski, Tomasz ;
Eaton, Gareth R. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2009, 35B (01) :44-58
[8]   A Wire-Crossed-Loop Resonator for Rapid Scan EPR [J].
Rinard, George A. ;
Quine, Richard W. ;
Biller, Joshua R. ;
Eaton, Gareth R. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2010, 37B (02) :86-91
[9]   Esters of 5-carboxyl-5-methyl-1-pyrroline N-oxide: A family of spin traps for superoxide [J].
Tsai, P ;
Ichikawa, K ;
Mailer, C ;
Pou, S ;
Halpern, HJ ;
Robinson, BH ;
Nielsen, R ;
Rosen, GM .
JOURNAL OF ORGANIC CHEMISTRY, 2003, 68 (20) :7811-7817
[10]   Deconvolution of sinusoidal rapid EPR scans [J].
Tseitlin, Mark ;
Rinard, George A. ;
Quine, Richard W. ;
Eaton, Sandra S. ;
Eaton, Gareth R. .
JOURNAL OF MAGNETIC RESONANCE, 2011, 208 (02) :279-283