Multifrequency Magnetic Resonance Elastography for the Assessment of Renal Allograft Function

被引:41
作者
Garcia, Stephan Rodrigo Marticorena [1 ]
Fischer, Thomas [1 ]
Duerr, Michael [2 ]
Gueltekin, Emin [1 ]
Braun, Juergen [3 ]
Sack, Ingolf [1 ]
Guo, Jing [1 ]
机构
[1] Charite Univ Med Berlin, Dept Radiol, Berlin, Germany
[2] Charite Univ Med Berlin, Dept Nephrol, Berlin, Germany
[3] Charite Univ Med Berlin, Dept Med Informat, Berlin, Germany
关键词
multifrequency magnetic resonance elastography; kidney; renal allograft; shear waves; renal stiffness; renal dysfunction; MR ELASTOGRAPHY; TRANSIENT ELASTOGRAPHY; TISSUE ELASTICITY; KIDNEY; STIFFNESS; FIBROSIS; FEASIBILITY; DIAGNOSIS; HISTOLOGY; BIOPSY;
D O I
10.1097/RLI.0000000000000271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this study was to apply multifrequency magnetic resonance elastography (MMRE) for assessment of kidney function based on renal stiffness of allografts in transplant recipients and native kidneys in controls. Methods: In this prospective study, MMRE was used to measure stiffness in transplant kidneys in 22 recipients (age range, 23-73 years; 7 females) and in native kidneys in 11 controls (age range, 26-55 years; 4 females) after internal review board approval. TheMMREwas performed on a 1.5 Tmagnetic resonance imaging scanner using 4 vibration frequencies from 40 to 70 Hz. Stiffness maps were computed by multifrequency reconstruction of the magnitude shear modulus (vertical bar G*vertical bar). Clinical markers such as glomerular filtration rate (GFR) and resistive index (RI) were acquired. Differences in renal stiffness among groups were compared by Mann-Whitney U test. Correlations were tested using Pearson correlation. Results: Functioning transplants had higher stiffness (vertical bar G*vertical bar = 9.00 +/- 1.71 kPa) than nonfunctioning transplants (vertical bar G*vertical bar = 5.88 +/- 1.71 kPa, P < 0.001) and native kidneys (vertical bar G*vertical bar = 6.63 +/- 1.63 kPa, P < 0.01). A cutoff value of 7.04 kPa provided sensitivity (83.33%) and specificity (86.67%) for detecting renal allograft dysfunction with an area under the receiver operating characteristic curve value of 0.9278 (95% confidence interval, 0.83-1.00). vertical bar G*vertical bar correlated positively with GFR (r = 0.52, P = 0.015) and negatively with RI (r = -0.52, P = 0.016). Conclusions: Multifrequency magnetic resonance elastography has good diagnostic accuracy in detecting renal allograft dysfunction. Renal stiffness is significantly lower in recipients with nonfunctioning transplant kidneys and correlates with clinical markers such as GFR and RI.
引用
收藏
页码:591 / 595
页数:5
相关论文
共 28 条
  • [1] Noninvasive evaluation of renal allograft fibrosis by transient elastography - a pilot study
    Arndt, Robert
    Schmidt, Sven
    Loddenkemper, Christoph
    Gruenbaum, Maria
    Zidek, Walter
    van der Giet, Markus
    Westhoff, Timm H.
    [J]. TRANSPLANT INTERNATIONAL, 2010, 23 (09) : 871 - 877
  • [2] Stiffness imaging of the kidney and adjacent abdominal tissues measured simultaneously using magnetic resonance elastography
    Bensamoun, Sabine F.
    Robert, Ludovic
    Leclerc, Gwladys E.
    Debernard, Laetitia
    Charleux, Fabrice
    [J]. CLINICAL IMAGING, 2011, 35 (04) : 284 - 287
  • [3] Physiology in perspective:: The Wisdom of the Body.: Neural control of the kidney
    DiBona, GF
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-REGULATORY INTEGRATIVE AND COMPARATIVE PHYSIOLOGY, 2005, 289 (03) : R633 - R641
  • [4] Dittmann F, 2015, MAGN RESON MED
  • [5] SUPERSONIC SHEAR WAVE ELASTOGRAPHY OF IN VIVO PIG KIDNEY: INFLUENCE OF BLOOD PRESSURE, URINARY PRESSURE AND TISSUE ANISOTROPY
    Gennisson, Jean-Luc
    Grenier, Nicolas
    Combe, Christian
    Tanter, Mickael
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (09) : 1559 - 1567
  • [6] Patient-Activated Three-Dimensional Multifrequency Magnetic Resonance Elastography for High-Resolution Mechanical Imaging of the Liver and Spleen
    Guo, J.
    Hirsch, S.
    Streitberger, K. J.
    Kamphues, C.
    Asbach, P.
    Braun, J.
    Sack, I.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (03): : 260 - 266
  • [7] Guo J., 2015, MAGN RESON MED
  • [8] Towards an Elastographic Atlas of Brain Anatomy
    Guo, Jing
    Hirsch, Sebastian
    Fehlner, Andreas
    Papazoglou, Sebastian
    Scheel, Michael
    Braun, Juergen
    Sack, Ingolf
    [J]. PLOS ONE, 2013, 8 (08):
  • [9] MR Elastography of the Liver and the Spleen Using a Piezoelectric Driver, Single-Shot Wave-Field Acquisition, and Multifrequency Dual Parameter Reconstruction
    Hirsch, Sebastian
    Guo, Jing
    Reiter, Rolf
    Papazoglou, Sebastian
    Kroencke, Thomas
    Braun, Juergen
    Sack, Ingolf
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) : 267 - 277
  • [10] In vivo high-resolution magnetic resonance elastography of the uterine corpus and cervix
    Jiang, Xuyuan
    Asbach, Patrick
    Streitberger, Kaspar-Josche
    Thomas, Anke
    Hamm, Bernd
    Braun, Juergen
    Sack, Ingolf
    Guo, Jing
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (12) : 3025 - 3033