Air-side heat transfer enhancement of a refrigerator evaporator using vortex generation

被引:73
作者
Sommers, AD [1 ]
Jacobi, AM [1 ]
机构
[1] Univ Illinois, Dept Mech & Ind Engn, Urbana, IL 61801 USA
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2005年 / 28卷 / 07期
关键词
domestic refrigeration; display cabinet; evaporator; improvement; heat transfer; air; finned tube; vortex;
D O I
10.1016/j.ijrefrig.2005.04.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
In most domestic and commercial refrigeration systems, frost forms on the air-side surface of the air-to-refrigerant heat exchanger. Frost-tolerant designs typically employ a large fin spacing in order to delay the need for a defrost cycle. Unfortunately, this approach does not allow for a very high air-side heat transfer coefficient, and the performance of these heat exchangers is often air-side limited. Longitudinal vortex generation is a proven and effective technique for thinning the thermal boundary layer and enhancing heat transfer, but its efficacy in a frosting environment is essentially unknown. In this study, an array of delta-wing vortex generators is applied to a plain-fin-and-tube heat exchanger with a fin spacing of 8.5 mm. Heat transfer and pressure drop performance are measured to determine the effectiveness of the vortex generator under frosting conditions. For air-side Reynolds numbers between 500 and 1300, the air-side thermal resistance is reduced by 35-42% when vortex generation is used. Correspondingly, the heat transfer coefficient is observed to range from 33 to 53 W m(-2) K-1 for the enhanced heat exchanger and from 18 to 26 W m(-2) K-1 for the baseline heat exchanger. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:1006 / 1017
页数:12
相关论文
共 21 条
[1]   Predictions of frost growth on a cold plate in atmospheric air [J].
Cheng, CH ;
Cheng, YC .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2001, 28 (07) :953-962
[2]  
DAVIS MA, 1996, TR107 ACRC
[3]   The thermal-hydraulic impact of delta-wing vortex generators on the performance of a plain-fin-and-tube heat exchanger [J].
ElSherbini, AI ;
Jacobi, AM .
HVAC&R RESEARCH, 2002, 8 (04) :357-370
[4]   Vortices, generators and heat transfer [J].
Fiebig, M .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 1998, 76 (A2) :108-123
[5]   Heat transfer enhancement by delta-wing vortex generators ion a flat plate: Vortex interactions with the boundary layer [J].
Gentry, MC ;
Jacobi, AM .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 14 (03) :231-242
[6]   STUDY OF FROST PROPERTIES CORRELATING WITH FROST FORMATION TYPES [J].
HAYASHI, Y ;
AOKI, A ;
ADACHI, S ;
HORI, K .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1977, 99 (02) :239-245
[7]   Study on sublimation phenomenon of horizontal frost layer exposed to forced convection air flow and radiant heat [J].
Inaba, H ;
Imai, S .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1996, 118 (03) :694-701
[8]   Heat transfer and flow characteristics of fin-tube bundles with and without winglet-type vortex generators [J].
Kwak, KM ;
Torii, K ;
Nishino, K .
EXPERIMENTS IN FLUIDS, 2002, 33 (05) :696-702
[9]   A one-dimensional model for frost formation on a cold flat surface [J].
Lee, KS ;
Kim, WS ;
Lee, TH .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (18) :4359-4365
[10]   Modelling of frost growth and densification [J].
LeGall, R ;
Grillot, JM ;
Jallut, C .