Voltage Sensitivity Based Reactive Power Control on VSC-HVDC in A Wind Farm Connected Hybrid Multi-Infeed HVDC System

被引:0
|
作者
Liu, Yan [1 ]
Chen, Zhe [1 ]
机构
[1] Aalborg Univ, Dept Energy Technol, Aalborg, Denmark
来源
2013 IEEE GRENOBLE POWERTECH (POWERTECH) | 2013年
关键词
Offshore wind farm; VSC-HVDC; Low Voltage Ride Through; TURBINES; FLICKER;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
With increasing application of both Line Commutated Converter based High Voltage Direct Current (LCC-HVDC) systems and Voltage Source Converter based HVDC (VSC-HVDC) links, a new type of system structure named Hybrid Multi-Infeed HVDC (HMIDC) system is formed in the modern power systems. This paper presents the operation and control method of the wind farm connected HMIDC system. The wind power fluctuation takes large influence to the system voltages. In order to reduce the voltage fluctuation of LCC-HVDC infeed bus caused by the wind power variation, a voltage sensitivity-based reactive power control method is proposed in the paper. According to the calculated sensitivity factors, a reactive power increment is added in the control loop of VSC-HVDC so as to regulate the voltage of the target bus. Dynamic simulations in PSCAD/EMTDC and MATLAB are presented to assess the performance of the proposed control method.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Analysis of VSC-HVDC support capability for power grids with large-scale renewable energy and multi-infeed HVDC links
    Xing, Pengxiang
    Yang, Youhang
    Peng, Jiasheng
    Yu, Linlin
    Si, Ruihua
    Jia, Peng
    Wang, Chuanjie
    Wen, Yunfeng
    ENERGY REPORTS, 2023, 9 : 1084 - 1091
  • [12] Active and reactive power control of a VSC-HVdc
    Latorre, H. F.
    Ghandhari, M.
    Soder, L.
    ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (10) : 1756 - 1763
  • [13] Control of VSC-HVDC connected wind farms for system frequency support
    Guo, Xiaolong
    Yan, Jiaming
    Xu, Guoyi
    Hu, Jiaxin
    Bi, Tianshu
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (05)
  • [14] Considering reactive power coordinated control of hybrid multi-infeed HVDC system research into emergency DC power support
    Li, Congshan
    Li, Yikai
    He, Ping
    Guo, Jian
    Fang, Yan
    Sheng, Tingyu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (20) : 4541 - 4550
  • [15] Particle swarm optimization based PI controller of VSC-HVDC system connected to a wind farm
    Mazouz, Lakhdar
    Zidi, Sid Ahmed
    Khatir, Mohamed
    Benmessaoud, Tahar
    Saadi, Slami
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2016, 7 (01) : 239 - 246
  • [16] Wideband oscillation analysis of VSC-HVDC connected DFIG wind farm
    Liu, Xinyuan
    Ma, Yanfeng
    Jia, Jia
    Zhao, Shuqiang
    ENERGY REPORTS, 2024, 12 : 837 - 844
  • [17] Low Voltage Ride-through Strategy for Wind Farm and VSC-HVDC
    Niu, Lele
    Wang, Xiao
    Wu, Linlin
    Yan, Feng
    Xu, Man
    Hu, Xiaobao
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 2183 - 2188
  • [18] A Passivity Control Strategy for VSC-HVDC Connected Large Scale Wind Power
    Fan, Xinming
    Guan, Lin
    Xia, Chengjun
    He, Jianming
    2013 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES (ISGT), 2013,
  • [19] Coordinated LVRT control of wind power generation system based on VSC-HVDC
    Zhang, Xinyin
    Hu, Minqiang
    Wu, Zaijun
    Hao, Sipeng
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2014, 34 (03): : 138 - 143
  • [20] Probabilistic optimal power flow of AC/DC system with offshore wind farm connected to grid via VSC-HVDC
    Research Center for Renewable Energy Generation Engineering, Ministry of Education, Hohai University, Nanjing
    210098, China
    不详
    224005, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 9 (136-142): : 136 - 142