Mechanical properties of reinforcing and prestressing steels after heating

被引:97
作者
Neves, IC
Rodrigues, JPC
Loureiro, AD
机构
[1] UNIV TECN LISBOA, INST SUPER TECN, DEPT MAT ENGN, P-1096 LISBON, PORTUGAL
[2] UNIV COIMBRA, FAC SCI & TECHNOL, DEPT CIVIL ENGN, P-3049 COIMBRA, PORTUGAL
关键词
D O I
10.1061/(ASCE)0899-1561(1996)8:4(189)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports test results showing how the heating-cooling process like the one occurring during fire action can affect the tensile strength and the strain after rupture of the steels normally used in reinforced and prestressed concrete structures. Laboratory tests were carried out to assess the values of these. properties after heating. In these tests, steel samples were heated up to different temperature levels followed by a cooling process. Cooling in the air, cooling by waterjet, and cooling by total immersion in water with agitation were the cooling processes used. For temperatures up to 600 degrees C, the tested reinforcing steel showed no major alterations. However, for temperatures above 700 degrees C, important changes in the steel properties could be observed. For the prestressing steel, those alterations began at 400 degrees C.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 11 条
  • [1] ANCHOR RD, 1991, B COMITE EUROINTERNA, V208
  • [2] ANCHOR RD, 1986, DESIGN STRUCTURES FI
  • [3] Harmathy TZ, 1993, FIRE SAFETY DESIGN C
  • [4] HOLMES M, 1982, STRUCT ENG-B, V60, P7
  • [5] Kirby B.R., 1986, REINSTATEMENT FIRE D
  • [6] Kordina K, 1981, BETON BRANDSCHUTZ HD
  • [7] KRAMPF L, 1986, EVALUATION REPAIR FI, P115
  • [8] MALHOTRA HL, 1982, DESIGN FIRE RESISTIN
  • [9] RODRIGUES JPC, 1994, THESIS U COIMBRA POR
  • [10] SCHNEIDER U, 1989, W14 CIB CONS INT BAT