In Vivo High Frame Rate Vector Flow Imaging Using Plane Waves and Directional Beamforming

被引:0
|
作者
Jensen, Jonas [1 ]
Hoyos, Carlos Armando Villagomez [1 ]
Stuart, Matthias Bo [1 ]
Ewertsen, Caroline [2 ]
Nielsen, Michael Bachmann [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, DK-2800 Lyngby, Denmark
[2] Copenhagen Univ Hosp, Dept Radiol, DK-2100 Copenhagen, Denmark
关键词
VELOCITY VECTORS; ULTRASOUND;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Directional beamforming (DB) estimates blood flow velocities accurately when the flow angle is known. However, for automatically finding the flow angle a computationally expensive approach is used. This work presents a method for estimating the flow angle using a combination of inexpensive transverse oscillation (TO) estimators and only 3 directional beamformed lines. The suggested DB vector flow estimator is employed with steered plane wave transmissions for high frame rate imaging. Two distinct plane wave sequences are used: a short sequence (3 angles) for fast flow and an interleaved long sequence (21 angles) for both slow flow and B-mode. Parabolic flow with a peak velocity of 0.5 m/s is measured at beam-to-flow angles of 60 degrees and 90 degrees. The DB method estimates the angle with a bias and standard deviation (STD) less than 2 degrees, and the STD of the velocity magnitude is 2.5 %. This is 7 - 8.5 % when using TO. The long sequence has a higher sensitivity, and when used for estimation of slow flow with a peak velocity of 0.04 m/s, the SD is 2.5 % and bias is 0.1 %. This is a factor of 4 better than if the short sequence is used. The carotid bifurcation was scanned on a healthy volunteer, and the short sequence was used with TO and DB to estimate velocity vectors. The STD of the velocity profile over a cardiac cycle was 6.1 % for TO and 4.9 % for DB.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] High Frame Rate Vector Flow Imaging of Stenotic Carotid Bifurcation: Computational Modeling and Analysis
    Chan, Donald L. S.
    Yiu, Billy Y. S.
    Yu, Alfred C. H.
    2011 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2011, : 409 - 412
  • [32] A beamforming method for plane wave Doppler imaging of high flow velocities
    Mansour, Omar
    Poepping, Tamie L.
    Lacefield, James C.
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [33] Wide-Angle Tissue Doppler Imaging at High Frame Rate Using Multi-Line Transmit Beamforming: An Experimental Validation In Vivo
    Tong, Ling
    Ramalli, Alessandro
    Tortoli, Piero
    Fradella, Guiseppe
    Caciolli, Sabina
    Luo, Jianwen
    D'hooge, Jan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (02) : 521 - 528
  • [34] A nonlinear beamforming for enhanced spatiotemporal sensitivity in high frame rate ultrasound flow
    Madhavanunni, A. N.
    Panicker, Mahesh Raveendranatha
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 147
  • [35] Clinical Application of High-Frame-Rate Vector Flow Imaging in Evaluation of Carotid Atherosclerotic Stenosis
    Qiu, Yi-Jie
    Cheng, Juan
    Zhang, Qi
    Yang, Dao-Hui
    Zuo, Dan
    Mao, Feng
    Liu, Ling-Xiao
    Dong, Yi
    Cao, Si-Qi
    Wang, Wen-Ping
    DIAGNOSTICS, 2023, 13 (03)
  • [36] Blood flow imaging of high frame rate two-dimensional vector in cardiovascular ultrasound detection
    Wu, Cungang
    Huang, Chao
    IET IMAGE PROCESSING, 2020, 14 (13) : 3014 - 3020
  • [37] Frequency-domain high frame-rate 2D vector flow imaging
    Lenge, M.
    Ramalli, A.
    Boni, E.
    Cellai, A.
    Liebgott, H.
    Cachard, C.
    Tortoli, P.
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 639 - 642
  • [38] Accurate Angle Estimator for High-Frame-Rate 2-D Vector Flow Imaging
    Hoyos, Carlos Armando Villagomez
    Stuart, Matthias Bo
    Hansen, Kristoffer Lindskov
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (06) : 842 - 853
  • [39] High-Frame-Rate 2-D Vector Blood Flow Imaging in the Frequency Domain
    Lenge, Matteo
    Ramalli, Alessandro
    Boni, Enrico
    Liebgott, Herve
    Cachard, Christian
    Tortoli, Piero
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (09) : 1504 - 1514
  • [40] High-Frame Rate Vector Flow Imaging of the Carotid Bifurcation in Healthy Adults: Comparison With Color Doppler Imaging
    Goddi, Alfredo
    Bortolotto, Chandra
    Raciti, Maria Vittoria
    Fiorina, Ilaria
    Aiani, Luca
    Magistretti, Giovanni
    Sacchi, Andrea
    Tinelli, Carmine
    Calliada, Fabrizio
    JOURNAL OF ULTRASOUND IN MEDICINE, 2018, 37 (09) : 2263 - 2275