Proximal versus distal screw placement for biceps tenodesis: a biomechanical study

被引:6
作者
De Villiers, Daniel Johannes [1 ,2 ]
Loh, Brian [2 ]
Tacey, Mark [1 ]
Keith, Prue [2 ]
机构
[1] Royal Melbourne Hosp, Parkville, Vic, Australia
[2] Northeast Hlth Wangaratta, Wangaratta, Vic, Australia
关键词
humerus; tenodesis; torque; TORSIONAL STRENGTH; FIXATION; MODELS; BONE;
D O I
10.1177/1602400227
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To assess the maximum and end torque of a fourth-generation composite humerus model with no screw inserted or with a screw inserted in the distal (subpectoral) position or proximal (suprapectoral) position. Methods. 24 large-size, fourth-generation composite humeri were randomised to the control (n=8), proximal (n=8), or distal (n=8) group. For the latter 2 groups, an 8-mm-head interference screw (7x25 mm) -was inserted at 1 cm proximal and 1 cm distal to the superior aspect of the insertion of the pectoralis major tendon, respectively. The maximum and end torque of each humerus was assessed. Results. Respectively for the control, proximal, and distal groups, the maximum torque was 81.8, 78.7, and 74.3 Nm, and the end torque was 80.7, 78.6, and 71.8 Nm; only the difference between control and distal groups was significant (p=0.005 for maximum torque and p=0.033 for end torque). All fractures in both control and proximal groups involved the distal 1/3 humerus. In the distal group, the fractures involved either the distal 1 / 3 humerus (n=6) or the screw-hole (n=2); the difference between the 2 types of fracture was not significant in terms of maximum torque (75.7 vs. 70.0, p=0.086) or end torque (75.3 vs. 61.4, p=0.40). Conclusion. Compared with proximal placement of an interference screw, distal placement decreased the maximum torque (though not significantly) and may increase the risk of proximal humeral fracture.
引用
收藏
页码:258 / 261
页数:4
相关论文
共 17 条
[1]   Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation [J].
Boileau, P ;
Krishnan, SG ;
Coste, JS ;
Walch, G .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (09) :1002-1012
[2]   Die arthroskopische Tenodese bei Schädigung der langen BizepssehneArthroscopic Tenodesis for Lesions of the Long Head of the Biceps [J].
Pascal Boileau ;
Lionel Neyton .
Operative Orthopädie und Traumatologie, 2005, 17 (6) :601-623
[3]  
Carey Paul, 2010, Orthopedics, V33, P23, DOI 10.3928/01477447-20091124-27
[4]   A Humerus Fracture in a Baseball Pitcher After Biceps Tenodesis [J].
Dein, Eric J. ;
Huri, Gazi ;
Gordon, John C. ;
McFarland, Edward G. .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2014, 42 (04) :877-879
[5]   Structural properties of a novel design of composite analogue humeri models [J].
Dunlap, James T. ;
Chong, Alexander C. M. ;
Lucas, George L. ;
Cooke, Francis W. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (11) :1922-1926
[6]   TORSIONAL STRENGTH REDUCTION DUE TO CORTICAL DEFECTS IN BONE [J].
EDGERTON, BC ;
AN, KN ;
MORREY, BF .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (06) :851-855
[7]   Composite Bone Models in Orthopaedic Surgery Research and Education [J].
Elfar, John J. ;
Menorca, Ron Martin Garcia ;
Reed, Jeffrey Douglas ;
Stanbury, Spencer .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (02) :111-120
[8]   Mechanical characterization of fourth generation composite humerus [J].
Grover, P. ;
Albert, C. ;
Wang, M. ;
Harris, G. F. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H12) :1169-1176
[9]   Minimally invasive proximal biceps tenodesis: an anatomical study for optimal placement and safe surgical technique [J].
Jarrett, Claudius D. ;
McClelland, Walter B., Jr. ;
Xerogeanes, John W. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (03) :477-480
[10]   Failure of Biceps Tenodesis With Interference Screw Fixation [J].
Koch, Benjamin Shay ;
Burks, Robert T. .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (05) :735-740