Tomographic diagnostic of the hydrogen beam from a negative ion source

被引:21
|
作者
Agostini, M. [1 ]
Brombin, M. [1 ]
Serianni, G. [1 ]
Pasqualotto, R. [1 ]
机构
[1] Assoc EURATOM ENEA Fus, Consorzio RFX, Padua, Italy
来源
PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS | 2011年 / 14卷 / 10期
关键词
NEUTRAL BEAMS; POSED PROBLEMS; LIMITED-DATA; L-CURVE; PERFORMANCE; JT-60U; SPECTROSCOPY; IMPROVEMENT; ALGORITHMS; SYSTEM;
D O I
10.1103/PhysRevSTAB.14.102801
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
In this paper the tomographic diagnostic developed to characterize the 2D density distribution of a particle beam from a negative ion source is described. In particular, the reliability of this diagnostic has been tested by considering the geometry of the source for the production of ions of deuterium extracted from an rf plasma (SPIDER). SPIDER is a low energy prototype negative ion source for the international thermonuclear experimental reactor (ITER) neutral beam injector, aimed at demonstrating the capability to create and extract a current of D(-) (H(-)) ions up to 50 A (60 A) accelerated at 100 kV. The ions are extracted over a wide surface (1: 52 x 0: 56 m(2)) with a uniform plasma density which is prescribed to remain within 10% of the mean value. The main target of the tomographic diagnostic is the measurement of the beam uniformity with sufficient spatial resolution and of its evolution throughout the pulse duration. To reach this target, a tomographic algorithm based on the simultaneous algebraic reconstruction technique is developed and the geometry of the lines of sight is optimized so as to cover the whole area of the beam. Phantoms that reproduce different experimental beam configurations are simulated and reconstructed, and the role of the noise in the signals is studied. The simulated phantoms are correctly reconstructed and their two-dimensional spatial nonuniformity is correctly estimated, up to a noise level of 10% with respect to the signal.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Tomographic reconstruction of the beam emissivity profile in the negative ion source NIO1
    Fonnesu, N.
    Agostini, M.
    Pasqualotto, R.
    Serianni, G.
    Veltri, P.
    NUCLEAR FUSION, 2016, 56 (12)
  • [2] Experimental research on beam current extraction of PIG negative hydrogen ion source for neutron tube
    Xin, Duqiang
    Zhao, Chenyi
    Xu, Qiang
    Qiao, Shuang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 903 : 147 - 151
  • [3] Experimental study on spatial uniformity of H- ion beam in a large negative ion source
    Hanada, M
    Seki, T
    Takado, N
    Inoue, T
    Morishita, T
    Mizuno, T
    Hatayama, A
    Imai, T
    Kashiwagi, M
    Sakamoto, K
    Taniguchi, M
    Watanabe, K
    FUSION ENGINEERING AND DESIGN, 2005, 74 (1-4) : 311 - 317
  • [4] H- beam extraction from a cesium seeded field effect transistor based radio frequency negative hydrogen ion source
    Ando, A.
    Matsuno, T.
    Funaoi, T.
    Tanaka, N.
    Tsumori, K.
    Takeiri, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
  • [5] The development of the radio frequency driven negative ion source for neutral beam injectors (invited)
    Kraus, W.
    Fantz, U.
    Franzen, P.
    Froeschle, M.
    Heinemann, B.
    Riedl, R.
    Wuenderlich, D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (02)
  • [6] Progress of the RF negative hydrogen ion source for fusion at HUST
    Zuo, Chen
    Chen, Peng
    LI, Zengshan
    Yang, Jinghan
    Song, Fei
    Chen, Dezhi
    PLASMA SCIENCE & TECHNOLOGY, 2022, 24 (12)
  • [7] Beam optics study of a negative ion source for neutral beam injection application at ASIPP
    Wei, Jiang-Long
    Liang, Li-Zhen
    Jiang, Cai-Chao
    Xie, Ya-Hong
    Hu, Chun-Dong
    Li, Jun
    Gu, Yu-Ming
    Chen, Yu-Qian
    Li, Jing-Yong
    Wu, Ming-Shan
    FUSION ENGINEERING AND DESIGN, 2017, 117 : 93 - 99
  • [8] Proton beam simulation of duoplasmatron ion source for diagnostic neutral beam of Alborz tokamak
    Kazemi, M.
    Amrollahi, R.
    FUSION ENGINEERING AND DESIGN, 2018, 127 : 1 - 9
  • [9] Effects of Negative Ion Source Characteristics on Beam Optics: The Case of SPIDER
    Veltri, P.
    Agostinetti, P.
    Serianni, G.
    Antoni, V.
    Cavenago, M.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (09) : 2279 - 2284
  • [10] The tomographic diagnostic of ITER neutral beam injector
    Brombin, M.
    Agostini, M.
    Dianin, C.
    Mattiolo, M.
    Pasqualotto, R.
    Serianni, G.
    Spizzo, G.
    NUCLEAR FUSION, 2013, 53 (05)