Simulation of electromagnetic fields caused by a lightning strike on the Gaisberg and the comparison of the results with ALDIS sensor measurements

被引:0
|
作者
Kohlmann, Hannes [1 ]
Schulz, Wolfgang [1 ]
Pichler, Hannes [1 ]
机构
[1] OVE ALDIS, Kahlenberger Str 2A, A-1190 Vienna, Austria
来源
ELEKTROTECHNIK UND INFORMATIONSTECHNIK | 2022年 / 139卷 / 03期
关键词
Lightning discharge; Electromagnetic fields; FDTD simulations; Lightning location system; ALDIS; Gaisberg; PROPAGATION; RIDGE;
D O I
10.1007/s00502-022-01028-x
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the results of electromagnetic field computations using the finite-difference time-domain (FDTD) method are presented. Specifically, the propagation of an electromagnetic field caused by a lightning event on the Gaisberg mountain (Salzburg, Austria) was simulated. To initialize the FDTD simulation domain, digital elevation model (DEM) data of the real propagation paths from the Gaisberg to seven different sensors of the lightning detection network ALDIS were used. To model the lightning channel, the MTLE (modified transmission line model with exponential decay) was applied, and the lightning current measured at the top of the tower, that is, at the base of the lightning channel, was used as the current source in the simulation. This way, the electromagnetic fields were simulated for the different propagation paths, and the resulting peak values of the magnetic (H) fields at the ALDIS sensor locations were compared with the values actually measured by the ALDIS sensors. The results of the 3D FDTD computations correlate well with the values actually recorded by the sensors for a given event, while the cylindrical symmetrical 2D FDTD simulation is not capable of reproducing the values measured. This can be explained by the fact that the complex terrain of the Alpine region with its reflections and diffraction phenomena in valleys and on mountain ridges cannot be represented accurately in 2D FDTD simulations. Furthermore, by using a set of sensor values from 54 (normalized) events, we were able to verify that a strike on top of a mountain can lead to higher values compared to a strike on flat terrain. This is due to the specific topography from the strike point in the given direction of propagation. In general, rough terrain like the Austrian Alps has an attenuating effect on the propagating electromagnetic fields.
引用
收藏
页码:335 / 343
页数:9
相关论文
共 50 条
  • [41] Magnetic fields from a scaled down model transmission line - Simulation and comparison to measurements
    Rahman, N. A.
    Hussain, H.
    Said, I.
    Jalal, T. S.
    Farag, A. S.
    APACE: 2005 ASIA-PACIFIC CONFERENCE ON APPLIED ELECTROMAGNETICS, PROCEEDINGS, 2005, : 147 - 151
  • [42] Comparison of measurements and simulation results in 300 mm CZ silicon crystal growth
    Gao Yu
    Tu Hailing
    Zhou Qigang
    Dai Xiaolin
    Xiao Qinghua
    RARE METALS, 2007, 26 (06) : 607 - 610
  • [43] Comparison of measurements and simulation results of dose for the flash radiation therapy beamline at PITZ
    Amirkhanyan, Z.
    Aftab, N.
    Adhikari, G.
    Boonpornprasert, P.
    Georgiev, G.
    Grebinyk, A.
    Gross, M.
    Hoffmann, A.
    Krasilnikov, M.
    Kuhl, T.
    Li, X. K.
    Oppelt, A.
    Philipp, S.
    Riemer, F.
    Richard, C.
    Vashchenko, G.
    Stephan, F.
    Khachatryan, V
    IPAC23 PROCEEDINGS, 2024, 2687
  • [44] Simultaneous measurements of electric-field pulses and radio reflections from lightning and experimental test of the results of numerical simulation
    Dubovoi, EI
    IZVESTIYA AKADEMII NAUK FIZIKA ATMOSFERY I OKEANA, 1997, 33 (01): : 122 - 131
  • [45] Lightning Electromagnetic Pulse Simulation Using 3D-FDTD Method (Comparison between PEC and UPLM Boundary Conditions)
    Arzag, K.
    Azzouz, Z.
    Ghemri, B.
    2016 33RD INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2016,
  • [46] Comparison of laboratory measurements on an EDFA with simulation results obtained using EDFA_Design®
    Baraniecki, TP
    Kozak, MM
    Unrau, UB
    Pawlik, EM
    Abramski, KM
    ICTON 2001: 3RD INTERNATIONAL CONFERENCE ON TRANSPARENT OPTICAL NETWORKS, CONFERENCE PROCEEDINGS, 2001, : 308 - 311
  • [47] Millimetre-wave channel impulse response measurements and comparison with raytracing simulation results
    Dinis, M
    Garcia, J
    Monteiro, V
    Oliveira, N
    13TH IEEE INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR AND MOBILE RADIO COMMUNICATIONS, VOL 1-5, PROCEEDINGS: SAILING THE WAVES OF THE WIRELESS OCEANS, 2002, : 463 - 467
  • [48] SIMULATION OF THE ENERGY BUDGET OF AN URBAN CANYON .2. COMPARISON OF MODEL RESULTS WITH MEASUREMENTS
    MILLS, GM
    ARNFIELD, AJ
    ATMOSPHERIC ENVIRONMENT PART B-URBAN ATMOSPHERE, 1993, 27 (02): : 171 - 181
  • [50] Design and Comparison of Digital Control Loops Analytical Models, Laboratory Measurements, and Simulation Results
    Cooke, Philip
    Wilson, Thomas G., Jr.
    Samsi, Rohan
    2010 TWENTY-FIFTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2010, : 183 - 187