Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures

被引:31
|
作者
Zhang, Yin-shun [1 ]
Zhang, Jian-xiang [1 ]
Yang, Qing-guo [1 ]
Li, Wei [1 ]
Tao, Hui [1 ]
Shen, Cai-liang [1 ]
机构
[1] Anhui Med Univ, Dept Orthopaed, Affiliated Hosp 1, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
关键词
Atlas fractures; C1; fractures; Jefferson fractures; Open reduction and internal fixation (ORIF); Osteosynthesis; Transverse atlantal ligament; JEFFERSON FRACTURES; ATLAS FRACTURES; BIOMECHANICAL ANALYSIS; PRESERVING REDUCTION; FIXATION; LIGAMENT; CLASSIFICATION; CONSTRUCT;
D O I
10.1016/j.spinee.2017.06.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Surgical treatment for unstable atlas fractures has evolved in recent decades from C1-C2 or C0-C2 fusion to motion-preservation techniques of open reduction and internal fixation (ORIF). However, regardless of a transoral or a posterior approach, the reduction is still not satisfactory. PURPOSE: The article describes and evaluates a new technique for treating unstable atlas fractures by using a monoaxial screw-rod system. STUDY DESIGN: This is a retrospective study. PATIENT SAMPLE: The sample includes adult patients with unstable C1 fractures treated with a posterior monoaxial screw-rod system. OUTCOME MEASURES: The outcome measures included a visual analog pain scale, radiographic reduction (lateral mass displacement [LMD]), maintenance of reduction, C1-C2 instability (anterior atlantodens interval), and complications. MATERIALS AND METHODS: From August 2013 to May 2016, nine consecutive patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with posterior ORIF by using a monoaxial screw-rod system. The medical records and the preoperative and postoperative radiographs were reviewed. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the reduction. RESULTS: All nine patients with a mean age of 50.3 years successfully underwent surgery with this technique, and a follow-up of 17.4 +/- 9.3 months was performed. Transverse atlantal ligament (TAL) injury was found in eight of the nine patients: one of type I and seven of type II. The preoperative LMD averaged 7.0 +/- 2.2 mm and was restored completely after surgery; all the fractures achieved bony healing without loss of reduction or implant failure. None of the patients had complications of neurologic deficit, vertebral artery injury, or wound infection associated with the surgical procedure. Two patients complained of greater occipital nerve neuralgia after the operation, which gradually disappeared in 1 month. All patients had a well-preserved range of motion of the upper cervical spine at the final follow-up. CONCLUSIONS: Posterior osteosynthesis with a monoaxial screw-rod system is capable of an almost anatomical reduction for the unstable atlas fractures. The TAL incompetence may not be a contraindication to ORIF for C1 fractures, but the long-term effect of C1-C2 instability remains to be further investigated. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 50 条
  • [31] C1 Lateral Mass-C2 Pedicle Screws and Crosslink Compression Fixation for Unstable Atlas Fracture
    Tan, Jun
    Li, Lijun
    Sun, Guixin
    Qian, Lie
    Yang, Mingjie
    Zeng, Cheng
    Teng, Honglin
    Jia, Lianshun
    SPINE, 2009, 34 (23) : 2505 - 2509
  • [32] Computed tomographic morphometric analysis of lateral inclination C1 pedicle screw for atlantoaxial instability patients with a narrow C1 posterior arch
    Zhang, Lei
    Wang, Huan
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2018, 34 (12) : 700 - 704
  • [33] Anatomic Determination of Optimal Entry Point and Direction For C1 Lateral Mass Screw Placement
    Blagg, Stuart E.
    Don, Angus S.
    Robertson, Peter A.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (04): : 233 - 239
  • [34] Giant delayed pseudo-aneurysm following screw placement in C1 lateral mass
    Guo, S.
    Pan, J.
    Li, L.
    Yang, M.
    Han, Y.
    Wen, J.
    Fan, M.
    Tan, J.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (06) : 691 - 694
  • [35] Modified C1 lateral mass screw insertion using a high entry point to avoid postoperative occipital neuralgia
    Lee, Sun-Ho
    Kim, Eun-Sang
    Eoh, Whan
    JOURNAL OF CLINICAL NEUROSCIENCE, 2013, 20 (01) : 162 - 167
  • [36] The Comparison Between Transarticular Screw Fixation and Segmental Screw-Rod Fixation for Posterior Fusion of the C1-2 Segment: A Systematic Review and Meta-Analysis
    Chang, Min Cheol
    Seok, Hyun-Gyu
    Choo, Yoo Jin
    Lee, Gun Woo
    WORLD NEUROSURGERY, 2022, 164 : E1007 - E1014
  • [37] Solitary C1 Posterior Fixation for Unstable Isolated Atlas Fractures: Case Report and Systematic Review of the Literature
    Bednar, Drew A.
    Almansoori, Khaled A.
    GLOBAL SPINE JOURNAL, 2016, 6 (04) : 375 - 382
  • [38] Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement
    Yeom, Jin S.
    Buchowski, Jacob M.
    Park, Kun-Woo
    Chang, Bong-Soon
    Lee, Choon-Ki
    Riew, K. Daniel
    SPINE JOURNAL, 2009, 9 (07) : 574 - 579
  • [39] Treatment of unstable C1 semi-ring fractures with direct C1 pedicle screw fixation using a navigational template: A case report and literature review
    Dong, Wei-Xin
    Chu, Zhen-Tao
    Hu, Yong
    MEDICINE, 2023, 102 (20) : E33800
  • [40] Computer-aided analysis for optimal screw insertion in lateral mass of C1: An anatomical study
    Krassnig, Renate
    Orlandi, Jakob Andrea
    Tackner, Ellen
    Hohenberger, Gloria
    Puchwein, Paul
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (06) : 817 - 822