Posterior osteosynthesis with monoaxial lateral mass screw-rod system for unstable C1 burst fractures

被引:34
作者
Zhang, Yin-shun [1 ]
Zhang, Jian-xiang [1 ]
Yang, Qing-guo [1 ]
Li, Wei [1 ]
Tao, Hui [1 ]
Shen, Cai-liang [1 ]
机构
[1] Anhui Med Univ, Dept Orthopaed, Affiliated Hosp 1, 218 Jixi Rd, Hefei 230022, Anhui, Peoples R China
关键词
Atlas fractures; C1; fractures; Jefferson fractures; Open reduction and internal fixation (ORIF); Osteosynthesis; Transverse atlantal ligament; JEFFERSON FRACTURES; ATLAS FRACTURES; BIOMECHANICAL ANALYSIS; PRESERVING REDUCTION; FIXATION; LIGAMENT; CLASSIFICATION; CONSTRUCT;
D O I
10.1016/j.spinee.2017.06.029
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Surgical treatment for unstable atlas fractures has evolved in recent decades from C1-C2 or C0-C2 fusion to motion-preservation techniques of open reduction and internal fixation (ORIF). However, regardless of a transoral or a posterior approach, the reduction is still not satisfactory. PURPOSE: The article describes and evaluates a new technique for treating unstable atlas fractures by using a monoaxial screw-rod system. STUDY DESIGN: This is a retrospective study. PATIENT SAMPLE: The sample includes adult patients with unstable C1 fractures treated with a posterior monoaxial screw-rod system. OUTCOME MEASURES: The outcome measures included a visual analog pain scale, radiographic reduction (lateral mass displacement [LMD]), maintenance of reduction, C1-C2 instability (anterior atlantodens interval), and complications. MATERIALS AND METHODS: From August 2013 to May 2016, nine consecutive patients with unstable atlas fractures were retrospectively reviewed. All patients were treated with posterior ORIF by using a monoaxial screw-rod system. The medical records and the preoperative and postoperative radiographs were reviewed. Preoperative and postoperative computed tomography scans were used to specify the fracture types and to assess the reduction. RESULTS: All nine patients with a mean age of 50.3 years successfully underwent surgery with this technique, and a follow-up of 17.4 +/- 9.3 months was performed. Transverse atlantal ligament (TAL) injury was found in eight of the nine patients: one of type I and seven of type II. The preoperative LMD averaged 7.0 +/- 2.2 mm and was restored completely after surgery; all the fractures achieved bony healing without loss of reduction or implant failure. None of the patients had complications of neurologic deficit, vertebral artery injury, or wound infection associated with the surgical procedure. Two patients complained of greater occipital nerve neuralgia after the operation, which gradually disappeared in 1 month. All patients had a well-preserved range of motion of the upper cervical spine at the final follow-up. CONCLUSIONS: Posterior osteosynthesis with a monoaxial screw-rod system is capable of an almost anatomical reduction for the unstable atlas fractures. The TAL incompetence may not be a contraindication to ORIF for C1 fractures, but the long-term effect of C1-C2 instability remains to be further investigated. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 23 条
[1]   Posterior Osteosynthesis of the Atlas for Nonconsolidated Jefferson Fractures A New Surgical Technique [J].
Abeloos, Laurence ;
De Witte, Olivier ;
Walsdorff, Michel ;
Delpierre, Isabelle ;
Bruneau, Michael .
SPINE, 2011, 36 (20) :E1360-E1363
[2]  
Böhm H, 2006, UNFALLCHIRURG, V109, P754, DOI 10.1007/s00113-006-1081-x
[3]   Primary Internal Fixation of Unilateral C1 Lateral Mass Sagittal Split Fractures A Series of 3 Cases [J].
Bransford, Richard ;
Chapman, Jens R. ;
Bellabarba, Carlo .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (03) :157-163
[4]   Injuries involving the transverse atlantal ligament: Classification and treatment guidelines based upon experience with 39 injuries [J].
Dickman, CA ;
Greene, KA ;
Sonntag, VKH .
NEUROSURGERY, 1996, 38 (01) :44-50
[5]   Long-term health-related quality of life outcomes following Jefferson-type burst fractures of the atlas [J].
Dvorak, MF ;
Johnson, MG ;
Boyd, M ;
Johnson, G ;
Kwon, BK ;
Fisher, CG .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (04) :411-417
[6]   Biomechanical analysis of atlas fractures - A study on 40 human atlas specimens [J].
Gebauer, Matthias ;
Goetzen, Nils ;
Barvencik, Florian ;
Beil, Frank Timo ;
Rupprecht, Martin ;
Rueger, Johannes M. ;
Pueschel, Klaus ;
Morlock, Michael ;
Amling, Michael .
SPINE, 2008, 33 (07) :766-770
[7]   Self-designed posterior atlas polyaxial lateral mass screw-plate fixation for unstable atlas fracture [J].
He, Baorong ;
Yan, Liang ;
Zhao, Qinpeng ;
Chang, Zhen ;
Hao, Dingjun .
SPINE JOURNAL, 2014, 14 (12) :2892-2896
[8]  
HELLER JG, 1993, J SPINAL DISORD, V6, P162
[9]  
Hu Y, 2014, J SPINAL DISORD TECH, V27, pE219, DOI 10.1097/BSD.0b013e31829a36c5
[10]   Unstable Jefferson fractures: Results of transoral osteosynthesis [J].
Hu, Yong ;
Albert, Todd J. ;
Kepler, Christopher K. ;
Ma, Wei-Hu ;
Yuan, Zhen-Shan ;
Dong, Wei-Xin .
INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (02) :145-151