Percutaneous device closure of pediatirc patent ductus arteriosus through femoral artery guidance by transthoracic echocardiography without radiation and contrast agents

被引:8
作者
Ye, Zankai [1 ]
Li, Zhiqiang [1 ]
Yi, Hanlu [1 ]
Zhu, Yaobin [1 ]
Sun, Yan [2 ]
Li, Pei [2 ]
Ma, Ning [2 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Cardiac Surg, Beijing 100045, Peoples R China
[2] Capital Med Univ, Beijing Childrens Hosp, Natl Ctr Childrens Hlth, Dept Echocardiog, Beijing 100045, Peoples R China
关键词
Transthoracic echocardiography; Patent ductus arteriosus; Percutaneous; Device closure; TRANSCATHETER CLOSURE; OCCLUSION; FEASIBILITY; FLUOROSCOPY;
D O I
10.1186/s13019-020-01119-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background For many years, percutaneous interventional occlusion of congenital patent ductus arteriosus (PDA) has been completed using radiation and contrast agents. In this study, transthoracic echocardiography without radiation and contrast agents was used to complete percutaneous occlusion of pediatric PDA. Methods Thirty-two children (8 males and 24 females) with normal heart function and no other intracardiac deformities were diagnosed with PDA (20 funnel type; 12 tube type), One patient had peripheral facial paralysis, 1 patient had epilepsy, and 1 case had multiple cervical deformities. All procedures were performed in the surgical operating room (without Digital Subtraction Angiography (DSA) equipment) under basic anesthesia through the femoral artery pathway. The procedures were guided by transthoracic echocardiography (TTE) by establishing an orbit with a catheter through the femoral artery to thepatent ductus arteriosus,pulmonary artery and right ventricle. A suitable ventricular septal defect occluder was placed using the femoral artery approach,and the treatment effect was evaluated by echocardiography after occlusion. The Outpatient follow-up was performed at 1, 3 months after the operation. Results All cases had successful closure of PDA, which took only 35.6 +/- 6.4 min. The diameter of the device was 4.8 +/- 2.3 mm, and the heart murmur disappeared. There was no shunt between the left pulmonary artery and the descending aortic artery, and the length of hospitalization was 3.4 +/- 0.5 days. No other incisions were needed in 32 cases. No occluder was removed, and no residual shunt was found after operation; moreover, no ICU stay was needed, and the mean hospital stay was 3.4 +/- 0.5 days. No residual shunt was found at the 1-, 3-month follow-up visit. Conclusions PDA closure guided by transthoracic echocardiography via femoral artery puncture is a minimally invasive procedure that avoids injuries due to radiation and contrast agents. This method has wider application prospects in pediatrics.
引用
收藏
页数:6
相关论文
共 18 条
  • [1] The efficacy and safety of the Amplatzer ductal occluder in young children and infants
    Al-Ata, J
    Arfi, AM
    Hussain, A
    Kouatli, AA
    Jalal, MO
    [J]. CARDIOLOGY IN THE YOUNG, 2005, 15 (03) : 279 - 285
  • [2] Patient Skin Reactions From Interventional Fluoroscopy Procedures
    Balter, Stephen
    Miller, Donald L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W335 - W342
  • [3] BAMTEAU AE, 2014, ARCH CARDIOVASC DIS, V107, P122
  • [4] Transcatheter Occlusion of the Patent Ductus Arteriosus in Infants: Experimental Testing of a New Amplatzer Device
    Bass, John L.
    Wilson, Neil
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 83 (02) : 250 - 255
  • [5] Transcatheter closure of persistent ductus arteriosus with the Amplatzer duct occluder in very young symptomatic children
    Butera, G
    De Rosa, G
    Chessa, M
    Piazza, L
    Delogu, A
    Frigiola, A
    Carminati, M
    [J]. HEART, 2004, 90 (12) : 1467 - 1470
  • [6] Cao H, 2018, ANATOL J CARDIOL, V20, P30, DOI [10.14744/AnatolJCardiol.2018.99001, 10.14744/AnatolJCardiol.2018.90001]
  • [7] Transthoracic Echocardiography as an Alternative Major Guidance to Angiography During Transcatheter Closure of Patent Ductus Arteriosus: Technical Feasibility and Clinical Relevance
    Chen, Wanhua
    Yan, Xiaoping
    Huang, Yu
    Sun, Xudong
    Zhong, Ling
    Li, Jinguo
    Chen, Hua
    Zhong, Huiying
    Chen, Lianglong
    [J]. PEDIATRIC CARDIOLOGY, 2015, 36 (01) : 14 - 19
  • [8] Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method
    Ewert, P
    Berger, F
    Daehnert, I
    van Wees, J
    Gittermann, M
    Abdul-Khaliq, H
    Lange, PE
    [J]. CIRCULATION, 2000, 101 (08) : 847 - 849
  • [9] Persistent Renal Damage After Contrast-Induced Acute Kidney Injury Incidence, Evolution, Risk Factors, and Prognosis
    Maioli, Mauro
    Toso, Anna
    Leoncini, Mario
    Gallopin, Michela
    Musilli, Nicola
    Bellandi, Francesco
    [J]. CIRCULATION, 2012, 125 (25) : 3099 - +
  • [10] Radiation Risks From Cardiovascular Imaging Tests
    Meinel, Felix G.
    Nance, John W., Jr.
    Harris, Brett S.
    De Cecco, Carlo N.
    Costello, Philip
    Schoepf, U. Joseph
    [J]. CIRCULATION, 2014, 130 (05) : 442 - 445