With or Without Residual C-Peptide, Patients with Type 2 Diabetes Realize Glycemic Benefits from Real-Time Continuous Glucose Monitoring

被引:1
|
作者
Bailey, Ryan [1 ]
Calhoun, Peter [1 ]
Chao, Christy [2 ]
Walker, Tomas C. [2 ]
机构
[1] Jaeb Ctr Hlth Res, Tampa, FL USA
[2] Dexcom Inc, 6340 Sequence Dr, San Diego, CA 92121 USA
关键词
Continuous glucose monitoring; Type; 2; diabetes; C-peptide; Glycemic control; HbA1c; Time in range;
D O I
10.1089/dia.2021.0384
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Real-time continuous glucose monitoring (RT-CGM) is superior to blood glucose monitoring (BGM) for adults with insulin-treated type 2 diabetes (T2D); however, the utility of C-peptide levels for predicting the magnitude of the glycemic benefits is controversial. Data were from a subset of 147 participants in the MOBILE study who were treated with basal-only insulin and who had baseline C-peptide levels >= 0.5 ng/mL. Participants were randomized to treatment with either RT-CGM (n = 100) or BGM (n = 47). Between-group differences in hemoglobin A1c (HbA1c) and time in range (TIR) changes were assessed. The between-group difference in HbA1c favored the RT-CGM group (by 0.58 percentage points, P = 0.004 at 3 months and by 0.42 percentage points, P = 0.04 at 8 months). TIR was 16% higher, and time >180 mg/dL was 16% lower, in the RT-CGM group at 8 months (P = 0.002 for each). In T2D managed with basal insulin, RT-CGM benefits occur for those with residual insulin secretory capacity. Clinical Trial Identifier: NCT03566693
引用
收藏
页码:281 / 284
页数:4
相关论文
共 50 条
  • [21] C-peptide concentrations in patients with type 2 diabetes treated with insulin
    Uzunlulu, Mehmet
    Oguz, Aytekin
    Bahadir, Muzeyyen Arslan
    Erbakan, Ayse Naciye
    Keskinler, Mirac Vural
    Mesci, Banu Alpaslan
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2019, 13 (06) : 3099 - 3104
  • [22] The effect of do-it-yourself real-time continuous glucose monitoring on psychological and glycemic variables in children with type 1 diabetes: A randomized crossover trial
    Elbalshy, Mona M.
    Styles, Sara
    Haszard, Jillian J.
    Galland, Barbara C.
    Crocket, Hamish
    Jefferies, Craig
    Wiltshire, Esko
    Tomlinson, Paul
    de Bock, Martin, I
    Wheeler, Benjamin J.
    PEDIATRIC DIABETES, 2022, 23 (04) : 480 - 488
  • [23] Real-Time Continuous Glucose Monitoring Benefits Glycemic Control in Adolescents and Young Adults With Type 1 Diabetes Irrespective of Insulin Delivery Modality: Subanalysis of the MILLENNIAL Study
    Teoh, Ik Hur
    Prabhu, Joshi
    Mubita, Womba
    Azmi, Shazli
    Urwin, Andrea
    Doughty, Ian
    Leelarathna, Lalantha
    Thabit, Hood
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (01): : 252 - 253
  • [24] Assessment of factors associated with improved glycemic control after switching from intermittently scanned to real-time continuous glucose monitoring in Japanese patients with type 1 diabetes
    Yamada, Eijiro
    Nakajima, Yasuyo
    Horiguchi, Kazuhiko
    Okada, Shuichi
    Yamada, Masanobu
    ENDOCRINE JOURNAL, 2023, 70 (12) : 1187 - 1193
  • [25] Tolerability and acceptability of real-time continuous glucose monitoring and its impact on diabetes management behaviours in individuals with Type 2 Diabetes - A pilot study
    Taylor, P. J.
    Thompson, C. H.
    Luscombe-Marsh, N. D.
    Wycherley, T. P.
    Wittert, G.
    Brinkworth, G. D.
    Zajac, I.
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2019, 155
  • [26] The Impact of Physical Activity on Glycemic Variability Assessed by Continuous Glucose Monitoring in Patients With Type 2 Diabetes Mellitus: A Systematic Review
    Bennetsen, Sebastian L.
    Feineis, Camilla S.
    Legaard, Grit E.
    Lyngbaek, Mark P. P.
    Karstoft, Kristian
    Ried-Larsen, Mathias
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [27] Glycemic Outcomes with Early Initiation of Continuous Glucose Monitoring System in Recently Diagnosed Patients with Type 1 Diabetes
    Mulinacci, Giacomo
    Alonso, G. Todd
    Snell-Bergeon, Janet K.
    Shah, Viral N.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (01) : 6 - 10
  • [28] Healthcare Utilization, Costs, and Adverse Events of Real-Time Continuous Glucose Monitoring versus Traditional Blood Glucose Monitoring Among US Adults with Type 1 Diabetes
    Wong, Benjamin
    Deng, Yalin
    Rascati, Karen L.
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (06): : 1393 - 1400
  • [29] Significance of "Time below Range" as a Glycemic Marker Derived from Continuous Glucose Monitoring in Japanese Children and Adolescents with Type 1 Diabetes
    Urakami, Tatsuhiko
    Yoshida, Kei
    Kuwabara, Remi
    Mine, Yusuke
    Aoki, Masako
    Suzuki, Junichi
    Morioka, Ichiro
    HORMONE RESEARCH IN PAEDIATRICS, 2020, 93 (04): : 251 - 257
  • [30] Association between Real-Time Continuous Glucose Monitor Use and Diabetes-Related Medical Costs for Patients with Type 2 Diabetes
    Norman, Gregory J.
    Paudel, Misti L.
    Parkin, Christopher G.
    Bancroft, Tim
    Lynch, Peter M.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (07) : 520 - 524