Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis

被引:0
|
作者
Kessler-Liechti, Gerda [1 ]
Zix, Juergen [2 ]
Mericske-Stern, Regina [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept Cranio Maxillofacial Surg, Univ Hosp Bern, Bern, Switzerland
关键词
implant stability; mandible; 1-stage implants; resonance frequency analysis;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. Materials and Methods: Stability measurements by means of RFA were performed in regularly followed patients who had received 1-stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P < .0125). Results: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. Conclusions: A mean ISQ of 64.5 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [41] Resonance frequency analysis of implants in the guinea pig model: Influence of boundary conditions and orientation of the transducer
    Pattijn, V.
    Jaecques, S. V. N.
    De Smet, E.
    Muraru, L.
    Van Lierde, C.
    Van der Perre, G.
    Naert, I.
    Sloten, J. Vander
    MEDICAL ENGINEERING & PHYSICS, 2007, 29 (02) : 182 - 190
  • [42] Secondary stability assessment of titanium implants with an alkali-etched surface: A resonance frequency analysis study in beagle dogs
    Strnad, Jakub
    Urban, Karel
    Povysil, Ctibor
    Strnad, Zdenek
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (03) : 502 - 512
  • [43] Identifiable range of osseointegration of dental implants through resonance frequency analysis
    Wang, S.
    Liu, G. R.
    Hoang, K. C.
    Guo, Y.
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (10) : 1094 - 1106
  • [44] Resonance frequency analysis of dental implants in patients with vitamin D deficiency
    Toy, Vesile Elif
    Sabanci, Arife
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (12)
  • [45] A prospective case-control clinical trial comparing 1-and 2-stage Nobel Biocare TiUnite implants: Resonance frequency analysis assessed by Osstell Mentor during integration
    Tallarico, Marco
    Vaccarella, Anna
    Marzi, Gian Carlo
    Alviani, Alessia
    Campana, Valentina
    QUINTESSENCE INTERNATIONAL, 2011, 42 (08): : 635 - 644
  • [46] Longitudinal Implant Stability Measurements Based on Resonance Frequency Analysis After Placement in Healed or Regenerated Bone
    Deli, Giorgio
    Petrone, Vincenzo
    De Risi, Valeria
    Tadic, Drazen
    Zafiropoulos, Gregory-George
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) : 438 - 447
  • [47] Parameters of Implant Stability Measurements Based on Resonance Frequency and Damping Capacity: A Comparative Finite Element Analysis
    Winter, Werner
    Moehrle, Stefan
    Holst, Stefan
    Karl, Matthias
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 532 - 539
  • [48] Assessment of the Primary Stability of Dental Implants in Artificial Bone Using Resonance Frequency and Percussion Analyses
    Ahmad, Omaid K.
    Kelly, Robert
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (01) : 89 - 95
  • [49] Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study
    Lee, Jungwon
    Pyo, Se-Wook
    Cho, Hyun-Jae
    An, Jung-Sub
    Lee, Jae-Hyun
    Koo, Ki-Tae
    Lee, Yong-Moo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01) : 56 - 66
  • [50] Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides
    Sul, YT
    Johansson, CB
    Jeong, Y
    Wennerberg, A
    Albrektsson, T
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) : 252 - 259