Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis

被引:0
|
作者
Kessler-Liechti, Gerda [1 ]
Zix, Juergen [2 ]
Mericske-Stern, Regina [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept Cranio Maxillofacial Surg, Univ Hosp Bern, Bern, Switzerland
关键词
implant stability; mandible; 1-stage implants; resonance frequency analysis;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. Materials and Methods: Stability measurements by means of RFA were performed in regularly followed patients who had received 1-stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P < .0125). Results: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. Conclusions: A mean ISQ of 64.5 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [31] Influence of implant dimensions and position on primary and secondary stability: a prospective clinical study in the mandible using resonance frequency analysis
    Rengo, C.
    Nappo, A.
    Pantaleo, G.
    Spagnuolo, G.
    Ferrari, M.
    JOURNAL OF OSSEOINTEGRATION, 2020, 12 (01) : 34 - 38
  • [32] Repeatability of the resonance frequency analysis values in implants with a new technology
    Carmen Diaz-Castro, Ma
    Falcao, Artur
    Lopez-Jarana, Paula
    Falcao, Carlos
    Rios-Santos, Jose-Vicente
    Fernandez-Palacin, Ana
    Herrero-Climent, Mariano
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (05): : E636 - E642
  • [33] Resonance frequency analysis of implants placed with osteotome sinus floor elevation in posterior maxillae
    Qian, Shu-Jiao
    Gu, Ying-Xin
    Mo, Jia-Ji
    Qiao, Shi-Chong
    Zhuang, Long-Fei
    Lai, Hong-Chang
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (01) : 113 - 119
  • [34] Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading -: Successful vs. failing implants
    Glauser, R
    Sennerby, L
    Meredith, N
    Rée, A
    Lundgren, A
    Gottlow, J
    Hämmerle, CHF
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) : 428 - 434
  • [35] Resonance frequency analysis of one-stage dental implant stability during the osseointegration period
    Ersanli, S
    Karabuda, C
    Beck, F
    Leblebicioglu, B
    JOURNAL OF PERIODONTOLOGY, 2005, 76 (07) : 1066 - 1071
  • [36] Primary stability and bone deformation induced by tapered implants in different bone densities: a microtomography and resonance frequency analysis
    P. Faria
    A. Vieta
    F. A. Oliveira
    V. F. Carvalho
    S. L. S. Souza
    Mario Taba
    Periodontal and Implant Research, 9 (1)
  • [37] Mapping implant stability by resonance frequency analysis
    Meredith, N
    Rasmussen, L
    Sennerby, L
    Alleyne, D
    MEDICAL SCIENCE RESEARCH, 1996, 24 (03): : 191 - 193
  • [38] Resonance frequency analysis (RFA) and insertional torque (IT) stability comparisons of implants placed using osteotomes versus drilling techniques: A preliminary case study
    Xing, Yi
    Khandelwal, Namita
    Petrov, Sofia
    Drew, Howard J.
    Mupparapu, Mel
    QUINTESSENCE INTERNATIONAL, 2015, 46 (09): : 789 - 798
  • [39] A comparative study on the initial stability of different implants placed above the bone level using resonance frequency analysis
    Kang, In-Ho
    Kim, Chang-Whe
    Lim, Young-Jun
    Kim, Myung-Joo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (04) : 190 - 195
  • [40] Measurement of mini-implant stability using resonance frequency analysis
    Nienkemper, Manuel
    Wilmes, Benedict
    Panayotidis, Agamemnon
    Pauls, Alexander
    Golubovic, Vladimir
    Schwarz, Frank
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2013, 83 (02) : 230 - 238