Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis

被引:0
|
作者
Kessler-Liechti, Gerda [1 ]
Zix, Juergen [2 ]
Mericske-Stern, Regina [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Prosthodont, CH-3010 Bern, Switzerland
[2] Univ Bern, Dept Cranio Maxillofacial Surg, Univ Hosp Bern, Bern, Switzerland
关键词
implant stability; mandible; 1-stage implants; resonance frequency analysis;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. Materials and Methods: Stability measurements by means of RFA were performed in regularly followed patients who had received 1-stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P < .0125). Results: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. Conclusions: A mean ISQ of 64.5 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 50 条
  • [1] Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    Zix, J
    Kessler-Liechti, G
    Mericske-Stern, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (05) : 747 - 752
  • [2] Primary stability measurements of single implants in the midline of the edentulous mandible for overdentures
    Alsabeeha, Nabeel H. M.
    De Silva, Rohana K.
    Thomson, W. Murray
    Payne, Alan G. T.
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (05) : 563 - 566
  • [3] Stability Measurements of Craniofacial Implants by Means of Resonance Frequency Analysis: 1-Year Clinical Pilot Study
    Karakoca-Nemli, Secil
    Aydin, Cemal
    Yilmaz, Handan
    Sarisoy, Senol
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (01) : 187 - 193
  • [4] Predictability of the resonance frequency analysis in the survival of dental implants placed in the anterior non-atrophied edentulous mandible
    Gonzalez-Garcia, Raul
    Monje, Florencio
    Moreno-Garcia, Carlos
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2011, 16 (05): : E664 - E669
  • [5] Stability measurements of one-stage Branemark implants during healing in mandibles -: A clinical resonance frequency analysis study
    Friberg, B
    Sennerby, L
    Linden, B
    Gröndahl, K
    Lekholm, U
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 28 (04) : 266 - 272
  • [6] Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study
    Gulay, Gulsah
    Asar, Neset Volkan
    Tulunoglu, Ibrahim
    Turkyilmaz, Ilser
    Wang, Hom-Lay
    Tozum, Tolga F.
    IMPLANT DENTISTRY, 2012, 21 (06) : 461 - 466
  • [7] Implant Stability Measurements of Two Immediate Loading Protocols for the Edentulous Mandible: Rigid and Semi-rigid Splinting of the Implants
    Lee, Hyung Joo
    de Mattias Sartori, Ivete Aparecida
    Alcantara, Paola Rebelatto
    Vieira, Rogeria Acedo
    Suzuki, Dalton
    Kiatake Fontao, Flavia Gasparini
    Tiossi, Rodrigo
    IMPLANT DENTISTRY, 2012, 21 (06) : 486 - 490
  • [8] Resonance frequency measurements of implant stability in the dog mandible: experimental comparison with histomorphometric data
    Schliephake, H.
    Sewing, A.
    Aref, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (10) : 941 - 946
  • [9] Predicting osseointegration by means of implant primary stability - A resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants
    Nedir, R
    Bischof, M
    Szmukler-Moncler, S
    Bernard, JP
    Samson, J
    CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (05) : 520 - 528
  • [10] Use of resonance frequency analysis to evaluate the effects of surface properties on the stability of different implants
    Gursoytrak, Burcu
    Ataoglu, Hanife
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (03) : 239 - 245