Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis

被引:96
|
作者
Mitarai, S. [1 ]
Okumura, M. [2 ]
Toyota, E. [3 ]
Yoshiyama, T. [2 ]
Aono, A. [4 ]
Sejimo, A. [5 ]
Azuma, Y. [4 ]
Sugahara, K. [5 ]
Nagasawa, T. [5 ]
Nagayama, N. [3 ]
Yamane, A. [3 ]
Yano, R. [2 ]
Kokuto, H. [2 ]
Morimoto, K. [2 ]
Ueyama, M. [2 ]
Kubota, M. [2 ]
Yi, R. [2 ]
Ogata, H. [2 ]
Kudoh, S. [2 ]
Mori, T. [1 ]
机构
[1] JATA, Res Inst TB, Bacteriol Div, Dept Mycobacterium Reference & Res, Tokyo 2048533, Japan
[2] JATA, Double Barred Cross Hosp, Dept Resp & Internal Med, Tokyo 2048533, Japan
[3] Tokyo Hosp, Natl Hosp Org, Dept Resp & Internal Med, Tokyo, Japan
[4] JATA, Double Barred Cross Hosp, Microbiol Lab, Tokyo 2048533, Japan
[5] Tokyo Hosp, Natl Hosp Org, Microbiol Lab, Tokyo, Japan
关键词
LAMP; tuberculosis; diagnosis; POLYMERASE-CHAIN-REACTION; HUMAN-IMMUNODEFICIENCY-VIRUS; MYCOBACTERIA DIRECT ASSAY; PULMONARY TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL-EVALUATION; SPUTUM SAMPLES; RIFAMPIN RESISTANCE; DEVELOPING-COUNTRY; AMPLICOR MTB;
D O I
10.5588/ijtld.10.0629
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: A new loop-mediated isothermal amplification (LAMP) test kit, including a simple DNA extraction device for the detection of Mycobacterium tuberculosis complex, was developed for commercial use and evaluated for its usefulness in diagnosing tuberculosis (TB). DESIGN: The LAMP test was performed using untreated and N-acetyl-L-cysteine (NALC) NaOH-treated sputum specimen. The efficiency of the kit was compared with other conventional laboratory examinations, including other nucleic acid amplification (NAA) tests. RESULTS: The sensitivity of LAMP using raw sputum (direct LAMP) in smear- and culture-positive specimens was 98.2% (95% CI 94.9-99.4), while the sensitivity in smear-negative, culture-positive specimens was 55.6% (95% CI 43.4-68.0). The diagnostic sensitivity of direct LAMP for the diagnosis of individuals with TB was 88.2% (95% CI 81.4-92.7). The sensitivity values of direct LAMP were slightly, but not statistically significantly lower than those of Cobas Amplicor MTB and TRC Rapid MT, while the sensitivity of the LAMP test using NALC-NaOH treated sputum was significantly lower than other NAA tests (P < 0.05) for smear-negative, culture-positive specimens. The new commercial version of the LAMP kit was easy to handle and yielded results within 1 h of receiving sputum specimens. CONCLUSIONS: This test is considered a promising diagnostic tool for TB, even for peripheral laboratories with limited equipment, such as those in developing countries.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 50 条
  • [31] Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification
    Sanem Ayaz Kök
    Selcen Üstün
    Hümeyra Taşkent Sezgin
    Molecular Biotechnology, 2023, 65 : 1228 - 1241
  • [32] Loop-Mediated isothermal Amplification Methods for Diagnosis of Bacterial Meningitis
    Seki, Mitsuko
    Kilgore, Paul E.
    Kim, Eun Jin
    Ohnishi, Makoto
    Hayakawa, Satoshi
    Kim, Dong Wook
    FRONTIERS IN PEDIATRICS, 2018, 6
  • [33] Diagnosis of Ruminant Viral Diseases with Loop-Mediated Isothermal Amplification
    Kok, Sanem Ayaz
    Ustun, Selcen
    Sezgin, Humeyra Taskent
    MOLECULAR BIOTECHNOLOGY, 2023, 65 (08) : 1228 - 1241
  • [34] MALARIA DIAGNOSIS BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) IN THAILAND
    Ocker, Ronja
    Prompunjai, Yongyut
    Chutipongvivate, Salakchit
    Karanis, Panagiotis
    REVISTA DO INSTITUTO DE MEDICINA TROPICAL DE SAO PAULO, 2016, 58
  • [35] Loop-Mediated Isothermal Amplification in Schistosomiasis
    Garcia-Bernalt Diego, Juan
    Fernandez-Soto, Pedro
    Febrer-Sendra, Begona
    Crego-Vicente, Beatriz
    Muro, Antonio
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) : 1 - 13
  • [36] Loop-Mediated Isothermal Amplification for the Diagnosis of Sporotrichosis by Sporothrix brasiliensis
    Araujo, Marcella Donadel
    Poester, Vanice Rodrigues
    Schirmer, Helena
    Mattevi, Vanessa Sune
    Trapaga, Mariana Rodrigues
    Xavier, Melissa Orzechowski
    Teixeira, Marcus de Melo
    Almeida-Paes, Rodrigo
    Zancope-Oliveira, Rosely Maria
    Severo, Cecilia Bittencourt
    MYCOPATHOLOGIA, 2024, 189 (05)
  • [37] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis
    Sharma, Kusum
    Bansal, Reema
    Sharma, Aman
    Beke, Nikhil
    Gupta, Amod
    JAMA OPHTHALMOLOGY, 2014, 132 (06) : 777 - 778
  • [38] Loop-Mediated Isothermal Amplification for Rapid Diagnosis of Tubercular Uveitis
    Balne, Praveen Kumar
    Basu, Soumyava
    Sharma, Savitri
    JAMA OPHTHALMOLOGY, 2015, 133 (02) : 225 - 226
  • [39] Loop-mediated isothermal amplification of DNA
    Notomi, Tsugunori
    Okayama, Hiroto
    Masubuchi, Harumi
    Yonekawa, Toshihiro
    Watanabe, Keiko
    Amino, Nobuyuki
    Hase, Tetsu
    NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [40] Evaluation of three enzyme immunoassays and a loop-mediated isothermal amplification test for the laboratory diagnosis of Clostridium difficile infection
    Bruins, M. J.
    Verbeek, E.
    Wallinga, J. A.
    van Coppenraet, L. E. S. Bruijnesteijn
    Kuijper, E. J.
    Bloembergen, P.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (11) : 3035 - 3039