Evaluation of a simple loop-mediated isothermal amplification test kit for the diagnosis of tuberculosis

被引:96
|
作者
Mitarai, S. [1 ]
Okumura, M. [2 ]
Toyota, E. [3 ]
Yoshiyama, T. [2 ]
Aono, A. [4 ]
Sejimo, A. [5 ]
Azuma, Y. [4 ]
Sugahara, K. [5 ]
Nagasawa, T. [5 ]
Nagayama, N. [3 ]
Yamane, A. [3 ]
Yano, R. [2 ]
Kokuto, H. [2 ]
Morimoto, K. [2 ]
Ueyama, M. [2 ]
Kubota, M. [2 ]
Yi, R. [2 ]
Ogata, H. [2 ]
Kudoh, S. [2 ]
Mori, T. [1 ]
机构
[1] JATA, Res Inst TB, Bacteriol Div, Dept Mycobacterium Reference & Res, Tokyo 2048533, Japan
[2] JATA, Double Barred Cross Hosp, Dept Resp & Internal Med, Tokyo 2048533, Japan
[3] Tokyo Hosp, Natl Hosp Org, Dept Resp & Internal Med, Tokyo, Japan
[4] JATA, Double Barred Cross Hosp, Microbiol Lab, Tokyo 2048533, Japan
[5] Tokyo Hosp, Natl Hosp Org, Microbiol Lab, Tokyo, Japan
关键词
LAMP; tuberculosis; diagnosis; POLYMERASE-CHAIN-REACTION; HUMAN-IMMUNODEFICIENCY-VIRUS; MYCOBACTERIA DIRECT ASSAY; PULMONARY TUBERCULOSIS; RESPIRATORY SPECIMENS; CLINICAL-EVALUATION; SPUTUM SAMPLES; RIFAMPIN RESISTANCE; DEVELOPING-COUNTRY; AMPLICOR MTB;
D O I
10.5588/ijtld.10.0629
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
OBJECTIVE: A new loop-mediated isothermal amplification (LAMP) test kit, including a simple DNA extraction device for the detection of Mycobacterium tuberculosis complex, was developed for commercial use and evaluated for its usefulness in diagnosing tuberculosis (TB). DESIGN: The LAMP test was performed using untreated and N-acetyl-L-cysteine (NALC) NaOH-treated sputum specimen. The efficiency of the kit was compared with other conventional laboratory examinations, including other nucleic acid amplification (NAA) tests. RESULTS: The sensitivity of LAMP using raw sputum (direct LAMP) in smear- and culture-positive specimens was 98.2% (95% CI 94.9-99.4), while the sensitivity in smear-negative, culture-positive specimens was 55.6% (95% CI 43.4-68.0). The diagnostic sensitivity of direct LAMP for the diagnosis of individuals with TB was 88.2% (95% CI 81.4-92.7). The sensitivity values of direct LAMP were slightly, but not statistically significantly lower than those of Cobas Amplicor MTB and TRC Rapid MT, while the sensitivity of the LAMP test using NALC-NaOH treated sputum was significantly lower than other NAA tests (P < 0.05) for smear-negative, culture-positive specimens. The new commercial version of the LAMP kit was easy to handle and yielded results within 1 h of receiving sputum specimens. CONCLUSIONS: This test is considered a promising diagnostic tool for TB, even for peripheral laboratories with limited equipment, such as those in developing countries.
引用
收藏
页码:1211 / 1217
页数:7
相关论文
共 50 条
  • [21] Loop-mediated isothermal amplification (TB-lamp): a step forward in the diagnosis of tuberculosis?
    Saiyed, Hanieya
    Fatima, Sarosh
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2017, 67 (03) : 489 - 489
  • [22] Visual detection of mycobacterium tuberculosis by loop-mediated isothermal amplification
    Aryan, Ehsan
    Neshani, Alireza
    Sadeghian, Hamid
    Safdari, Hadi
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [23] Loop-mediated isothermal amplification with the Procedure for Ultra Rapid Extraction kit for the diagnosis of pneumocystis pneumonia
    Kawano, Shuichi
    Maeda, Takuya
    Suzuki, Takefumi
    Abe, Tatsuhiro
    Mikita, Kei
    Hamakawa, Yusuke
    Ono, Takeshi
    Sonehara, Wataru
    Miyahira, Yasushi
    Kawana, Akihiko
    JOURNAL OF INFECTION AND CHEMOTHERAPY, 2015, 21 (3-4) : 224 - 226
  • [24] Detection of Mycobacterium Tuberculosis by Loop-Mediated Isothermal Amplification Assay
    Ahn, Young-Chang
    Nam, Youn-Hyoung
    Park, Su-Min
    Cho, Min-Ho
    Seo, Jae-Won
    Yoon, Il-Kyu
    Park, Yong Hyun
    Jang, Won-Cheoul
    JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE, 2008, 52 (03): : 273 - 280
  • [25] Evaluation of WarmStart Colorimetric Loop-Mediated Isothermal Amplification Assay for Diagnosis of Malaria
    Lai, Meng Yee
    Ooi, Choo Huck
    Jaimin, Joel Judson
    Lau, Yee Ling
    AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2020, 102 (06): : 1370 - 1372
  • [26] Evaluation of a Loop-Mediated Isothermal Amplification Assay for Diagnosis of Clostridium difficile Infections
    Lalande, Valerie
    Barrault, Laurence
    Wadel, Sophie
    Eckert, Catherine
    Petit, Jean-Claude
    Barbut, Frederic
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (07) : 2714 - 2716
  • [27] Evaluation of Loop-mediated Isothermal Amplification Assay for Rapid Diagnosis of Acanthamoeba Keratitis
    Mewara, Abhishek
    Khurana, Sumeeta
    Yoonus, Shakila
    Megha, Kirti
    Tanwar, Parveen
    Gupta, Amit
    Sehgal, Rakesh
    INDIAN JOURNAL OF MEDICAL MICROBIOLOGY, 2017, 35 (01) : 90 - 94
  • [28] Development and evaluation of a loop-mediated isothermal amplification method for diagnosis of tropical theileriosis
    Salih, D. A.
    Liu, Z.
    Bakheit, M. A.
    Ali, A. M.
    El Hussein, A. M.
    Unger, H.
    Viljoen, G.
    Seitzer, U.
    Ahmed, J. S.
    TRANSBOUNDARY AND EMERGING DISEASES, 2008, 55 (5-6) : 238 - 243
  • [29] Evaluation of the Loopamp® (loop-mediated isothermal amplification) kit for detecting Norovirus RNA in faecal samples
    Iturriza-Gomara, Miren
    Xerry, Jaqueline
    Gallimore, Chris I.
    Dockery, Clare
    Gray, Jim
    JOURNAL OF CLINICAL VIROLOGY, 2008, 42 (04) : 389 - 393
  • [30] Evaluation of loop-mediated isothermal amplification test kit (tb-lamp) for the diagnostic of pulmonary tuberculosis in a tertiary hospital in iloilo city: A retrospective study
    Tabuena, Rollin
    Landong, Jiggy Leonard
    Alcantara, Earl
    Tabuena, Ma. Daisy
    Anayan, Ma. Theresa Crisanta
    RESPIROLOGY, 2023, 28 : 243 - 243