Combining liquid chromatography with MALDI mass spectrometry using a heated droplet interface

被引:48
|
作者
Zhang, BY [1 ]
McDonald, C [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac034934s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel interfacing technology is described to combine solution-based separation techniques such as liquid chromatography (LC) with matrix-assisted laser desorption ionization (MALDI) mass spectrometry. The interface includes a transfer tube having an inlet and an outlet, the inlet being adapted to accept the LC effluents and the outlet being adapted to form continuously replaced, hanging droplets of the liquid stream, and a MALDI sample plate mounted below the outlet of the transfer tube for collecting the droplets. The liquid stream in the transfer tube is heated to a temperature sufficient to cause partial evaporation of the carrier solvent from the hanging droplets. The droplets are dislodged to the MALDI plate, which is heated to above the boiling point of the carrier solvent to cause further evaporation of the carrier solvent from the collected droplets. It is found that analytes can be fractionated and deposited to a sample spot of 0.8 mm in diameter when a liquid flow rate of up to 50 muL/min and a fractionation interval of 1 min/spot are used. Flow rate of up to 200 muL/min can be used with a deposition sample spot of 2.4 mm in diameter on a commercial MALDI target. This heated droplet interface does not introduce sample loss, and the detection sensitivity of LC/MALDI is similar to that of standard MALDI, i.e., low femtomoles for peptide analysis with a microliter sample deposition. It is compatible with microbore and narrowbore column separation, thus allowing the injection of a larger amount of sample for separation and analysis, compared to a capillary column LC/MALDI system. The detection dynamic range is shown to be in the order of 106 for peptide mixture analysis, which is 4 orders of magnitude greater than standard MALDI. The application of this interface for combining LC with MALDI MS/MS is demonstrated in the proteome analysis of water-soluable protein components of E. coli K12 extracts.
引用
收藏
页码:992 / 1001
页数:10
相关论文
共 50 条
  • [11] THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BLAKLEY, CR
    VESTAL, ML
    ANALYTICAL CHEMISTRY, 1983, 55 (04) : 750 - 754
  • [12] Analysis of modified polyamide 6.6 using coupled liquid chromatography and MALDI-TOF-mass spectrometry
    Weidner, SM
    Just, U
    Wittke, W
    Rittig, F
    Gruber, F
    Friedrich, JF
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2004, 238 (03) : 235 - 244
  • [13] MICRO COLUMN LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY USING A CAPILLARY INTERFACE
    HIRTER, P
    WALTHER, HJ
    DATWYLER, P
    JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01): : 89 - 98
  • [14] Analysis of carbohydrate heterogeneity in a glycoprotein using liquid chromatography mass spectrometry and liquid chromatography with tandem mass spectrometry
    Kawasaki, N
    Ohta, M
    Hyuga, S
    Hashimoto, O
    Hayakawa, T
    ANALYTICAL BIOCHEMISTRY, 1999, 269 (02) : 297 - 303
  • [15] New liquid chromatography, mass spectrometry, and liquid chromatography/mass spectrometry instruments
    Sherma, Joseph
    Larkin, John D.
    Larkin, Frances H.
    JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (01) : 15A - 21A
  • [16] MONODISPERSE AEROSOL GENERATION INTERFACE FOR COMBINING LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY (MAGIC) - GENERAL APPLICATIONS
    WILLOUGHBY, RC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1985, 189 (APR-): : 67 - ANYL
  • [17] Evaluation of a liquid electron ionization liquid chromatography-mass spectrometry interface
    Termopoli, Veronica
    Famiglini, Giorgio
    Palma, Pierangela
    Piergiovanni, Maurizio
    Rocio-Bautista, Priscilla
    Ottaviani, Maria Francesca
    Cappiello, Achille
    Saeed, Mansoor
    Perry, Simon
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1591 : 120 - 130
  • [19] Mass spectrometry - Combining techniques with chromatography
    Jahn, K
    Jahn, K
    NACHRICHTEN AUS CHEMIE TECHNIK UND LABORATORIUM, 1997, 45 : S29 - +
  • [20] Profiling degradants of paclitaxel using liquid chromatography mass spectrometry and liquid chromatography tandem mass spectrometry substructural techniques
    Volk, KJ
    Hill, SE
    Kerns, EH
    Lee, MS
    JOURNAL OF CHROMATOGRAPHY B, 1997, 696 (01): : 99 - 115