Combining liquid chromatography with MALDI mass spectrometry using a heated droplet interface

被引:48
|
作者
Zhang, BY [1 ]
McDonald, C [1 ]
Li, L [1 ]
机构
[1] Univ Alberta, Dept Chem, Edmonton, AB T6G 2G2, Canada
关键词
D O I
10.1021/ac034934s
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel interfacing technology is described to combine solution-based separation techniques such as liquid chromatography (LC) with matrix-assisted laser desorption ionization (MALDI) mass spectrometry. The interface includes a transfer tube having an inlet and an outlet, the inlet being adapted to accept the LC effluents and the outlet being adapted to form continuously replaced, hanging droplets of the liquid stream, and a MALDI sample plate mounted below the outlet of the transfer tube for collecting the droplets. The liquid stream in the transfer tube is heated to a temperature sufficient to cause partial evaporation of the carrier solvent from the hanging droplets. The droplets are dislodged to the MALDI plate, which is heated to above the boiling point of the carrier solvent to cause further evaporation of the carrier solvent from the collected droplets. It is found that analytes can be fractionated and deposited to a sample spot of 0.8 mm in diameter when a liquid flow rate of up to 50 muL/min and a fractionation interval of 1 min/spot are used. Flow rate of up to 200 muL/min can be used with a deposition sample spot of 2.4 mm in diameter on a commercial MALDI target. This heated droplet interface does not introduce sample loss, and the detection sensitivity of LC/MALDI is similar to that of standard MALDI, i.e., low femtomoles for peptide analysis with a microliter sample deposition. It is compatible with microbore and narrowbore column separation, thus allowing the injection of a larger amount of sample for separation and analysis, compared to a capillary column LC/MALDI system. The detection dynamic range is shown to be in the order of 106 for peptide mixture analysis, which is 4 orders of magnitude greater than standard MALDI. The application of this interface for combining LC with MALDI MS/MS is demonstrated in the proteome analysis of water-soluable protein components of E. coli K12 extracts.
引用
收藏
页码:992 / 1001
页数:10
相关论文
共 50 条
  • [1] Polymer characterization by combining liquid chromatography with MALDI and ESI mass spectrometry
    Renata Murgasova
    David M. Hercules
    Analytical and Bioanalytical Chemistry, 2002, 373 : 481 - 489
  • [2] Polymer characterization by combining liquid chromatography with MALDI and ESI mass spectrometry
    Murgasova, R
    Hercules, DM
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 373 (06) : 481 - 489
  • [3] Atmospheric Pressure Free Liquid Infrared MALDI Mass Spectrometry: Toward a combined ESI/MALDI-Liquid Chromatography Interface
    Rapp, Erdmann
    Charvat, Ales
    Beinsen, Alexander
    Plessmann, Uwe
    Reichl, Udo
    Seidel-Morgenstern, Andreas
    Urlaub, Henning
    Abel, Bernd
    ANALYTICAL CHEMISTRY, 2009, 81 (01) : 443 - 452
  • [4] MONODIPERSE AEROSOL GENERATION INTERFACE FOR COMBINING LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY (MAGIC) - OPTIMIZATION
    WILLOUGHBY, RC
    BROWNER, RF
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 188 (AUG): : 84 - ANYL
  • [5] Integrated liquid chromatography-heated nebulizer microchip for mass spectrometry
    Haapala, Markus
    Saarela, Ville
    Pol, Jaroslav
    Kolari, Kai
    Kotiaho, Tapio
    Franssila, Sami
    Kostiainen, Risto
    ANALYTICA CHIMICA ACTA, 2010, 662 (02) : 163 - 169
  • [6] DIRECT ELECTRICALLY HEATED SPRAY DEVICE FOR A MOVING BELT LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY INTERFACE
    KRESBACH, GM
    BAKER, TR
    NELSON, RJ
    WRONKA, J
    KARGER, BL
    VOUROS, P
    JOURNAL OF CHROMATOGRAPHY, 1987, 394 (01): : 89 - 100
  • [7] A Nano LC-MALDI Mass Spectrometry Droplet Interface for the Analysis of Complex Protein Samples
    Pereira, Fiona
    Niu, Xize
    deMello, Andrew J.
    PLOS ONE, 2013, 8 (05):
  • [8] A discharge adaptor interface for use in liquid chromatography/mass spectrometry
    Sheen, Jenn-Feng
    Ho, Ya-Hui
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (24) : 3675 - 3682
  • [9] ELECTROSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    HIRAOKA, K
    KUDAKA, I
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (12) : 519 - 526
  • [10] A new liquid chromatography mass spectrometry interface: Laser spray
    Hiraoka, K
    Saito, S
    Katsuragawa, J
    Kudaka, I
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1998, 12 (17) : 1170 - 1174