Development of a continuous radon concentration monitoring system in underground soil

被引:9
|
作者
Yamamoto, S [1 ]
Tarutani, K
Yamasoto, K
Iskandar, D
Iida, T
机构
[1] Kobe City Coll Technol, Kobe, Hyogo, Japan
[2] Nagoya Univ, Nagoya, Aichi, Japan
关键词
continuous measurement; radon; real time; underground soil;
D O I
10.1109/23.940086
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A continuous radon (Rn-222) concentration monitoring system for use in underground soil was developed and tested. The system consists of a 19-mm-diameter, 1100-mm-long detector assembly and a microprocessor based data logger. A small volume chamber is installed at the tip of the detector assembly. A thin ZnS(Ag) scintillator film inside the chamber and a photomultiplier tube (PMT) detect alpha particles from radon and its daughters. When the system is in measurement, the detector part is buried into underground soil. An energy resolution of approximately 70 % full width half maximum (FWHM) was obtained for 5.5 MeV alpha particles from Am-241. Both the rise time and fall time for the system were measured to be approximately 1-2 h. Temporal variations in underground radon concentration at different depths were investigated simultaneously using four sets of the developed system. The results confirmed that the developed system is useful for continuous measurement of radon concentration in underground soil.
引用
收藏
页码:391 / 394
页数:4
相关论文
共 50 条
  • [31] Influence of ventilation on the reduction of the radon concentration in an underground research facility
    Liu, C. L.
    Zhao, Y. J.
    Li, S. S.
    Teng, H. J.
    Wang, Z. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2007, 274 (03) : 507 - 510
  • [32] Influence of ventilation on the reduction of the radon concentration in an underground research facility
    C. L. Liu
    Y. J. Zhao
    S. S. Li
    H. J. Teng
    Z. M. Wang
    Journal of Radioanalytical and Nuclear Chemistry, 2007, 274 : 507 - 510
  • [33] Remote real-time control of aerosol continuous monitoring for high radon concentration environments
    Wang, Ge
    Huang, Zihan
    Xu, Hongkun
    Yin, Yin
    Mu, Changli
    Wang, Qiong
    APPLIED RADIATION AND ISOTOPES, 2020, 155 (155)
  • [34] A Cost-Effective IoT System for Monitoring Indoor Radon Gas Concentration
    Blanco-Novoa, Oscar
    Fernandez-Carames, Tiago M.
    Fraga-Lamas, Paula
    Castedo, Luis
    SENSORS, 2018, 18 (07)
  • [35] A continuous radon monitoring system based on a solid-state silicon detector
    Pena-Eguiluz, R.
    Garcia-Hernandez, J. M.
    Ramirez-Jimenez, F. J.
    JOURNAL OF APPLIED RESEARCH AND TECHNOLOGY, 2007, 5 (01) : 3 - 9
  • [36] Groundwater, Radon Continuous Monitoring System (α-scintillation Counting) for Natural Hazard Surveillance
    G. Galli
    C. Mancini
    F. Quattrocchi
    pure and applied geophysics, 2000, 157 : 407 - 433
  • [37] Groundwater, radon continuous monitoring system (α-scintillation counting) for natural hazard surveillance
    Galli, G
    Mancini, C
    Quattrocchi, F
    PURE AND APPLIED GEOPHYSICS, 2000, 157 (03) : 407 - 433
  • [38] Continuous underground monitoring of gas leaks
    Khalil, GE
    Kimura, F
    Chin, A
    Ghandehari, M
    Wan, R
    Shinoki, W
    Gouterman, M
    Callis, JB
    Dalton, LR
    RESEARCH IN NONDESTRUCTIVE EVALUATION, 2005, 16 (03) : 119 - 130
  • [39] RADON-IN-SOIL CONCENTRATION LEVELS IN MEXICO
    SEGOVIA, N
    TAMEZ, E
    MENA, M
    RADIATION PROTECTION DOSIMETRY, 1992, 45 (1-4) : 241 - 244
  • [40] Role of environmental variables on radon concentration in soil
    Climent, H
    Bakalowicz, M
    Monnin, M
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 324 - 329