Use of the Arndt wire-guided endobronchial blocker via nasal for one-tung ventilation in patient with anticipated restricted mouth opening for esophagectomy

被引:13
作者
Ho, CYA [1 ]
Chen, CY [1 ]
Yang, MW [1 ]
Liu, HP [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Anesthesia, Taoyuan 333, Taiwan
关键词
wire-guided endobronchial blockade; restricted mouth opening; one-tung ventilation;
D O I
10.1016/j.ejcts.2005.03.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new toot for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gastric tube substitution. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 175
页数:2
相关论文
共 10 条
[1]   ANESTHETIC IMPLICATIONS OF TEMPOROMANDIBULAR-JOINT DISEASE [J].
AIELLO, G ;
METCALF, I .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (06) :610-616
[2]   Single-lung ventilation in a critically ill patient using a fiberoptically directed wire-guided endobronchial blocker [J].
Arndt, GA ;
Kranner, PW ;
Rusy, DA ;
Love, R .
ANESTHESIOLOGY, 1999, 90 (05) :1484-1486
[3]   One-lung ventilation when intubation is difficult - presentation of a new endobronchial blocker [J].
Arndt, GA ;
DeLessio, S ;
Kranner, PW ;
Orzepowski, W ;
Ceranski, B ;
Valtysson, B .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (03) :356-358
[4]   MARGIN OF SAFETY IN POSITIONING MODERN DOUBLE-LUMEN ENDOTRACHEAL-TUBES [J].
BENUMOF, JL ;
PARTRIDGE, BL ;
SALVATIERRA, C ;
KEATING, J .
ANESTHESIOLOGY, 1987, 67 (05) :729-738
[5]  
BENUMOF JL, 1991, ANESTHESIOLOGY, V75, P1087
[6]  
BENUMOF JL, 1996, AIRWAY MANAGEMENT PR, P412
[7]  
GINSBERG RJ, 1981, J THORAC CARDIOV SUR, V82, P542
[8]   Nasal intubation and one-lung ventilation [J].
Gozal, Y ;
Lee, W .
ANESTHESIOLOGY, 1996, 84 (02) :477-477
[9]  
LARSON CE, 1990, ANESTH ANALG, V71, P311
[10]   EVALUATION OF A NEW TRACHEAL TUBE WITH A MOVABLE BRONCHUS BLOCKER [J].
MACGILLIVRAY, RG .
ANAESTHESIA, 1988, 43 (08) :687-689