Use of the Arndt wire-guided endobronchial blocker via nasal for one-tung ventilation in patient with anticipated restricted mouth opening for esophagectomy

被引:13
作者
Ho, CYA [1 ]
Chen, CY [1 ]
Yang, MW [1 ]
Liu, HP [1 ]
机构
[1] Chang Gung Mem Hosp, Dept Anesthesia, Taoyuan 333, Taiwan
关键词
wire-guided endobronchial blockade; restricted mouth opening; one-tung ventilation;
D O I
10.1016/j.ejcts.2005.03.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Functional separation of the lungs may be accomplished by several methods. Patient with restricted mouth opening has limited options for one-lung ventilation. We report the use of wire-guided endobronchial blockade, a new toot for achieving one-lung ventilation in a patient with restricted mouth opening requiring nasotracheal, fiberoptic intubation for esophagectomy and reconstruction with gastric tube substitution. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:174 / 175
页数:2
相关论文
共 10 条
  • [1] ANESTHETIC IMPLICATIONS OF TEMPOROMANDIBULAR-JOINT DISEASE
    AIELLO, G
    METCALF, I
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1992, 39 (06): : 610 - 616
  • [2] Single-lung ventilation in a critically ill patient using a fiberoptically directed wire-guided endobronchial blocker
    Arndt, GA
    Kranner, PW
    Rusy, DA
    Love, R
    [J]. ANESTHESIOLOGY, 1999, 90 (05) : 1484 - 1486
  • [3] One-lung ventilation when intubation is difficult - presentation of a new endobronchial blocker
    Arndt, GA
    DeLessio, S
    Kranner, PW
    Orzepowski, W
    Ceranski, B
    Valtysson, B
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1999, 43 (03) : 356 - 358
  • [4] MARGIN OF SAFETY IN POSITIONING MODERN DOUBLE-LUMEN ENDOTRACHEAL-TUBES
    BENUMOF, JL
    PARTRIDGE, BL
    SALVATIERRA, C
    KEATING, J
    [J]. ANESTHESIOLOGY, 1987, 67 (05) : 729 - 738
  • [5] BENUMOF JL, 1991, ANESTHESIOLOGY, V75, P1087
  • [6] BENUMOF JL, 1996, AIRWAY MANAGEMENT PR, P412
  • [7] GINSBERG RJ, 1981, J THORAC CARDIOV SUR, V82, P542
  • [8] Nasal intubation and one-lung ventilation
    Gozal, Y
    Lee, W
    [J]. ANESTHESIOLOGY, 1996, 84 (02) : 477 - 477
  • [9] LARSON CE, 1990, ANESTH ANALG, V71, P311
  • [10] EVALUATION OF A NEW TRACHEAL TUBE WITH A MOVABLE BRONCHUS BLOCKER
    MACGILLIVRAY, RG
    [J]. ANAESTHESIA, 1988, 43 (08) : 687 - 689