A review of the image segmentation and registration methods in liver motion correction in C-arm perfusion imaging

被引:0
|
作者
Haseljic, Hana [1 ]
Frysch, Robert [1 ]
Kulvait, Vojtech [1 ]
Rose, Georg [1 ]
机构
[1] Otto von Guericke Univ, Inst Med Engn & Res Campus STIMUIATE, Univ Pl 2, D-39106 Magdeburg, Germany
来源
2019 XXVII INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATION AND AUTOMATION TECHNOLOGIES (ICAT 2019) | 2019年
关键词
C-arm; perfusion imaging; motion correction; image registration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The C-arm perfusion imaging is not yet the standard part for liver cancer diagnosis and intraoperative measurements. The number of multiple rotations of C-arm depends on the total angle range resulting in large number of projections. Usually most of the liver disease features can be visible on CT images. However, the breathing and other liver surrounding organs motion during the acquisition can cause artifacts or missing important data on reconstructed CT images. In C-arm systems this is the consequence of the slow rotation. This paper gives an overview of existing motion correction algorithms used in medical imaging. These algorithms are based on image segmentation and registration.
引用
收藏
页数:6
相关论文
共 25 条
  • [1] Clinical Applications of Quantitative Perfusion Imaging with a C-Arm Flat-Panel Detector-A Systematic Review
    Al-Kaylani, Abdallah H. A. Zaid
    Schuurmann, Richte C. L.
    Maathuis, Wouter D.
    Slart, Riemer H. J. A.
    De Vries, Jean-Paul P. M.
    Bokkers, Reinoud P. H.
    DIAGNOSTICS, 2023, 13 (01)
  • [2] Fast C-arm projection image correction based on visual model
    Lv S.
    Meng C.
    Zhou F.
    Liu B.
    Zhou X.
    Gaojishu Tongxin/Chinese High Technology Letters, 2010, 20 (01): : 94 - 98
  • [3] In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL PHYSICS, 2012, 39 (11) : 6652 - 6659
  • [4] Visual Model Based C-arm System Calibration and Image Correction
    Lv, Shaojie
    Meng, Cai
    Zhou, Fugen
    Liu, Bo
    Zhou, Xiaojun
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 454 - +
  • [5] C-Arm Perfusion Imaging with a Fast Penalized Maximum-Likelihood Approach
    Frysch, Robert
    Pfeiffer, Tim
    Bannasch, Sebastian
    Serowy, Steffen
    Gugel, Sebastian
    Skalej, Martin
    Rose, Georg
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [6] Evaluating the Feasibility of C-arm CT for Brain Perfusion Imaging: An in vitro Study
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [7] SPATIO-TEMPORAL IMAGE REGISTRATION FOR RESPIRATORY MOTION CORRECTION IN PET IMAGING
    Bai, Wenjia
    Brady, Michael
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 426 - 429
  • [8] Simultaneous 3D-2D image registration and C-arm calibration: Application to endovascular image-guided interventions
    Mitrovic, Uros
    Pernus, Franjo
    Likar, Bostjan
    Spiclin, Ziga
    MEDICAL PHYSICS, 2015, 42 (11) : 6433 - 6447
  • [9] Dynamic Iterative Reconstruction for Interventional 4-D C-Arm CT Perfusion Imaging
    Manhart, Michael T.
    Kowarschik, Markus
    Fieselmann, Andreas
    Deuerling-Zheng, Yu
    Royalty, Kevin
    Maier, Andreas K.
    Hornegger, Joachim
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (07) : 1336 - 1348
  • [10] Evaluation of a Motion Correction Algorithm for C-Arm Computed Tomography Acquired During Transarterial Chemoembolization
    Becker, Lena S.
    Gutberlet, Marcel
    Maschke, Sabine K.
    Werncke, Thomas
    Dewald, Cornelia L. A.
    von Falck, Christian
    Vogel, Arndt
    Kloeckner, Roman
    Meyer, Bernhard C.
    Wacker, Frank
    Hinrichs, Jan B.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (04) : 610 - 618