Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement

被引:87
|
作者
Bloch, O
Holly, LT
Park, J
Obasi, C
Kim, K
Johnson, JP
机构
[1] Cedars Sinai Inst Spinal Disorders, Los Angeles, CA 90048 USA
[2] Univ Calif Los Angeles, Med Ctr, Los Angeles, CA 90024 USA
[3] Univ Washington, Seattle, WA 98195 USA
[4] Arrowhead Reg Med Ctr, San Bernardino, CA USA
[5] Univ Calif Davis, Med Ctr, Sacramento, CA 95817 USA
关键词
screw fixation; frameless stereotaxy; cervical spine;
D O I
10.3171/spi.2001.95.1.0074
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. In recent studies some authors have indicated that 20% of patients have at least one ectatic vertebral artery (VA) that, based on previous criteria in which preoperative computerized tomography (CT) and standard intraoperative fluoroscopic techniques were used, may prevent the safe placement of C1-2 transarticular screws. The authors conducted this study to determine whether frameless stereotaxy would improve the accuracy of C1-2 transarticular screw placement in healthy patients, particularly those whom previous criteria would have excluded. Methods. The authors assessed the accuracy of frameless stereotaxy for C1-2 transarticular screw placement in 17 cadaveric cervical spines. Preoperatively obtained CT scans of the C-2 vertebra were registered on a stereotactic workstation. The dimensions of the C-2 pars articularis were measured on the workstation, and a 3.5-mm screw was stereotactically placed if the height and width of the pars interarticularis was greater than 4 mm. The specimens were evaluated with postoperative CT scanning and visual inspection. Screw placement was considered acceptable if the screw was contained within the C-2 pars interarticularis, traversed the C1-2 joint, and the screw tip was shown to be within the anterior cortex of the C-l lateral mass. Transarticular screws were accurately placed in 16 cadaveric specimens, and only one specimen (5.9%) was excluded because of anomalous VA anatomy. In contrast, a total of four specimens (23.5%) showed significant narrowing of the C-2 pars interarticularis due to vascular anatomy that would have precluded atlantoaxial transarticular screw placement had previous nonimage-guided criteria been used. Conclusions. Frameless stereotaxy provides precise image guidance that improves the safety of C1-2 transarticular screw placement and potentially allows this procedure to be performed in patients previously excluded because of the inaccuracy of nonimage-guided techniques.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 50 条
  • [1] C2 laminar screw and C1-2 transarticular screw combined with C1 laminar hooks for atlantoaxial instability with unilateral vertebral artery injury
    Guo, Qunfeng
    Liu, Jun
    Ni, Bin
    Lu, Xuhua
    Zhou, Fengjin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (09) : 1207 - 1210
  • [2] An anatomical study comparing standard fluoroscopy and virtual fluoroscopy for the placement of C1-2 transarticular screws
    Tannoury, T
    Crowl, AC
    Battaglia, TC
    Chan, DPK
    Anderson, DG
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (05) : 584 - 588
  • [3] Frameless stereotactic image-guided C1-C2 transarticular screw fixation for atlantoaxial instability - Review of 20 patients
    Acosta, FL
    Quinones-Hinojosa, A
    Gadkary, CA
    Schmidt, MH
    Chin, CT
    Ames, CP
    Rosenberg, WS
    Weinstein, P
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (05): : 385 - 391
  • [4] Combination of skull traction with posterior C1-2 fusion for old C1-2 dislocations
    Li, Xue Feng
    Yang, Hui Lin
    Jiang, Wei Min
    Tang, Tian Si
    Gong, Xiao Hong
    Yuan, Jing
    Zhang, Ji Gang
    Wang, Gen Lin
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (06) : 768 - 773
  • [5] Deviation Analysis of C1-C2 Transarticular Screw Placement Assisted by a Novel Rapid Prototyping Drill Template A Cadaveric Study
    Hu, Yong
    Yuan, Zhen-Shan
    Kepler, Christopher K.
    Albert, Todd J.
    Yuan, Jian-Bing
    Dong, Wei-Xin
    Sun, Xiao-Yang
    Wang, Cheng-Tao
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2014, 27 (05): : E181 - E186
  • [6] Posterior C1-2 fusion with C1 lateral mass and C2 isthmic screws: accuracy of screw position, alignment and patient outcome
    Ringel, Florian
    Reinke, Andreas
    Stueer, Carsten
    Meyer, Bernhard
    Stoffel, Michael
    ACTA NEUROCHIRURGICA, 2012, 154 (02) : 305 - 312
  • [7] Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation
    Jun, BY
    SPINE, 1998, 23 (15) : 1703 - 1707
  • [8] Transarticular atlanto-axial screw fixation for treatment of C1-C2 instability
    Toussaint, P
    Desenclos, C
    Peltier, J
    Le Gars, D
    NEUROCHIRURGIE, 2003, 49 (05) : 519 - 526
  • [9] Posterior C1-C2 transarticular screw fixation for instability of the C0-C2 complex
    Martín-Ferrer, S
    Rimbau, J
    Joly, MC
    Teruel, J
    Pont, J
    NEUROCIRUGIA, 2000, 11 (01): : 43 - 49
  • [10] Anthropometric evaluation for surgical feasibility of C1-C2 transarticular screw stabilization in Indian population
    Raut, Saijyot
    Kundnani, Vishal G.
    Meena, Mohit Kumar
    Patel, Jwalant Y.
    Asati, Sanjeev
    Patel, Ankit
    JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2021, 12 (02) : 129 - 135