Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments

被引:58
|
作者
Mize, SB [1 ]
Clement, DJ [1 ]
Pruett, JP [1 ]
Carnes, DL [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Endodont, San Antonio, TX 78284 USA
关键词
D O I
10.1016/S0099-2399(98)80015-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The ability of heat treatment as a result of autoclave sterilization to extend the life of nickel-titanium rotary endodontic instruments by reducing the effect of cyclic fatigue was evaluated using 280 size 40 Lightspeed instruments. Instruments were cycled in artificial canals with angles of curvature of 30 degrees and either 2 or 5 mm radii of curvature. In a pilot study, instruments were sterilized or not sterilized and cycled to failure to obtain mean cycles-to-failure values for each group. In the first experimental protocol, instruments were cycled to either 25%, 50%, or 75% of the mean cycles-to-failure limit determined in the pilot study, then sterilized or not sterilized before being cycled to failure. In the second experimental protocol, instruments were cycled to 25% of the mean cycles-to-failure determined in the pilot study, and sterilized or not sterilized. This sequence of cycling to 25% of the predetermined cycles-to-failure limit followed by sterilization was repeated until the instruments failed. No significant increases in cycles to failure were observed between groups for either experimental protocol when instruments were evaluated at a similar radius. Significant differences in cycles to failure were only observed when instruments cycled to failure in the artificial canal with 2 mm radius were compared with instruments cycled to failure in the artificial canal of 5 mm radius. Scanning electron microscopic photos showed crack initiation and propagation in all instruments that were cycled to a percentage of the predetermined cycles-to-failure limit. It is concluded that heat treatment as a result of autoclave sterilization does not extend the useful life of nickel-titanium instruments.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 50 条
  • [21] Cyclic Fatigue of Different Nickel-Titanium Rotary Instruments: A Comparative Study
    Testarelli, L.
    Grande, N. M.
    Plotino, G.
    Lendini, M.
    Pongione, G.
    De Paolis, G.
    Rizzo, F.
    Milana, V.
    Gambarini, G.
    OPEN DENTISTRY JOURNAL, 2009, 3 : 55 - 58
  • [22] A comparison of cyclic fatigue resistance in reciprocating and rotary nickel-titanium instruments
    Wan, Jeffrey
    Rasimick, Brian J.
    Musikant, Barry L.
    Deutsch, Allan S.
    AUSTRALIAN ENDODONTIC JOURNAL, 2011, 37 (03) : 122 - 127
  • [23] Cyclic Fatigue Testing and Metallographic Analysis of Nickel-Titanium Rotary Instruments
    Pirani, Chiara
    Cirulli, Pier Paolo
    Chersoni, Stefano
    Micele, Lorenzo
    Ruggeri, Oddone
    Prati, Carlo
    JOURNAL OF ENDODONTICS, 2011, 37 (07) : 1013 - 1016
  • [24] Comparison of cyclic fatigue resistance of novel nickel-titanium rotary instruments
    Capar, Ismail Davut
    Ertas, Huseyin
    Arslan, Hakan
    AUSTRALIAN ENDODONTIC JOURNAL, 2015, 41 (01) : 24 - 28
  • [25] Effect of cyclic fatigue on static fracture loads in ProTaper nickel-titanium rotary instruments
    Ullmann, CJ
    Peters, OA
    JOURNAL OF ENDODONTICS, 2005, 31 (03) : 183 - 186
  • [26] Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments
    Ounsi, Hani F.
    Salameh, Ziad
    Al-Shalan, Thakib
    Ferrari, Marco
    Grandini, Simone
    Pashley, David H.
    Tay, Franklin R.
    JOURNAL OF ENDODONTICS, 2007, 33 (06) : 737 - 741
  • [27] Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files
    Silvaggio, J
    Hicks, ML
    JOURNAL OF ENDODONTICS, 1997, 23 (12) : 731 - 734
  • [28] Influence of Different Angles of Reciprocation on the Cyclic Fatigue of Nickel-Titanium Endodontic Instruments
    Gambarini, Gianluca
    Rubini, Alessio Giansiracusa
    Al Sudani, Dina
    Gergi, Richard
    Culla, Antonio
    De Angelis, Francesca
    Di Carlo, Stefano
    Pompa, Giorgio
    Osta, Nada
    Testarelli, Luca
    JOURNAL OF ENDODONTICS, 2012, 38 (10) : 1408 - 1411
  • [29] Survival Analysis of Factors Influencing Cyclic Fatigue of Nickel-Titanium Endodontic Instruments
    Fiserova, Eva
    Chvostekova, Martina
    Bjlaskova, Silvie
    Bumbalek, Michal
    Joska, Zdenek
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2015, 2015
  • [30] Torsion property and cyclic fatigue fracture behavior of nickel-titanium endodontic instruments
    Zheng, YF
    Li, C
    Huang, C
    Zhao, LC
    ASBM6: ADVANCED BIOMATERIALS VI, 2005, 288-289 : 603 - 606