Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments

被引:58
|
作者
Mize, SB [1 ]
Clement, DJ [1 ]
Pruett, JP [1 ]
Carnes, DL [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Endodont, San Antonio, TX 78284 USA
关键词
D O I
10.1016/S0099-2399(98)80015-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The ability of heat treatment as a result of autoclave sterilization to extend the life of nickel-titanium rotary endodontic instruments by reducing the effect of cyclic fatigue was evaluated using 280 size 40 Lightspeed instruments. Instruments were cycled in artificial canals with angles of curvature of 30 degrees and either 2 or 5 mm radii of curvature. In a pilot study, instruments were sterilized or not sterilized and cycled to failure to obtain mean cycles-to-failure values for each group. In the first experimental protocol, instruments were cycled to either 25%, 50%, or 75% of the mean cycles-to-failure limit determined in the pilot study, then sterilized or not sterilized before being cycled to failure. In the second experimental protocol, instruments were cycled to 25% of the mean cycles-to-failure determined in the pilot study, and sterilized or not sterilized. This sequence of cycling to 25% of the predetermined cycles-to-failure limit followed by sterilization was repeated until the instruments failed. No significant increases in cycles to failure were observed between groups for either experimental protocol when instruments were evaluated at a similar radius. Significant differences in cycles to failure were only observed when instruments cycled to failure in the artificial canal with 2 mm radius were compared with instruments cycled to failure in the artificial canal of 5 mm radius. Scanning electron microscopic photos showed crack initiation and propagation in all instruments that were cycled to a percentage of the predetermined cycles-to-failure limit. It is concluded that heat treatment as a result of autoclave sterilization does not extend the useful life of nickel-titanium instruments.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 50 条
  • [1] The Effect of Temperature on Cyclic Fatigue of Nickel-titanium Rotary Endodontic Instruments
    Dosanjh, Amandeep
    Paurazas, Susan
    Askar, Mazin
    JOURNAL OF ENDODONTICS, 2017, 43 (05) : 823 - 826
  • [2] Cyclic fatigue of different nickel-titanium endodontic rotary instruments
    Tripi, Teresa Roberta
    Bonaccorso, Antonio
    Condorelli, Guglielmo Guido
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (04): : E106 - E114
  • [3] In vitro cyclic fatigue analysis of different endodontic Nickel-Titanium rotary instruments
    Cutro, Giuseppe
    Amateis, Valentina
    Provenzano, Salvatore C.
    Cusimano, Paolo
    Cumbo, Enzo M.
    Gallina, Giuseppe
    GIORNALE ITALIANO DI ENDODONZIA, 2012, 26 (03): : 145 - 149
  • [4] An In Vitro Cyclic Fatigue Analysis of Different Endodontic Nickel-Titanium Rotary Instruments
    Bhagabati, Nilav
    Yadav, Seema
    Talwar, Sangeeta
    JOURNAL OF ENDODONTICS, 2012, 38 (04) : 515 - 518
  • [5] Influence of Rotational Speed on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Lopes, Helio P.
    Ferreira, Alessandra A. P.
    Elias, Carlos N.
    Moreira, Edson J. L.
    Machado de Oliveira, Julio C.
    Siqueira, Jose F., Jr.
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1013 - 1016
  • [6] Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments
    Viana, A. C. D.
    Gonzalez, B. M.
    Buono, V. T. L.
    Bahia, M. G. A.
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (09) : 709 - 715
  • [7] Cyclic fatigue testing of nickel-titanium endodontic instruments
    Pruett, JP
    Clement, DJ
    Carnes, DL
    JOURNAL OF ENDODONTICS, 1997, 23 (02) : 77 - 85
  • [8] Dynamic and cyclic fatigue of engine-driven rotary nickel-titanium endodontic instruments
    Haïkel, Y
    Serfaty, R
    Bateman, G
    Senger, B
    Allemann, C
    JOURNAL OF ENDODONTICS, 1999, 25 (06) : 434 - 440
  • [9] Influence of Different Manufacturing Methods on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Rodrigues, Renata C. V.
    Lopes, Helio P.
    Elias, Carlos N.
    Amaral, Georgiana
    Vieira, Victor T. L.
    De Martin, Alexandre S.
    JOURNAL OF ENDODONTICS, 2011, 37 (11) : 1553 - 1557
  • [10] Predicting in vivo failure of rotary nickel-titanium endodontic instruments under cyclic fatigue
    Stojanac, Igor
    Drobac, Milan
    Petrovic, Ljubomir
    Atanackovic, Teodor
    DENTAL MATERIALS JOURNAL, 2012, 31 (04) : 650 - 655