Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments

被引:58
作者
Mize, SB [1 ]
Clement, DJ [1 ]
Pruett, JP [1 ]
Carnes, DL [1 ]
机构
[1] Univ Texas, Hlth Sci Ctr, Sch Dent, Dept Endodont, San Antonio, TX 78284 USA
关键词
D O I
10.1016/S0099-2399(98)80015-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The ability of heat treatment as a result of autoclave sterilization to extend the life of nickel-titanium rotary endodontic instruments by reducing the effect of cyclic fatigue was evaluated using 280 size 40 Lightspeed instruments. Instruments were cycled in artificial canals with angles of curvature of 30 degrees and either 2 or 5 mm radii of curvature. In a pilot study, instruments were sterilized or not sterilized and cycled to failure to obtain mean cycles-to-failure values for each group. In the first experimental protocol, instruments were cycled to either 25%, 50%, or 75% of the mean cycles-to-failure limit determined in the pilot study, then sterilized or not sterilized before being cycled to failure. In the second experimental protocol, instruments were cycled to 25% of the mean cycles-to-failure determined in the pilot study, and sterilized or not sterilized. This sequence of cycling to 25% of the predetermined cycles-to-failure limit followed by sterilization was repeated until the instruments failed. No significant increases in cycles to failure were observed between groups for either experimental protocol when instruments were evaluated at a similar radius. Significant differences in cycles to failure were only observed when instruments cycled to failure in the artificial canal with 2 mm radius were compared with instruments cycled to failure in the artificial canal of 5 mm radius. Scanning electron microscopic photos showed crack initiation and propagation in all instruments that were cycled to a percentage of the predetermined cycles-to-failure limit. It is concluded that heat treatment as a result of autoclave sterilization does not extend the useful life of nickel-titanium instruments.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 8 条
  • [1] THE ANTI-CURVATURE FILING METHOD TO PREPARE THE CURVED ROOT-CANAL
    ABOURASS, M
    FRANK, AL
    GLICK, DH
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1980, 101 (05) : 792 - 794
  • [2] Council on Dental Materials and Devices, 1976, J AM DENT ASSOC, V93, P813, DOI 10.14219/jada.archive.1976.0087
  • [3] A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS
    GLOSSON, CR
    HALLER, RH
    DOVE, SB
    DELRIO, CE
    [J]. JOURNAL OF ENDODONTICS, 1995, 21 (03) : 146 - 151
  • [4] Cyclic fatigue testing of nickel-titanium endodontic instruments
    Pruett, JP
    Clement, DJ
    Carnes, DL
    [J]. JOURNAL OF ENDODONTICS, 1997, 23 (02) : 77 - 85
  • [5] THE BALANCED FORCE CONCEPT FOR INSTRUMENTATION OF CURVED CANALS
    ROANE, JB
    SABALA, CL
    DUNCANSON, MG
    [J]. JOURNAL OF ENDODONTICS, 1985, 11 (05) : 203 - 211
  • [6] SERENE TP, 1995, NICKEL TITANIUM INST, pCH5
  • [7] STRESS-STRAIN-TEMPERATURE RELATIONSHIPS OF TINI SHAPE MEMORY ALLOY SUITABLE FOR THERMOMECHANICAL CYCLING
    TOBUSHI, H
    IWANAGA, H
    TANAKA, K
    HORI, T
    SAWADA, T
    [J]. JSME INTERNATIONAL JOURNAL SERIES I-SOLID MECHANICS STRENGTH OF MATERIALS, 1992, 35 (03): : 271 - 277
  • [8] WEINE F, 1989, ENDODONTIC THERAPY, pCH6