Biocatalytic gas-liquid membrane contactors for CO2 hydration with immobilized carbonic anhydrase

被引:52
|
作者
Hou, Jingwei [1 ]
Zulkifli, Muhammad Yazid [1 ]
Mohammad, Munirah [1 ]
Zhang, Yatao [1 ,2 ]
Razmjou, Amir [1 ,3 ]
Chen, Vicki [1 ]
机构
[1] Univ New South Wales, Sch Chem Engn, UNESCO Ctr Membrane Sci & Technol, Sydney, NSW 2052, Australia
[2] Zhengzhou Univ, Sch Chem Engn & Energy, Zhengzhou 450001, Peoples R China
[3] Univ Isfahan, Fac Adv Sci & Technol, Dept Biotechnol, Esfahan, Iran
基金
澳大利亚研究理事会;
关键词
Gas-liquid membrane contactor; Carbonic anhydrase; TiO2; nanoparticles; Enzyme immobilization; CO2; capture; HOLLOW-FIBER MEMBRANE; MASS-TRANSFER; ABSORPTION; CAPTURE; SEPARATION; SURFACE; DEGRADATION; RESISTANCE;
D O I
10.1016/j.memsci.2016.07.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
CO2 capture from flue gas, biogas and natural gas is still a key challenge in many environmental and energy applications. The gas-liquid membrane contactor provides a promising alternative to traditional packed towers and bubble columns. We developed a novel biocatalytic gas-liquid membrane contactor for CO2 capture with benign solvent absorbents. Both virgin and superhydrophobic PP hollow fiber membranes were investigated. Biocatalytic TiO2 nanoparticles with covalently immobilized carbonic anhydrase were suspended in the solvent absorbent to promote the CO2 hydration. The immobilized enzyme retained a high degree of the original CO2 hydration efficiency of the free enzyme, and the biocatalytic membrane contactor performance under various industrial-related conditions was investigated, including a wide range of pH and high temperature. Satisfactory reusability of the biocatalytic nanoparticles was exhibited by 10 cycles of repeated use. Finally, the mass transfer study and the Wilson plot indicated the limiting factor of the hollow fiber contactor was the high membrane resistance. In comparison, a flat sheet biocatalytic membrane contactor with lower membrane resistance exhibited much higher CO2 hydration efficiency. It also showed that the enzymatic promotion effect was more evident at low liquid Reynolds number (<50) conditions where many conventional gas-liquid membrane contactors operate, (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 50 条
  • [21] Carbonic Anhydrase Immobilized by ZnO Nanoparticles for Catalytic CO2 Conversion
    Liu, Lian
    Wang, Xin
    Gao, Zixin
    Zhan, Yue
    Yao, Mengqin
    Bao, Jia
    WATER AIR AND SOIL POLLUTION, 2025, 236 (04):
  • [22] Investigation of H2S and CO2 Removal from Gas Streams Using Hollow Fiber Membrane Gas-liquid Contactors
    Mirfendereski, M.
    Mohammadi, T.
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 2017, 31 (02) : 139 - 144
  • [23] Investigation of CO2 removal by immobilized carbonic anhydrase enzyme in a hollow-fiber membrane bioreactor
    Iliuta, Ion
    Iliuta, Maria C.
    AICHE JOURNAL, 2017, 63 (07) : 2996 - 3007
  • [24] ON THE MECHANISM OF ENZYME-CATALYZED GAS-LIQUID REACTIONS - ABSORPTION OF CO2 INTO BUFFER SOLUTIONS CONTAINING CARBONIC-ANHYDRASE
    ALPER, E
    LOHSE, M
    DECKWER, WD
    CHEMICAL ENGINEERING SCIENCE, 1980, 35 (10) : 2147 - 2156
  • [25] Carbonic anhydrase immobilized on Zn(II)-geopolymer membrane for CO 2 capture
    Zhao, Baozhong
    Deng, Xingfa
    He, Yan
    Xiao, Pei
    Dhmees, Abdelghaffar S.
    Cui, Xuemin
    BIOCHEMICAL ENGINEERING JOURNAL, 2024, 208
  • [26] Biocatalytic kinetics of the reaction between CO2 and tertiary amine using carbonic anhydrase
    Du, Meng-Meng
    Wang, Yuan-Cheng
    Sun, Bao-Chang
    Luo, Yong
    Zhang, Liang-Liang
    Chu, Guang-Wen
    Zou, Hai-Kui
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2025, 211
  • [27] Catalytic CO2 hydration by immobilized and free human carbonic anhydrase II in a laminar flow microreactor - Model and simulations
    Iliuta, Ion
    Iliuta, Maria Cornelia
    Larachi, Faical
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 107 : 61 - 69
  • [28] Molecular dynamics simulation for hydration effect on CO2 diffusion in carbonic anhydrase
    Key Laboratory for Industrial Biocatalysis , Department of Chemical Engineering, Tsinghua University, Beijing
    100084, China
    不详
    CA
    92521, United States
    Huagong Xuebao, 8 (2903-2910):
  • [29] CO2 hydration by mimic zinc complex for active site of carbonic anhydrase
    Nakata, K
    Uddin, MK
    Ogawa, K
    Ichikawa, K
    CHEMISTRY LETTERS, 1997, (10) : 991 - 992
  • [30] ELECTROMETRIC ASSAY OF RATE OF HYDRATION OF CO2 FOR INVESTIGATION OF KINETICS OF CARBONIC ANHYDRASE
    CARTER, MJ
    HAVARD, DJ
    PARSONS, DS
    JOURNAL OF PHYSIOLOGY-LONDON, 1969, 204 (02): : P60 - &