Biocatalytic gas-liquid membrane contactors for CO2 hydration with immobilized carbonic anhydrase

被引:52
作者
Hou, Jingwei [1 ]
Zulkifli, Muhammad Yazid [1 ]
Mohammad, Munirah [1 ]
Zhang, Yatao [1 ,2 ]
Razmjou, Amir [1 ,3 ]
Chen, Vicki [1 ]
机构
[1] Univ New South Wales, Sch Chem Engn, UNESCO Ctr Membrane Sci & Technol, Sydney, NSW 2052, Australia
[2] Zhengzhou Univ, Sch Chem Engn & Energy, Zhengzhou 450001, Peoples R China
[3] Univ Isfahan, Fac Adv Sci & Technol, Dept Biotechnol, Esfahan, Iran
基金
澳大利亚研究理事会;
关键词
Gas-liquid membrane contactor; Carbonic anhydrase; TiO2; nanoparticles; Enzyme immobilization; CO2; capture; HOLLOW-FIBER MEMBRANE; MASS-TRANSFER; ABSORPTION; CAPTURE; SEPARATION; SURFACE; DEGRADATION; RESISTANCE;
D O I
10.1016/j.memsci.2016.07.003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
CO2 capture from flue gas, biogas and natural gas is still a key challenge in many environmental and energy applications. The gas-liquid membrane contactor provides a promising alternative to traditional packed towers and bubble columns. We developed a novel biocatalytic gas-liquid membrane contactor for CO2 capture with benign solvent absorbents. Both virgin and superhydrophobic PP hollow fiber membranes were investigated. Biocatalytic TiO2 nanoparticles with covalently immobilized carbonic anhydrase were suspended in the solvent absorbent to promote the CO2 hydration. The immobilized enzyme retained a high degree of the original CO2 hydration efficiency of the free enzyme, and the biocatalytic membrane contactor performance under various industrial-related conditions was investigated, including a wide range of pH and high temperature. Satisfactory reusability of the biocatalytic nanoparticles was exhibited by 10 cycles of repeated use. Finally, the mass transfer study and the Wilson plot indicated the limiting factor of the hollow fiber contactor was the high membrane resistance. In comparison, a flat sheet biocatalytic membrane contactor with lower membrane resistance exhibited much higher CO2 hydration efficiency. It also showed that the enzymatic promotion effect was more evident at low liquid Reynolds number (<50) conditions where many conventional gas-liquid membrane contactors operate, (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:303 / 313
页数:11
相关论文
共 50 条
  • [1] Immobilization of carbonic anhydrase on poly(ionic liquid) composite membranes for CO2 absorption by gas-liquid membrane contactors
    Molina-Fernandez, Cristhian
    Renson, Tom
    Deveen, Victor
    Martin-Chinarro, Carla
    Chaplier, Gauthier
    Vitola, Giuseppe
    Mazzei, Rosalinda
    Giorno, Lidietta
    Luis, Patricia
    JOURNAL OF MEMBRANE SCIENCE, 2023, 687
  • [2] Hybrid enzymatic CO2 capture process in intensified flat sheet membrane contactors with immobilized carbonic anhydrase
    Rasouli, Hannaneh
    Iliuta, Ion
    Bougie, Francis
    Garnier, Alain
    Iliuta, Maria C.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 287
  • [3] Gas-liquid membrane contactors for CO2 removal
    Simons, Katja
    Nijmeijer, Kitty
    Wessling, Matthias
    JOURNAL OF MEMBRANE SCIENCE, 2009, 340 (1-2) : 214 - 220
  • [4] Carbonic anhydrase immobilized on Zn(II)-geopolymer membrane for CO 2 capture
    Zhao, Baozhong
    Deng, Xingfa
    He, Yan
    Xiao, Pei
    Dhmees, Abdelghaffar S.
    Cui, Xuemin
    BIOCHEMICAL ENGINEERING JOURNAL, 2024, 208
  • [5] CO2 hydration by immobilized carbonic anhydrase
    Bhattacharya, S
    Schiavone, M
    Chakrabarti, S
    Bhattacharya, SK
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2003, 38 : 111 - 117
  • [6] Techno-economic assessment of enzymatic CO2 capture in hollow fiber membrane contactors with immobilized carbonic anhydrase
    Nguyen, Kaven
    Iliuta, Ion
    Bougie, Francis
    Pasquier, Louis-Cesar
    Iliuta, Maria C.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 307
  • [7] Investigation of CO2 removal by immobilized carbonic anhydrase enzyme in a hollow-fiber membrane bioreactor
    Iliuta, Ion
    Iliuta, Maria C.
    AICHE JOURNAL, 2017, 63 (07) : 2996 - 3007
  • [8] Deoxygenation of a CO2 Absorbent Based on Monoethanolamine in Gas-Liquid Membrane Contactors: Dynamic Process Modeling
    Kalmykov, D. O.
    Shirokih, S. A.
    Matveev, D. N.
    Petrova, I. V.
    Bazhenov, S. D.
    MEMBRANES AND MEMBRANE TECHNOLOGIES, 2024, 6 (04) : 248 - 258
  • [9] Biocatalytic Janus membranes for CO2 removal utilizing carbonic anhydrase
    Hou, Jingwei
    Ji, Chao
    Dong, Guangxi
    Xiao, Bowen
    Ye, Yun
    Chen, Vicki
    JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (33) : 17032 - 17041
  • [10] Biocatalytic PVDF composite hollow fiber membranes for CO2 removal in gas-liquid membrane contactor
    Xu, Yilin
    Lin, Yuqing
    Chew, Nick Guan Pin
    Malde, Chandresh
    Wang, Rong
    JOURNAL OF MEMBRANE SCIENCE, 2019, 572 : 532 - 544