Experimental approach for breast cancer center estimation using infrared thermography

被引:24
|
作者
Azevedo Figueiredo, Alisson Augusto [1 ]
Fernandes, Henrique Coelho [2 ]
Guimaraes, Gilmar [1 ]
机构
[1] Univ Fed Uberlandia, Sch Mech Engn, BR-38408100 Uberlandia, MG, Brazil
[2] Univ Fed Uberlandia, Sch Comp Sci, BR-38408100 Uberlandia, MG, Brazil
关键词
Breast cancer; Tumor; Thermal images; Infrared camera; Correlation; Inverse problems; PARAMETER-ESTIMATION; TUMORS; TEMPERATURE;
D O I
10.1016/j.infrared.2018.10.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Diagnostics of tumors using thermal cameras are generally conducted in adjuvant examinations because infrared images detect radiation that translates to surface temperature measurements. That is, it is not feasible to detect the location and tumor size using only the direct thermal images. The objective of this work is to develop a new technique that is capable of identifying the coordinates of the geometric center of a tumor present internally in a breast, by using only superficial temperature measurements acquired by an infrared camera. The technique is based on the use of correlations, dimensionless solutions of the temperature field in the breast, and definitions of variables that do not require knowledge of the thermal properties and metabolism of the tissue. Applications of the technique in vitro (phantom tissue sample) are presented. The phantom tissue (silicone) is instrumented with electrical resistances for simulating the internal heat generation effects caused by a tumor. The experimental results demonstrate that the maximum error in the estimation of the tumor depth was 3.82 mm. The technique exhibits high potential for in vivo applications and can be an effective tool for increasing the specificity in detection of breast cancer from IR images.
引用
收藏
页码:100 / 112
页数:13
相关论文
共 50 条
  • [21] Using infrared thermography in the diagnostics of breast and lung oncological pathologies
    Popov, DN
    Vavilova, EV
    MODERN TECHNIQUES AND TECHNOLOGY, 2001, : 148 - 151
  • [22] ESTIMATION OF STILBOSTATR TREATMENT EFFICIENCY IN BREAST-CANCER BY THERMOGRAPHY
    ZIMEL, H
    MOGOS, I
    MALTEZEANU, G
    NEOPLASMA, 1977, 24 (05) : 553 - 557
  • [23] Infrared thermography for wood density estimation
    Lopez, Gamaliel
    Basterra, Luis-Alfonso
    Acuna, Luis
    INFRARED PHYSICS & TECHNOLOGY, 2018, 89 : 242 - 246
  • [24] Accuracy of Infrared Thermography in Diagnosing Breast Cancer-Related Lymphedema
    Gomes, Vanessa Maria da Silva Alves
    Brioschi, Marcos Leal
    da Silva, Ana Rafaela Cardozo
    Tenorio, Naiany
    Oliveira, Laura Raynelle Patriota
    da Silva, Ana Claudia Souza
    Maia, Juliana Netto
    Dantas, Diego
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (20)
  • [25] Infrared Thermography-Based Breast Cancer Detection - Comprehensive Investigation
    Negied, Nermin K.
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2019, 33 (06)
  • [26] Microwaves and Infrared Thermography - Comparative Studies in Early Breast Cancer Detection
    Ojica, S.
    Iftemie, A.
    Rau, M. C.
    Costandache, D.
    Baltag, O.
    2011 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED TOPICS IN ELECTRICAL ENGINEERING (ATEE), 2011,
  • [27] THERMOGRAPHY AND INFRARED PHOTOGRAPHY OF FEMALE BREAST
    ZERMENO, A
    DODD, GD
    MARSH, LM
    BOYD, DR
    PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (01): : 170 - &
  • [28] THERMOGRAPHY AND CANCER OF BREAST
    DODD, GD
    WALLACE, JD
    FREUNDLICH, IM
    MARSH, L
    ZERMINO, A
    CANCER, 1969, 23 (04) : 797 - +
  • [29] THERMOGRAPHY IN BREAST CANCER
    WILLIAMS, KL
    BRITISH JOURNAL OF RADIOLOGY, 1969, 42 (493): : 75 - &
  • [30] DIAGNOSIS OF CARCINOMA OF BREAST BY INFRARED THERMOGRAPHY
    GROS, C
    GAUTHERIE, M
    BOURJAT, P
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1972, 116 (05): : 669 - +