Determination of the glomerular filtration rate in patients with type 2 diabetes: An assessment of the agreement between 51Cr-EDTA plasma clearance and 99mTc-DTPA plasma clearance, 99mTc-DTPA renography and plasma creatinine prediction equation

被引:5
|
作者
Moralidis, Efstratios [1 ]
Papanastasiou, Emmanouil [2 ]
Didangelos, Triantafyllos [3 ]
Hilidis, Ilias [4 ]
Siountas, Anastasios [2 ]
Arsos, Georgios [1 ]
机构
[1] Aristotle Univ Thessaloniki, Papageorgiou Hosp, Dept Nucl Med, Fac Med,Sch Hlth Sci, Ring Rd, Thessaloniki 56429, Greece
[2] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Fac Med, Sch Hlth Sci,Lab Med Phys, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
[3] Aristotle Univ Thessaloniki, AHEPA Univ Hosp, Fac Med, Sch Hlth Sci,Propedeut Dept Internal Med 1, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
[4] AHEPA Univ Hosp, Dept Nucl Med, 1 Stilponos Kyriakidi Str, Thessaloniki 54636, Greece
关键词
Cr-51-EDTA; CKD-EPI; Diabetic nephropathy; Gates' method; Glomerular filtration rate; Tc-99m-DTPA; RENAL CLEARANCE; GFR; SAMPLE; TC-99(M)-DTPA; SCINTIGRAPHY; GUIDELINES; VALUES; INULIN; ACID; DTPA;
D O I
10.1016/j.diabres.2020.108079
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To investigate the agreement of glomerular filtration rate (GFR) determination between Cr-51- ethylenediaminetetraacetic acid (Cr-51- EDTA) plasma clearance (GFR(EDTA)) and Tc-99m-diethylenetriaminepentaacetic acid (Tc-99m-DTPA) plasma clearance (GFR(DTPA)), the Gates Tc-99m- DTPA renographic method (GFRGates) and the serum creatinine Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI, GFR(SCr)) in patients with type 2 diabetes mellitus (T2DM). Methods: Ninety-nine T2DM patients underwent GFR determinations simultaneously with Cr-51-EDTA and Tc-99m-DTPA (using the slope-intercept technique and the Brochner-Mortensen correction) and also with GFR(Gates) and GFR(SCr). Results: In the comparison between GFR(EDTA) versus GFR(DTPA), GFR(Gates) and GFR(SCr), the Bland-Altman statistic provided 0.0 +/- 13.2, 17.4* +/- 28.8 and -5.9* +/- 30.1 (*p < 0.001 for the difference from 0). Lin's concordance correlation coefficient showed substantial (0.976), poor (0.737) and poor (0.872) agreement, respectively. The proportion of the index results within the 30% and 10% of GFR(EDTA) measurements were 95% and 74% for GFR(DTPA), 53% and 19% for GFR(Gates), and 83% and 26% for GFR(SCr), respectively. Conclusion: In T2DM patients, a clinically acceptable agreement is demonstrated between Cr-51-EDTA and Tc-99m-DTPA plasma clearance for GFR measurements, suggesting conditional interchangeability between those compounds. Both the CKD-EPI prediction equation and the Gates' renographic method cannot assess GFR reliably, the latter appearing less unfailing than the former. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 41 条
  • [31] Prediction of renal function improvement in azotemic patients using glomerular filtration rate from 99mTc-DTPA renal scan An observational study
    Yu, Hoon
    Kim, Hyosang
    Shin, Hyung Soo
    Lee, Hyo Sang
    MEDICINE, 2021, 100 (51) : E28332
  • [32] Glomerular filtration rate measured by 99mTc-DTPA renal dynamic imaging is significantly lower than that estimated by the CKD-EPI equation in horseshoe kidney patients
    Qi, Yan
    Hu, Panpan
    Xie, Yuansheng
    Wei, Kai
    Jin, Meiling
    Ma, Guangyu
    Li, Qinggang
    Xu, Baixuan
    Chen, Xiangmei
    NEPHROLOGY, 2016, 21 (06) : 499 - 505
  • [33] Time to complete mixing for the measurement of glomerular filtration rate from single bolus plasma 51Cr-EDTA clearance
    Bird, NJ
    Henderson, BL
    Lui, D
    Peters, M
    NUCLEAR MEDICINE COMMUNICATIONS, 2004, 25 (04) : 393 - 398
  • [34] Comparison of methods for determination of glomerular filtration rate: low and high-dose Tc-99m-DTPA renography, predicted creatinine clearance method, and plasma sample method
    Assadi, Majid
    Eftekhari, Mohammad
    Hozhabrosadati, Mehrdad
    Saghari, Mohsen
    Ebrahimi, Abdolali
    Nabipour, Iraj
    Abbasi, Mohammad Zaki
    Moshtaghi, Darab
    Abbaszadeh, Moloud
    Assadi, Sakineh
    INTERNATIONAL UROLOGY AND NEPHROLOGY, 2008, 40 (04) : 1059 - 1065
  • [35] Comparison of methods for determination of glomerular filtration rate: low and high-dose Tc-99m-DTPA renography, predicted creatinine clearance method, and plasma sample method
    Majid Assadi
    Mohammad Eftekhari
    Mehrdad Hozhabrosadati
    Mohsen Saghari
    Abdolali Ebrahimi
    Iraj Nabipour
    Mohammad Zaki Abbasi
    Darab Moshtaghi
    Moloud Abbaszadeh
    Sakineh Assadi
    International Urology and Nephrology, 2008, 40
  • [36] Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease
    Ma, Ying-Chun
    Zuo, Li
    Zhang, Chun-Li
    Wang, Mei
    Wang, Rong-Fu
    Wang, Hai-Yan
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (02) : 417 - 423
  • [37] 68Ga-EDTA PET/CT Imaging and Plasma Clearance for Glomerular Filtration Rate Quantification: Comparison to Conventional 51Cr-EDTA
    Hofman, Michael
    Binns, David
    Johnston, Val
    Siva, Shankar
    Thompson, Mick
    Eu, Peter
    Collins, Marnie
    Hicks, Rodney J.
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03) : 405 - 409
  • [38] Clinical value of cystatin C and beta-trace protein in glomerular filtration rate in renal transplant cases with stable renal graft functions: comparison by the 99mTc-DTPA plasma sample method
    Oner, Ali Ozan
    Aydin, Funda
    Demirelli, Serkan
    Budak, Evrim S.
    Davran, Fatih
    Akbas, Halide
    Kocak, Huseyin
    Suleymanlar, Gultekin
    Gungor, Firat
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (07) : 733 - 744
  • [39] Modified Schwartz formula and Tc-99m-DTPA plasma clearance methods to calculate glomerular filtration rate in critically ill children
    Bhowmick, Rohit
    Rameshkumar, Ramachandran
    Ponnusamy, Madhusudhanan
    Rajaraman, Vishnukumar
    Chidambaram, Muthu
    Sheriff, Abraar
    Mahadevan, Subramanian
    PEDIATRIC NEPHROLOGY, 2022, 37 (04) : 899 - 906
  • [40] Determination of glomerular filtration rate using a dual-detector gamma camera and the geometric mean of renal activity - Correlation with the Tc-99m DTPA plasma clearance method
    Delpassand, ES
    Homayoon, K
    Madden, T
    Mathai, M
    Podoloff, DA
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (04) : 258 - 262