An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode

被引:77
作者
Gao, Qiang [1 ,2 ]
Guo, Yanyan [1 ]
Zhang, Wenyan [1 ]
Qi, Honglan [1 ,2 ]
Zhang, Chengxiao [1 ,2 ]
机构
[1] Shaanxi Normal Univ, Key Lab Analyt Chem Life Sci Shaanxi Prov, Sch Chem & Mat Sci, Xian 710062, Peoples R China
[2] Shaanxi Normal Univ, Sch Chem & Mat Sci, Minist Educ, Key Lab Appl Surface & Colloid Chem, Xian 710062, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2011年 / 153卷 / 01期
关键词
Glucose biosensor; GOx-SWCNT conjugates; Layer-by-layer assembly; Redox polymer; Screen-printed electrode; DIRECT ELECTROCHEMISTRY; DIFFUSION COEFFICIENTS; TRANSFER KINETICS; ENZYME LAYERS; REDOX POLYMER; CYTOCHROME-C; OXIDASE; NANOTUBE; CONSTRUCTION; ASSEMBLIES;
D O I
10.1016/j.snb.2010.10.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric glucose biosensor based on a multilayer made by layer-by-layer assembly of single-walled carbon nanotubes modified with glucose oxidase (GOx-SWCNT conjugates) and redox polymer (PVI-Os) on a screen-printed carbon electrode (SPCE) surface was developed. The SPCE surface was functionalized with a cationic polymer by electrodeposition of the PVI-Os, followed by alternating immersions in anionic GOx-SWCNT conjugate solutions and cationic PVI-O solutions. The purpose is to build a multilayer structure which is further stabilized through the electrodeposition of PVI-Os on the multilayer film. The electrochemistry of the layer-by-layer assembly of the GOx-SWCNT conjugate/PVI-Os bilayer was followed by cyclic voltammetry. The resultant glucose biosensor provided stable and reproducible electrocatalytic responses to glucose, and the electrocatalytic current for glucose oxidation was enhanced with an increase in the number of bilayers. The glucose biosensor displayed a wide linear range from 0.5 to 8.0 mM, a high sensitivity of 32 mu A mM(-1) cm(-2), and a response time of less than 5 s. The glucose biosensor proved to be promising amperometric detectors for the flow injection analysis of glucose. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:219 / 225
页数:7
相关论文
共 61 条
  • [1] Configurations used in the design of screen-printed enzymatic biosensors.: A review
    Albareda-Sirvent, M
    Merkoçi, A
    Alegret, S
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 69 (1-2) : 153 - 163
  • [2] Electron transfer in organized assemblies of biomolecules.: Step-by-step avidin/biotin construction and dynamic characteristics of a spatially ordered multilayer enzyme electrode
    Anicet, N
    Bourdillon, C
    Moiroux, J
    Savéant, JM
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49): : 9844 - 9849
  • [3] EFFECT OF QUATERNIZATION ON ELECTRON-DIFFUSION COEFFICIENTS FOR REDOX HYDROGELS BASED ON POLY(4-VINYLPYRIDINE)
    AOKI, A
    RAJAGOPALAN, R
    HELLER, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (14) : 5102 - 5110
  • [4] ELECTRON-DIFFUSION COEFFICIENTS IN HYDROGELS FORMED OF CROSS-LINKED REDOX POLYMERS
    AOKI, A
    HELLER, A
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1993, 97 (42) : 11014 - 11019
  • [5] Structure, function, and stability of enzymes covalently attached to single-walled carbon nanotubes
    Asuri, Prashanth
    Bale, Shyam Sundhar
    Pangule, Ravindra C.
    Shah, Dhiral A.
    Kane, Ravi S.
    Dordick, Jonathan S.
    [J]. LANGMUIR, 2007, 23 (24) : 12318 - 12321
  • [6] A superoxide sensor based on a multilayer cytochrome c electrode
    Beissenhirtz, MK
    Scheller, FW
    Lisdat, F
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (16) : 4665 - 4671
  • [7] Enzyme-coated carbon nanotubes as single-molecule biosensors
    Besteman, K
    Lee, JO
    Wiertz, FGM
    Heering, HA
    Dekker, C
    [J]. NANO LETTERS, 2003, 3 (06) : 727 - 730
  • [8] Protein-sensing assay formats and devices
    Bilitewski, Ursula
    [J]. ANALYTICA CHIMICA ACTA, 2006, 568 (1-2) : 232 - 247
  • [9] STEP-BY-STEP IMMUNOLOGICAL CONSTRUCTION OF A FULLY ACTIVE MULTILAYER ENZYME ELECTRODE
    BOURDILLON, C
    DEMAILLE, C
    MOIROUX, J
    SAVEANT, JM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (22) : 10328 - 10329
  • [10] From homogeneous electroenzymatic kinetics to antigen-antibody construction and characterization of spatially ordered catalytic enzyme assemblies on electrodes
    Bourdillon, C
    Demaille, C
    Moiroux, J
    Saveant, JM
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1996, 29 (11) : 529 - 535