Determination of five antiarrhythmic drugs in human plasma by dispersive liquid-liquid microextraction and high-performance liquid chromatography

被引:64
作者
Jouyban, Abolghasem [1 ,2 ]
Sorouraddin, Mohammad Hossein [3 ]
Farajzadeh, Mir Ali [3 ]
Somi, Mohammad Hossein [4 ]
Fazeli-Bakhtiyari, Rana [3 ,4 ]
机构
[1] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[3] Univ Tabriz, Fac Chem, Dept Analyt Chem, Tabriz, Iran
[4] Tabriz Univ Med Sci, Liver & Gastrointestinal Dis Res Ctr, Tabriz, Iran
关键词
Dispersive liquid-liquid microextraction; High-performance liquid chromatography-ultraviolet; Method validation; Antiarrhythmic drugs; Plasma; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; CAPILLARY-ZONE-ELECTROPHORESIS; FLOATING ORGANIC DROPLET; BETA-BLOCKER DRUGS; HUMAN URINE; CARDIOVASCULAR DRUGS; GAS-CHROMATOGRAPHY; SCREENING METHOD; DOPING AGENTS;
D O I
10.1016/j.talanta.2014.12.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast and sensitive high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection was developed and validated for the simultaneous quantitation of five antiarrhythmic drugs (metoprolol, propranolol, carvedilol, diltiazem, and verapamil) in human plasma samples. It involves dispersive liquid-liquid microextraction (DLLME) of the desired drugs from 660 mu L plasma and separation using isocratic elution with UV detection at 200 nm. The complete separation of all analytes was achieved within 7 min. Acetonitrile (as disperser solvent) resulting from the protein precipitation procedure was mixed with 100 mu L dichloromethane (as an extraction solvent) and rapidly injected into 5 mL aqueous solution (pH 11.5) containing 1% (w/v), NaCl. After centrifugation, the sedimented phase containing enriched analytes was collected and evaporated to dryness. The residue was re-dissolved in 50 mu L deionized water (acidified to pH 3) and injected into the HPLC system for analysis. Under the optimal conditions, the enrichment factors and extraction recoveries ranged between 4.4-10.8 and 33-82%, respectively. The suggested method was linear (r(2) >= 0.997) over a dynamic range of 0.02-0.80 mu g mL(-1) in plasma. The intra- and inter-days relative standard deviation (RSD%) and relative error (RE%) values of the method were below 20%, which shows good precision and accuracy. Finally, this method was applied to the analysis of real plasma samples obtained from the patients treated with these drugs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:681 / 689
页数:9
相关论文
共 52 条
  • [1] Ashri NY, 2011, BIOANALYSIS, V3, P2003, DOI [10.4155/bio.11.201, 10.4155/BIO.11.201]
  • [2] UHPLC method for the simultaneous determination of β-blockers, isoflavones and their metabolites in human urine
    Baranowska, Irena
    Magiera, Sylwia
    Baranowski, Jacek
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (9-10): : 615 - 626
  • [3] Optimization of mobile phase in the separation of β-blockers by HPLC
    Basci, NE
    Temizer, A
    Bozkurt, A
    Isimer, A
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) : 745 - 750
  • [4] Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry - An application for bioequivalence study
    Borges, NCD
    Mendes, GD
    Barrientos-Astigarraga, RE
    Galvinas, P
    Oliveira, CH
    De Nucci, G
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 827 (02): : 165 - 172
  • [5] DEVELOPMENT AND VALIDATION OF A BIOANALYTICAL METHOD FOR THE QUANTIFICATION OF DILTIAZEM AND DESACETYLDILTIAZEM IN PLASMA BY CAPILLARY ZONE ELECTROPHORESIS
    COORS, C
    SCHULZ, HG
    STACHE, F
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1995, 717 (1-2) : 235 - 243
  • [6] Simultaneous determination of thirteen β-blockers and one metabolite by gradient high-performance liquid chromatography with photodiode-array UV detection
    Delamoye, M
    Duverneuil, C
    Paraire, F
    de Mazancourt, P
    Alvarez, JC
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2004, 141 (01) : 23 - 31
  • [7] Simultaneous determination of beta-blocking agents and diuretics in doping analysis by liquid chromatography mass spectrometry with scan-to-scan polarity switching
    Deventer, K
    Van Eenoo, P
    Delbeke, FT
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) : 90 - 98
  • [8] An LC-MS assay for the screening of cardiovascular medications in human samples
    Dias, Eduardo
    Hachey, Brian
    McNaughton, Candace
    Nian, Hui
    Yu, Chang
    Straka, Brittany
    Brown, Nancy J.
    Caprioli, Richard M.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 937 : 44 - 53
  • [9] Determination of three β-blockers in biofluids and solid tissues by liquid chromatography-electrospray-mass spectrometry
    Dupuis, C
    Gaulier, JM
    Pélissier-Alicot, AL
    Marquet, P
    Lachâtre, U
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (08) : 674 - 679
  • [10] Farhadi K, 2013, BIOANALYSIS, V5, P701, DOI [10.4155/BIO.13.23, 10.4155/bio.13.23]