Analysis of Corona Discharge in Wire-cylinder ESP with and without Particle Loading

被引:5
|
作者
Abdel-Salam, M. [1 ]
EI-Mohandes, M. Th. [1 ]
El-deen, S. Kama [1 ]
机构
[1] Assiut Univ, Dept Elect Engn, Assiut, Egypt
关键词
Electrostatic precipitator; corona discharge; particle loading; electric field; Poisson's equations; ELECTRICAL CONDITIONS; ELECTROSTATIC-FIELD; FINITE-ELEMENT; CHARGE; PRECIPITATORS; COMPUTATION; SIMULATION; VOLTAGE;
D O I
10.1109/TDEI.2016.7736818
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is aimed at investigating thoroughly the corona performance in the wire-cylinder ESP with and without loading by suspended particles in the exhaust of a diesel engine. The onset voltage of negative corona on the discharge wire is calculated based on the criterion of self-sustained discharge. The ionized space between the discharge wire and the collecting cylinder of the ESP is mathematically modeled for calculating the spatial distribution of the space-charge density due to both the ions and the charged particles as well as the components of the electric field including the applied field and the field due to the space charge. This is in addition to the calculation of the current-voltage characteristics of the ESP with and without particle loading.
引用
收藏
页码:2607 / 2616
页数:10
相关论文
共 50 条
  • [1] Corona Performance in Wire-cylinder ESP without Particle Loading
    El-Mohandes, Mohamed Th.
    Abdel-Salam, Mazen
    El-deen, Seham Kamal
    2016 ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2016), 2016, 55
  • [2] Corona Performance in Wire-cylinder ESP with Particle Loading
    Abdel-Salam, Mazen
    El-Mohandes, Mohamed Th.
    El-deen, Seham Kamal
    2016 ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2016), 2016, 55
  • [3] WIRE-CYLINDER CORONA DISCHARGE WITH THE WIRE AT POSITIVE POTENTIAL
    GOVINDARAJU, GR
    GURUMURTHY, GR
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1979, 46 (05) : 497 - 506
  • [4] Numerical modelling of ozone production in a wire-cylinder corona discharge and comparison with a wire-plate corona discharge
    Wang, Pengxiang
    Chen, Junhong
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2009, 42 (03)
  • [5] Current analysis of DC negative corona discharge in a wire-cylinder configuration at high ambient temperatures
    Xiao, Gang
    Wang, Xihui
    Zhang, Jiapeng
    Ni, Mingjiang
    Gao, Xiang
    Cen, Kefa
    JOURNAL OF ELECTROSTATICS, 2014, 72 (02) : 107 - 119
  • [6] Experimental Study of the Corona Discharge in a Modified Coaxial Wire-Cylinder Electrostatic Precipitator
    Blejan, O.
    Notingher, P.
    Dumitran, L. M.
    Younes, M.
    Samuila, A.
    Dascalescu, L.
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 1111 - +
  • [7] Experimental Study of the Corona Discharge in a Modified Coaxial Wire-Cylinder Electrostatic Precipitator
    Blejan, Octavian
    Notingher, Petru V.
    Dumitran, Laurentiu Marius
    Younes, Mohamed
    Samuila, Adrian
    Dascalescu, Lucian
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (01) : 3 - 8
  • [8] Influence of Magnetic Field on Characteristics of Corona Discharge in Wire-Cylinder Electrodes Configuration
    Wais, Sabah Ibrahim
    Mohammed, Pirzheen Ageed
    PLASMA, 2021, 4 (04) : 764 - 779
  • [9] Development of back corona discharge in a wire-cylinder electrostatic precipitator at high temperatures
    Ni, Mingjiang
    Wang, Xihui
    Xiao, Gang
    Qiu, Kunzan
    Yang, Guang
    Gao, Xiang
    Cen, Kefa
    POWDER TECHNOLOGY, 2015, 286 : 789 - 797
  • [10] An analytical method for DC negative corona discharge in a wire-cylinder device at high temperatures
    Wang, Xihui
    Ni, Mingjiang
    Xiao, Gang
    Zhang, Jiapeng
    Gao, Xiang
    Cen, Kefa
    JOURNAL OF ELECTROSTATICS, 2014, 72 (04) : 270 - 284