Optimization of Multi-Target Sample Preparation On-Demand With Digital Microfluidic Biochips

被引:7
|
作者
Poddar, Sudip [1 ,2 ]
Bhattacharjee, Sukanta [3 ]
Nandy, Subhas C. [1 ]
Chakrabarty, Krishnendu [4 ]
Bhattacharya, Bhargab B. [1 ]
机构
[1] Indian Stat Inst, Adv Comp & Microelect Unit, Kolkata 700108, India
[2] Indian Inst Engn Sci & Technol, Sch VLSI Technol, Sibpur 711103, Howrah, India
[3] New York Univ Abu Dhabi, Ctr Cyber Secur, Abu Dhabi 129188, U Arab Emirates
[4] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
关键词
Digital microfluidic biochip (DMFB); multiple dilutions; sample preparation; BIOCHEMICAL SAMPLES; REACTANT MINIMIZATION; DILUTION; CELL; BIOASSAY; TECHNOLOGIES; ALGORITHM; DESIGN;
D O I
10.1109/TCAD.2018.2808234
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Sample preparation is a fundamental preprocessing step needed in almost all biochemical assays and is conveniently automated on a microfluidic lab-on-chip. In digital microfluidics, it is accomplished by a sequence of droplet-mix-split steps on a biochip. Many real-life applications require a sample with multiple concentration factors (CFs). Existing algorithms, while producing multi-CF targets, attempt to share the mix-split steps in order to reduce reactant-cost and sample-preparation time. However, all prior approaches have two limitations: 1) sharing of intermediate droplets can be best effected only when all required target CFs are known a priori and 2) the processing time may vary depending on the allowable error-tolerance in target-CFs. In this paper, we present a cost-effective solution to multi-CF-dilution on-demand, by using only one (or two) mix-split step(s). In order to service dynamically arriving requests of multiple CFs quickly, we prepare dilutions of the sample with a few CFs in advance (called source-CFs), and fill on-chip reservoirs with these fluids. For minimizing the number of such preprocessed CFs, we present an integer linear programming-based method, an approximation algorithm, and a heuristic algorithm. The proposed methods also allow the users to tradeoff the number of on-chip reservoirs against service time for various applications. Simulation results for several target sets demonstrate the superiority of the proposed techniques over prior art in terms of the number of mix-split steps, waste droplets, and reactant usage when the on-chip reservoirs are preloaded with source-CFs using a customized droplet-streaming engine.
引用
收藏
页码:253 / 266
页数:14
相关论文
共 50 条
  • [31] LUTOSAP: Lookup Table Based Online Sample Preparation in Microfluidic Biochips
    Shao, Lingxuan
    Yang, Yibin
    Yao, Hailong
    Ho, Tsung-Yi
    Cai, Yici
    PROCEEDINGS OF THE GREAT LAKES SYMPOSIUM ON VLSI 2017 (GLSVLSI' 17), 2017, : 447 - 450
  • [32] Sample Preparation with Free-Flowing Biochips Using Microfluidic Binary-Tree Network
    Banerjee, Tapalina
    Poddar, Sudip
    Bhattacharjee, Sukanta
    Song, Yong-Ak
    Orozaliev, Ajymurat
    Bhattacharya, Bhargab B.
    2020 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2020,
  • [33] Error-Oblivious Sample Preparation with Digital Microfluidic Lab-on-Chip
    Poddar, Sudip
    Wille, Robert
    Rahman, Hafizur
    Bhattacharya, Bhargab B.
    IEEE TRANSACTIONS ON COMPUTER-AIDED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2019, 38 (10) : 1886 - 1899
  • [34] Exact Synthesis of Biomolecular Protocols for Multiple Sample Pathways on Digital Microfluidic Biochips
    Keszocze, Oliver
    Ibrahim, Mohamed
    Wille, Robert
    Chakrabarty, Krishnendu
    Drechsler, Rolf
    2018 31ST INTERNATIONAL CONFERENCE ON VLSI DESIGN AND 2018 17TH INTERNATIONAL CONFERENCE ON EMBEDDED SYSTEMS (VLSID & ES), 2018, : 121 - 126
  • [35] Weighted optimization of various parameters for droplet routing in digital microfluidic biochips
    Pan, Indrajit
    Samanta, Tuhina
    Advances in Intelligent Systems and Computing, 2014, 235 : 131 - 139
  • [36] A Multi-Objective-Driven Placement Technique for Digital Microfluidic Biochips
    Wan, Chaowei
    Chen, Xiaodao
    Liu, Dongbo
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2019, 28 (05)
  • [37] Droplet Size-Aware and Error-Correcting Sample Preparation Using Micro-Electrode-Dot-Array Digital Microfluidic Biochips
    Li, Zipeng
    Lai, Kelvin Yi-Tse
    Chakrabarty, Krishnendu
    Ho, Tsung-Yi
    Lee, Chen-Yi
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2017, 11 (06) : 1380 - 1391
  • [38] Multi-terminal PCB Escape Routing for Digital Microfluidic Biochips using Negotiated Congestion
    McDaniel, Jeffrey
    Grissom, Daniel
    Brisk, Philip
    2014 22ND INTERNATIONAL CONFERENCE ON VERY LARGE SCALE INTEGRATION (VLSI-SOC), 2014,
  • [39] Distributed Scan Like Fault Detection and Test Optimization for Digital Microfluidic Biochips
    Mukherjee, Subhamita
    Samanta, Tuhina
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2015, 31 (03): : 311 - 319
  • [40] Scheduling algorithms for reservoir- and mixer-aware sample preparation with microfluidic biochips
    Agarwal, Varsha
    Singla, Ananya
    Samiuddin, Mahammad
    Roy, Sudip
    Ho, Tsung-Yi
    Sengupta, Indranil
    Bhattacharya, Bhargab B.
    INTEGRATION-THE VLSI JOURNAL, 2019, 65 : 428 - 443