Optimization of Multi-Target Sample Preparation On-Demand With Digital Microfluidic Biochips

被引:7
|
作者
Poddar, Sudip [1 ,2 ]
Bhattacharjee, Sukanta [3 ]
Nandy, Subhas C. [1 ]
Chakrabarty, Krishnendu [4 ]
Bhattacharya, Bhargab B. [1 ]
机构
[1] Indian Stat Inst, Adv Comp & Microelect Unit, Kolkata 700108, India
[2] Indian Inst Engn Sci & Technol, Sch VLSI Technol, Sibpur 711103, Howrah, India
[3] New York Univ Abu Dhabi, Ctr Cyber Secur, Abu Dhabi 129188, U Arab Emirates
[4] Duke Univ, Dept Elect & Comp Engn, Durham, NC 27708 USA
关键词
Digital microfluidic biochip (DMFB); multiple dilutions; sample preparation; BIOCHEMICAL SAMPLES; REACTANT MINIMIZATION; DILUTION; CELL; BIOASSAY; TECHNOLOGIES; ALGORITHM; DESIGN;
D O I
10.1109/TCAD.2018.2808234
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Sample preparation is a fundamental preprocessing step needed in almost all biochemical assays and is conveniently automated on a microfluidic lab-on-chip. In digital microfluidics, it is accomplished by a sequence of droplet-mix-split steps on a biochip. Many real-life applications require a sample with multiple concentration factors (CFs). Existing algorithms, while producing multi-CF targets, attempt to share the mix-split steps in order to reduce reactant-cost and sample-preparation time. However, all prior approaches have two limitations: 1) sharing of intermediate droplets can be best effected only when all required target CFs are known a priori and 2) the processing time may vary depending on the allowable error-tolerance in target-CFs. In this paper, we present a cost-effective solution to multi-CF-dilution on-demand, by using only one (or two) mix-split step(s). In order to service dynamically arriving requests of multiple CFs quickly, we prepare dilutions of the sample with a few CFs in advance (called source-CFs), and fill on-chip reservoirs with these fluids. For minimizing the number of such preprocessed CFs, we present an integer linear programming-based method, an approximation algorithm, and a heuristic algorithm. The proposed methods also allow the users to tradeoff the number of on-chip reservoirs against service time for various applications. Simulation results for several target sets demonstrate the superiority of the proposed techniques over prior art in terms of the number of mix-split steps, waste droplets, and reactant usage when the on-chip reservoirs are preloaded with source-CFs using a customized droplet-streaming engine.
引用
收藏
页码:253 / 266
页数:14
相关论文
共 50 条
  • [21] Reactant and Waste Minimization during Sample Preparation on Micro-Electrode-Dot-Array Digital Microfluidic Biochips using Splitting Trees
    Dong, Chen
    Chen, Xiao
    Chen, Zhenyi
    JOURNAL OF ELECTRONIC TESTING-THEORY AND APPLICATIONS, 2024, 40 (01): : 87 - 99
  • [22] ILP-Based Synthesis for Sample Preparation Applications on Digital Microfluidic Biochips
    Yadav, Abhimanyu
    Trung Anh Dinh
    Kitagawa, Daiki
    Yamashita, Shigeru
    2016 29TH INTERNATIONAL CONFERENCE ON VLSI DESIGN AND 2016 15TH INTERNATIONAL CONFERENCE ON EMBEDDED SYSTEMS (VLSID), 2016, : 355 - 360
  • [23] Design Automation of Multiple-Demand Mixture Preparation using a K-Array Rotary Mixer on Digital Microfluidic Biochips
    Kumar, Satendra
    Gupta, Ankur
    Roy, Sudip
    Bhattacharya, Bhargab B.
    PROCEEDINGS OF THE 34TH IEEE INTERNATIONAL CONFERENCE ON COMPUTER DESIGN (ICCD), 2016, : 273 - 280
  • [24] Layout-Aware Mixture Preparation of Biochemical Fluids on Application-Specific Digital Microfluidic Biochips
    Roy, Sudip
    Chakrabarti, Partha P.
    Kumar, Srijan
    Chakrabarty, Krishnendu
    Bhattacharya, Bhargab B.
    ACM TRANSACTIONS ON DESIGN AUTOMATION OF ELECTRONIC SYSTEMS, 2015, 20 (03)
  • [25] Multi-target Fluid Mixing in MEDA Biochips: Theory and an Attempt toward Waste Minimization
    Kundu, Debraj
    Roy, Sudip
    ACM TRANSACTIONS ON DESIGN AUTOMATION OF ELECTRONIC SYSTEMS, 2023, 28 (06)
  • [26] Volume-Oriented Sample Preparation for Reactant Minimization on Flow-Based Microfluidic Biochips with Multi-Segment Mixers
    Huang, Chi-Mei
    Liu, Chia-Hung
    Huang, Juinn-Dar
    2015 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2015, : 1114 - 1119
  • [27] Reactant and Waste Minimization during Sample Preparation on Micro-Electrode-Dot-Array Digital Microfluidic Biochips using Splitting Trees
    Chen Dong
    Xiao Chen
    Zhenyi Chen
    Journal of Electronic Testing, 2024, 40 : 87 - 99
  • [28] Algorithms for Sample and Waste-Aware Multiple Concentration Dilution Preparation with Digital Microfluidic Biochips
    Das, Kunal
    Podder, Dipannita
    De, Mallika
    IETE JOURNAL OF RESEARCH, 2017, 63 (04) : 482 - 492
  • [29] An Evolutionary Multi-objective Optimization algorithm for the routing of droplets in Digital Microfluidic Biochips
    Juarez, Julio
    Brizuela, Carlos A.
    Martinez-Perez, Israel M.
    INFORMATION SCIENCES, 2018, 429 : 130 - 146
  • [30] Waste-aware single-target dilution of a biochemical fluid using digital microfluidic biochips
    Roy, Sudip
    Chakrabarti, Partha P.
    Chakrabarty, Krishnendu
    Bhattacharya, Bhargab B.
    INTEGRATION-THE VLSI JOURNAL, 2015, 51 : 194 - 207