The Talk Test and its relationship with the ventilatory and lactate thresholds

被引:30
作者
Quinn, Timothy J. [1 ]
Coons, Benjamin A. [1 ]
机构
[1] Univ New Hampshire, Dept Kinesiol, Robert Kertzer Exercise Physiol Lab, Durham, NH 03824 USA
关键词
Exercise intensity; anaerobic threshold; exercise testing; exercise training; ANAEROBIC THRESHOLD; BLOOD LACTATE; EXERCISE PRESCRIPTION; PERCEIVED EXERTION; INTENSITY; PROTOCOL; DENSITY;
D O I
10.1080/02640414.2011.585165
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
In this study, we wished to determine the relationship between the Talk Test physiological and perceptual indicators and variables measured at the ventilatory and lactate thresholds, and if the Talk Test indicators were associated with a typical exercise prescription. Fifteen participants (13 males and 2 females; age 18-35 years) underwent a treadmill lactate threshold test followed by a (V) over dotO(2max) (maximal oxygen consumption) test in which the ventilatory threshold was determined. On a separate day, a Talk Test was administered in which participants read a passage during exercise and rated speaking comfort: "comfortable" (+Talk Test), "not sure" (+/-Talk Test), or "not able to speak comfortably" (-Talk Test). Exercise prescriptions based on 65% and 80% of heart rate reserve and (V) over dotO(2) reserve were determined. Lactate threshold values were significantly higher than those at the ventilatory threshold (P < 0.05). The heart rate, (V) over dotO(2), and %(V) over dotO(2max) recorded at all levels of the Talk Test were significantly higher than similar measurements recorded at the ventilatory threshold (P < 0.05). Lactate threshold measurements were similar to the +Talk Test and +/-Talk Test. Participants were exercising at 64 +/- 5% (V) over dotO(2max), 82 +/- 7% maximal heart rate, and 12 +/- 2% RPE (rating of perceived exertion) at the +Talk Test, and 71 +/- 6% (V) over dotO(2max), 90 +/- 6% maximal heart rate, and 15 +/- 2% RPE at the +/-Talk Test, with all values being within ACSM exercise intensity guidelines. Therefore, the Talk Test can be used in this population to prescribe exercise, and Talk Test data are more strongly related to physiological and perceptual variables corresponding to the lactate threshold than to the ventilatory threshold.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 50 条
  • [41] Heart Rate Variability-Derived Thresholds for Exercise Intensity Prescription in Endurance Sports: A Systematic Review of Interrelations and Agreement with Different Ventilatory and Blood Lactate Thresholds
    Sebastian Kaufmann
    Thomas Gronwald
    Fabian Herold
    Olaf Hoos
    Sports Medicine - Open, 9
  • [42] Setting Treadmill Intensity for Rat Aerobic Training Using Lactate and Gas Exchange Thresholds
    Inoue, Koshiro
    Soya, Hideaki
    Murakumo, Kei
    Araki, Yusuke
    Hiraga, Taichi
    Soya, Shingo
    Okamoto, Masahiro
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2025, 57 (02) : 434 - 446
  • [43] Eccentric exercise-induced muscle damage dissociates the lactate and gas exchange thresholds
    Davies, Rosemary C.
    Rowlands, Ann V.
    Poole, David C.
    Jones, Andrew M.
    Eston, Roger G.
    JOURNAL OF SPORTS SCIENCES, 2011, 29 (02) : 181 - 189
  • [44] Reliability and Validity of Tethered Swimming Lactate Minimum Test and Their Relationship With Performance in Young Swimmers
    Kalva-Filho, Carlos Augusto
    Toubekis, Argyris
    Zagatto, Alessandro Moura
    Ramos da Silva, Adelino Sanchez
    Loures, Joao Paulo
    Campos, Eduardo Zapaterra
    Papoti, Marcelo
    PEDIATRIC EXERCISE SCIENCE, 2018, 30 (03) : 383 - 392
  • [45] ACCURACY OF A MODIFIED LACTATE MINIMUM TEST AND REVERSE LACTATE THRESHOLD TEST TO DETERMINE MAXIMAL LACTATE STEADY STATE
    Wahl, Patrick
    Manunzio, Christian
    Vogt, Florian
    Struett, Sarah
    Volmary, Prisca
    Bloch, Wilhelm
    Mester, Joachim
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (12) : 3489 - 3496
  • [46] EFFECTS OF SPEECH PASSAGE LENGTH ON ACCURACY OF PREDICTING METABOLIC THRESHOLDS USING THE TALK TEST
    Schroeder, Megan M.
    Foster, Carl
    Porcari, John P.
    Mikat, Richard P.
    KINESIOLOGY, 2017, 49 (01) : 9 - 14
  • [47] Is the Tyme Wear Smart Shirt Reliable and Valid at Detecting Personalized Ventilatory Thresholds in Recreationally Active Individuals?
    Gouw, Aaron H.
    Van Guilder, Gary P.
    Cullen, Gillian G.
    Dalleck, Lance C.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (03)
  • [48] Validity of the Talk Test as a Method to Estimate Ventilatory Threshold and Guide Exercise Intensity in Cardiac Patients
    Sorensen, Lotte
    Larsen, Karoline Stentoft Rybjerg
    Petersen, Annemette Krintel
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2020, 40 (05) : 330 - 334
  • [49] Heart rate variability to assess ventilatory thresholds in professional basketball players
    Domingo Jesús Ramos-Campo
    Jacobo A.Rubio-Arias
    Vicente ávila-Gandía
    Cristian Marín-Pagán
    Antonio Luque
    Pedro E.Alcaraz
    JournalofSportandHealthScience, 2017, 6 (04) : 468 - 473
  • [50] Heart rate variability to assess ventilatory thresholds: reliable in cardiac disease?
    Mourot, L.
    Tordi, N.
    Bouhaddi, M.
    Teffaha, D.
    Monpere, C.
    Regnard, J.
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2012, 19 (06) : 1272 - 1280