Aptamer-Based Traceless Multiplexed Cell Isolation Systems

被引:7
|
作者
Cheng, Emmeline L. [1 ]
Kacherovsky, Nataly [1 ]
Pun, Suzie H. [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
关键词
aptamer; reversible binding; cell isolation; strand displacement; immunomagnetic separation; AFFINITY PEPTIDE; T-CELLS; SEPARATION; LIGANDS; BINDING; PURIFICATION; LYMPHOCYTES; MULTIMERS; SELECTION; KINETICS;
D O I
10.1021/acsami.2c11783
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In both biomedical research and clinical cell therapy manufacturing, there is a need for cell isolation systems that recover purified cells in the absence of any selection agent. Reported traceless cell isolation methods using engineered antigen-binding fragments or aptamers have been limited to processing a single cell type at a time. There remains an unmet need for cell isolation processes that rapidly sort multiple target cell types. Here, we utilized two aptamers along with their designated complementary strands (reversal agents) to tracelessly isolate two cell types from a mixed cell population with one aptamer-labeling step and two sequential cell elution steps with reversal agents. We engineered a CD71-binding aptamer (rvCD71apt) and a reversal agent pair to be used simultaneously with our previously reported traceless purification approach using the CD8 aptamer (rvCD8apt) and its reversal agent. We verified the compatibility of the two aptamer displacement mechanisms by flow cytometry and the feasibility of incorporating rvCD71apt with a magnetic solid state. We then combined rvCD71apt with rvCD8apt to isolate activated CD4+T cells and resting CD8+cells by eluting these target cells into separate fractions with orthogonal strand displacements. This is the first demonstration of isolating different cell types using two aptamers and reversal agents at the same time. Potentially, different or more aptamers can be included in this traceless multiplexed isolation system for diverse applications with a shortened operation time and a lower production cost. © 2022 American Chemical Society. All rights reserved.
引用
收藏
页码:44136 / 44146
页数:11
相关论文
共 50 条
  • [21] Aptamer-based stem cell technology for improving the hemocompatibility
    Hoffmann, J.
    Paul, A.
    Ziemer, G.
    Wendel, H. P.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2007, 21 (04): : 148 - 155
  • [22] DNA aptamer-based nanomaterial for targeted cell labeling
    Zhou, Jing
    Soontornworajit, Boonchoy
    Wang, Yong
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238
  • [23] A review of advances in aptamer-based cell detection technology
    Chen, Wenrong
    Liu, Fuguo
    Zhang, Chunyun
    Duan, Yu
    Ma, Jinju
    Wang, Yuanyuan
    Chen, Guofu
    MOLECULAR BIOLOGY REPORTS, 2023, 50 (06) : 5425 - 5438
  • [24] Target-Specific Exosome Isolation through Aptamer-Based Microfluidics
    Zhou, Zixuan
    Chen, Yan
    Qian, Xiang
    BIOSENSORS-BASEL, 2022, 12 (04):
  • [25] Aptamer-based microfluidics for isolation, release and analysis of circulating tumor cells
    Wu, Lingling
    Zhu, Lin
    Huang, Mengjiao
    Song, Jia
    Zhang, Huimin
    Song, Yanling
    Wang, Wei
    Yang, Chaoyong
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 117 : 69 - 77
  • [26] An aptamer-based protein biochip
    Stadtherr, K
    Wolf, H
    Lindner, P
    ANALYTICAL CHEMISTRY, 2005, 77 (11) : 3437 - 3443
  • [27] Aptamer-Based Diagnostics and Therapeutics
    Shigdar, Sarah
    PHARMACEUTICALS, 2019, 12 (01)
  • [28] Aptamer-based molecular imaging
    Wang, Tianjiao
    Ray, Judhajeet
    PROTEIN & CELL, 2012, 3 (10) : 739 - 754
  • [29] Electrochemical aptamer-based biosensors
    Kim, Yeon Seok
    Lee, Su Jin
    Gu, Man Bock
    BIOCHIP JOURNAL, 2008, 2 (03) : 175 - 182
  • [30] Aptamer-Based Microfluidic Biosensors
    Lin, Qiao
    Thaihuu Nguyen
    2009 9TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2009, : 812 - 814