A Double-Benefit Moving Target Defense Against Cyber-Physical Attacks in Smart Grid

被引:14
作者
Zhang, Zhenyong [1 ,2 ,3 ]
Tian, Youliang [1 ,2 ]
Deng, Ruilong [3 ,4 ]
Ma, Jianfeng [5 ,6 ]
机构
[1] Guizhou Univ, State Key Lab Publ Big Data, Guiyang 550025, Peoples R China
[2] Guizhou Univ, Coll Comp Sci & Technol, Guiyang 550025, Peoples R China
[3] Zhejiang Univ, Coll Control Sci & Engn, Hangzhou 310027, Peoples R China
[4] Zhejiang Univ, State Key Lab Ind Control Technol, Hangzhou 310027, Peoples R China
[5] Guizhou Univ, Coll State Key Lab Publ Big Data Comp Sci & Techn, Guiyang 550025, Peoples R China
[6] Xidian Univ, Sch Comp Sci & Technol, Xian 710071, Peoples R China
基金
中国国家自然科学基金;
关键词
Cyber-physical attack (CPA); deployment cost; moving target defense (MTD); smart grid (SG) security; FALSE DATA INJECTION; STATE ESTIMATION; POWER GRIDS; SYSTEMS; SECURITY; FACTS;
D O I
10.1109/JIOT.2022.3161790
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The smart grid (SG), as one of the largest evolutionary critical infrastructures, witnesses the deep integration of electricity facilities and Internet of Things (IoT). But recent events show that the vulnerabilities exposed in IoT devices can be exploited by adversaries to construct the cyberattacks on SG. To address this threat, plenty of countermeasures have been proposed to enhance the SG's security. However, the additional costs introduced by some countermeasures make the utilities hesitate to implement them practically. To alleviate this concern, in this article, we propose a double-benefit moving target defense (dB-MTD) to protect the SG from cyber-physical attacks (CPAs) and also gain generation-cost benefits. The dB-MTD enables the prevention of stealthy CPAs on the transmission lines by perturbing the reactances with the distributed flexible AC transmission system (D-FACTS). To reduce the infrastructure cost, we minimize the number of required D-FACTS devices for a specific protection goal. Although it needs investment on D-FACTS, we find that the utility can make profits from the generation costs by appropriately setting the reactance perturbations. Therefore, we formulate an optimization problem to compute the optimal reactance perturbations to maximize the generation-cost benefits, without sacrificing the protection performance of dB-MTD. Finally, using the real-world load profiles, we conduct extensive simulations to evaluate the impact of CPA on the system operation and the benefits obtained by the dB-MTD from the aspects of the D-FACTS deployment and the generation-cost profits.
引用
收藏
页码:17912 / 17925
页数:14
相关论文
共 50 条
  • [21] Leveraging Network Topology Optimization to Strengthen Power Grid Resilience Against Cyber-Physical Attacks
    Liu, Zhaoxi
    Wang, Lingfeng
    IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (02) : 1552 - 1564
  • [22] Cyber-Physical Security of a Smart Grid Infrastructure
    Mo, Yilin
    Kim, Tiffany Hyun-Jin
    Brancik, Kenneth
    Dickinson, Dona
    Lee, Heejo
    Perrig, Adrian
    Sinopoli, Bruno
    PROCEEDINGS OF THE IEEE, 2012, 100 (01) : 195 - 209
  • [23] Cyber-physical risk assessment for false data injection attacks considering moving target defences Best practice application of respective cyber and physical reinforcement assets to defend against FDI attacks
    Higgins, Martin
    Xu, Wangkun
    Teng, Fei
    Parisini, Thomas
    INTERNATIONAL JOURNAL OF INFORMATION SECURITY, 2023, 22 (03) : 579 - 589
  • [24] Moving Target Defense for Detecting Coordinated Cyber-Physical Attacks on Power Grids via a Modified Sensor Measurement Expression
    Yu, Jian
    Li, Qiang
    ELECTRONICS, 2023, 12 (07)
  • [25] Smart Grid Cyber-Physical Situational Awareness of Complex Operational Technology Attacks: A Review
    Nafees, Muhammad Nouman
    Saxena, Neetesh
    Cardenas, Alvaro
    Grijalva, Santiago
    Burnap, Pete
    ACM COMPUTING SURVEYS, 2023, 55 (10)
  • [26] Cyber-attacks against cyber-physical power systems security: State estimation, attacks reconstruction and defense strategy
    Su, Qingyu
    Wang, Handong
    Sun, Chaowei
    Li, Bo
    Li, Jian
    APPLIED MATHEMATICS AND COMPUTATION, 2022, 413
  • [27] Coordinated Cyber Physical Attacks and Defense Strategy in Cyber-Physical Power Systems Based on Game Theory
    Yang, Jun
    Zhao, Yulong
    Dong, Chenchen
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2025,
  • [28] A tri-level optimization model for power grid defense with the consideration of post-allocated DGs against coordinated cyber-physical attacks
    He, Huihui
    Huang, Shengjun
    Liu, Yajie
    Zhang, Tao
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 130
  • [29] CPMTD: Cyber-physical moving target defense for hardening the security of power system against false data injected attack
    Hu, Yifan
    Zhu, Peidong
    Xun, Peng
    Liu, Bo
    Kang, Wenjie
    Xiong, Yinqiao
    Shi, Weiheng
    COMPUTERS & SECURITY, 2021, 111
  • [30] A Survey on Cyber-Attacks for Cyber-Physical Systems: Modeling, Defense, and Design
    Lian, Zhi
    Shi, Peng
    Chen, Mou
    IEEE INTERNET OF THINGS JOURNAL, 2025, 12 (02): : 1471 - 1483