Estimation of radiation dose and establishment of local diagnostic reference levels for computed tomography of head in pediatric population

被引:0
|
作者
Priyanka [1 ]
Kadavigere, Rajagopal [2 ]
Sukumar, Suresh [1 ]
机构
[1] Manipal Acad Higher Educ, Manipal Coll Hlth Profess, Dept Med Imaging Technol, Manipal, Karnataka, India
[2] Manipal Acad Higher Educ, Kasturba Med Coll, Dept Radio Diag & Imaging, Manipal 576104, Karnataka, India
关键词
Diagnostic reference levels; pediatric computed tomography; volumetric computed tomography dose index; dose length product; effective dose estimation; CT SCANS; RISK; CANCER; EXPOSURE; ADULT;
D O I
10.3233/XST-221172
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Pediatric population is more sensitive to the effects of radiation than adults. Establishing diagnostic reference level (DRL) is an efficient dose optimization technique implemented by many countries for reducing radiation dose during Computed Tomography (CT) examinations. OBJECTIVES: To estimate radiation dose and establish a new local diagnostic reference level for CT head examination in the pediatric population. MATERIALS AND METHODS: We prospectively recruited 143 pediatric patients referred for CT head examination with age ranging from 0-5 years old. All patients had undergone CT head examination using the standard pediatric head protocol. Volumetric CT dose index (CTDIvol) and dose length product (DLP) were recorded. The effective dose was first calculated. Then, 75th percentile of dose indices was calculated to establish DRLs. RESULTS: DRLs in terms of CTDIvol and DLP are 23.84 mGy, 555.99 mGy.cm for patients <1 years old and 28.65 mGy, 794.99 mGy.cm for patients from 1-5 years old, respectively. Mean effective doses for <1 years old patients and 1-5 years old patients are 2.91 mSv and 2.78 mSv respectively. CONCLUSION: The study concludes that DRL in terms of CTDIvol is lower but DRL in terms of DLP and the effective dose is higher compared to a few other studies which necessitate the need for dose optimization.
引用
收藏
页码:983 / 991
页数:9
相关论文
共 50 条
  • [21] PATIENT DOSES IN COMPUTED TOMOGRAPHY: AN ASSESSMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS IN A LARGE TEACHING HOSPITAL
    Hadnadjev, Darka R.
    Arandjic, Danijela D.
    Stojanovic, Sanja S.
    Ciraj-Bjelac, Olivera F.
    Bozovic, Predrag M.
    Stankovic, Jelena S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (03): : 305 - 310
  • [22] Estimation of diagnostic reference levels for children computed tomography: A study in Tehran, Iran
    Afzalipour, R.
    Abdollahi, H.
    Hajializadeh, M. S.
    Jafari, S.
    Mahdavi, S. R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2019, 17 (03): : 407 - 413
  • [23] Radiation Dose Reduction in Head and Neck Computed Tomography Angiography
    Zhao, Ying-Jia
    Ma, Xi
    Zheng, Ya-Ting
    Zuo, Zi-Wei
    Xu, Ying-Jin
    Wang, Jia-Ning
    Yin, Xiao-Ping
    Gao, Bu-Lang
    CURRENT MEDICAL IMAGING, 2022, 18 (07) : 757 - 763
  • [24] Dose estimation in reference and non-reference pediatric patients undergoing computed tomography examinations: a Monte Carlo study
    Akhlaghi, P.
    Miri-Hakimabad, H.
    Rafat-Motavalli, L.
    RADIOPROTECTION, 2015, 50 (01) : 43 - 54
  • [25] Strategies for Computed Tomography Radiation Dose Reduction in Pediatric Neuroimaging
    Albert, Gregory W.
    Glasier, Charles M.
    NEUROSURGERY, 2015, 77 (02) : 228 - 232
  • [26] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Najafi, Mohsen
    Deevband, Mohammad Reza
    Ahmadi, Mohsen
    Kardan, Mohammad Reza
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2015, 38 (04) : 603 - 609
  • [27] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Mohsen Najafi
    Mohammad Reza Deevband
    Mohsen Ahmadi
    Mohammad Reza Kardan
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 603 - 609
  • [28] Diagnostic reference levels for common pediatric computed tomography studies: A retrospective study.
    Khafaji, Mawya
    Barnawi, Rashid
    Amoudi, Salma
    Gabbani, Hassan
    Alhazmi, Rayan
    Ahyad, Rayan
    Alsafi, Khalid
    Saeedi, Khuld
    Salah, Hassan
    Tamam, Nissren
    Bradley, David
    Albahiti, Sarah
    Sulieman, Abdelmoneim
    RADIATION PHYSICS AND CHEMISTRY, 2024, 215
  • [29] Establishment of institutional diagnostic reference level for Computed Tomography dose on 160 slicer Computed Tomography scan at Lady Reading Hospital Peshawar
    Khan, Muhammad Imran
    Khan, Muhammad Zeeshan
    Afzal, Fariha
    Zenab
    Khan, Shandana
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2023, 73 (04) : 808 - 811
  • [30] Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa
    Dellie, Seife Teferi
    Tesfaw, Ambaye Fisehaw
    Kumsa, Marema Jebessa
    Tolawak, Birhanu Turi
    DOSE-RESPONSE, 2023, 21 (02):