The Effect of Implant Placement on Sacroiliac Joint Range of Motion

被引:47
作者
Soriano-Baron, Hector [1 ]
Lindsey, Derek P. [2 ]
Rodriguez-Martinez, Nestor [1 ]
Reyes, Phillip M. [1 ]
Newcomb, Anna [1 ]
Yerby, Scott A. [2 ]
Crawford, Neil R. [1 ]
机构
[1] St Josephs Hosp, Spinal Biomech Res Lab, Barrow Neurol Inst, Phoenix, AZ USA
[2] SI BONE Inc, San Jose, CA 95218 USA
关键词
sacroiliac; sacroiliac joint dysfunction; sacroiliac joint disruption; degenerative sacroiliitis; fusion; biomechanics; minimally invasive surgery; SCREW FIXATION; BIOMECHANICS; FRACTURES; SEGMENTS; FUSION; SACRUM;
D O I
10.1097/BRS.0000000000000839
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A human cadaveric biomechanical study of 2 sacroiliac (SI) joint fusion implant placement techniques. Objective. To evaluate and compare the biomechanical properties of 2 implant placement techniques for SI joint fusion. Summary of Background Data. Minimally invasive placement of SI joint fusion implants is a potential treatment of SI joint disruptions and degenerative sacroiliitis. Biomechanical studies of screw fixation within the sacrum have shown that placement and trajectory are important in the overall stability of the implant. Although clinical results have been promising, there is the possibility that a more optimal arrangement of implants may exist. Methods. Bilateral SI joints in 7 cadaveric lumbopelvic (L4-pelvis) specimens were tested using a single leg stance model. All joints were tested intact, pubic symphysis sectioned, and treated (3 SI joint fusion implants). The implants were laterally placed using either a posterior or transarticular placement technique. The posterior technique places the implants inline in the inlet view, parallel in the outlet view, and parallel to the posterior sacral body in the lateral view. The transarticular technique places all implants across the articular portion of the SI joint. For all conditions, the range of motion was tested in flexion-extension, lateral bending, and axial rotation. Results. The posterior technique significantly reduced the range of motion in flexion-extension, lateral bending, and axial rotation by 27% +/- 24% (P = 0.024), 28% +/- 26% (P = 0.028), and 32% +/- 21% (P = 0.008), respectively. The transarticular technique significantly reduced the range of motion in flexion-extension, lateral bending, and axial rotation by 41% +/- 31% (P = 0.013), 36% +/- 38% (P = 0.049), and 36% +/- 28% (P = 0.015), respectively. No significant differences were detected between the posterior and transarticular placement techniques (P > 0.25). Conclusion. Posterior and transarticular placement of SI joint fusion implants stabilized the SI joint in flexion-extension, lateral bending, and axial rotation.
引用
收藏
页码:E525 / E530
页数:6
相关论文
共 43 条
  • [1] Albert M J, 1993, J Orthop Trauma, V7, P226, DOI 10.1097/00005131-199306000-00005
  • [2] RECOGNIZING SPECIFIC CHARACTERISTICS OF NONSPECIFIC LOW-BACK-PAIN
    BERNARD, TN
    KIRKALDYWILLIS, WH
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (217) : 266 - 280
  • [3] Buchowski Jacob M, 2005, Spine J, V5, P520, DOI 10.1016/j.spinee.2005.02.022
  • [4] Safe placement of S1 and S2 iliosacral screws:: The "vestibule" concept
    Carlson, DA
    Scheid, DK
    Maar, DC
    Baele, JR
    Kaehr, DM
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (04) : 264 - 269
  • [5] SCREW FIXATION IN THE HUMAN SACRUM - AN INVITRO STUDY OF THE BIOMECHANICS OF FIXATION
    CARLSON, GD
    ABITBOL, JJ
    ANDERSON, DR
    KRAG, MH
    KOSTUIK, JP
    WOO, SLY
    GARFIN, SR
    [J]. SPINE, 1992, 17 (06) : S196 - S203
  • [6] Projection of the S2 pedicle onto the posterolateral surface of the ilium - A technique for lag screw fixation of sacral fractures or sacroiliac joint dislocations
    Cecil, ML
    Rollins, JR
    Ebraheim, NA
    Yeasting, RA
    [J]. SPINE, 1996, 21 (07) : 875 - 878
  • [7] Stability of transforaminal lumbar interbody fusion in the setting of retained facets and posterior fixation using transfacet or standard pedicle screws
    Chin, Kingsley R.
    Reis, Marco T.
    Reyes, Phillip M.
    Newcomb, Anna G. U.
    Neagoe, Anda
    Gabriel, Josue P.
    Sung, Roger D.
    Crawford, Neil R.
    [J]. SPINE JOURNAL, 2015, 15 (05) : 1077 - 1082
  • [8] Chip Routt M., 1993, Operat Tech Orthop, V3, P35, DOI [DOI 10.1016/S1048-6666(06)80007-8, 10.1016/S1048-6666(06)80007-8]
  • [9] Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures
    Comstock, CP
    vanderMeulen, MCH
    Goodman, SB
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1996, 10 (08) : 517 - 522
  • [10] AN APPARATUS FOR APPLYING PURE NONCONSTRAINING MOMENTS TO SPINE SEGMENTS IN-VITRO
    CRAWFORD, NR
    BRANTLEY, AGU
    DICKMAN, CA
    KOENEMAN, EJ
    [J]. SPINE, 1995, 20 (19) : 2097 - 2100