A combination of GFRP sheets and steel cage for seismic strengthening of shear-deficient corner RC beam-column joints

被引:50
作者
Esmaeeli, Esmaeel [1 ]
Danesh, Fakhreddin [2 ]
Tee, Kong Fah [1 ]
Eshghi, Sassan [3 ]
机构
[1] Univ Greenwich, Dept Engn Sci, London SE18 6PF, England
[2] KN Toosi Univ Technol, Fac Civil Engn, Tehran, Iran
[3] IIEES, Tehran, Iran
关键词
Seismic retrofitting; RC beam-column joint; GFRP sheets; Steel cage; Bidirectional loading; Cyclic behaviour; Anchorage system; FRP; REHABILITATION;
D O I
10.1016/j.compstruct.2016.09.064
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper is focused on the performance of a proposed scheme for seismic strengthening of shear deficient joints of 3D reinforced concrete (RC) corner beam-column connections. This technique is composed of a combination of GFRP sheets and a steel cage, and does not require perforating the existing concrete elements to anchor the FRP sheets. Two similar full-scale beam-column connections were made without any transverse reinforcement in their joint region. One of which was tested in its as-built condition, taken as the control specimen, while the other one was tested after strengthening. Seismic behaviour of these specimens was studied under a cyclic loading pattern imposed simultaneously with a constant column's axial load. Comparison of the test results of these specimens revealed a noticeable improvement in the seismic response of the strengthened specimen. This achievement along with the application feasibility of this technique indicates the suitability of the proposed strengthening scheme for practical applications. Finally, the experimentally obtained joint shear strength of the control and retrofitted specimens are compared to the one estimated by the relationships of the softened strut-and-tie model and ACI-318, respectively. This comparison revealed a satisfactory prediction of joint shear strength for both specimens, the as-built and the strengthened one. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:206 / 219
页数:14
相关论文
共 29 条
[1]   Seismic response of interior RC beam-column joints upgraded with FRP sheets. I: Experimental study [J].
Al-Salloum, Yousef A. ;
Almusallam, Tarek H. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2007, 11 (06) :575-589
[2]   Seismic Behavior of As-Built, ACI-Complying, and CFRP-Repaired Exterior RC Beam-Column Joints [J].
Al-Salloum, Yousef A. ;
Almusallam, Tarek H. ;
Alsayed, Saleh H. ;
Siddiqui, Nadeem A. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (04) :522-534
[3]  
[Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
[4]  
[Anonymous], 1998, FACTURE MECH CONCR S
[5]  
[Anonymous], THESIS
[6]  
[Anonymous], 2002, 352 ACIASCE
[7]   Experimental investigation of FRP-strengthened RC beam-column joints [J].
Antonopoulos, CP ;
Triantafillou, TC .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (01) :39-49
[8]   State of Research on Seismic Retrofit of RC Beam-Column Joints with Externally Bonded FRP [J].
Bousselham, Abdelhak .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (01) :49-61
[9]  
Danesh F., 2008, ASIAN J APPL SCI, V1, P217
[10]   Seismic rehabilitation of beam-column joint using GFRP sheets [J].
El-Amoury, T ;
Ghobarah, A .
ENGINEERING STRUCTURES, 2002, 24 (11) :1397-1407