Transperineal prostate intervention:: Robot for fully automated MR Imaging -: System description and proof of principle in a Canine model

被引:64
作者
Muntener, Michael [1 ]
Patriciu, Alexandru [1 ]
Petrisor, Doru [1 ]
Schar, Michael [1 ]
Ursu, Daniel [1 ]
Song, Danny Y. [1 ]
Stoianovici, Dan [1 ]
机构
[1] Johns Hopkins Med Inst, Urobot Lab, Dept Urol, JHBMC, Baltimore, MD 21224 USA
关键词
D O I
10.1148/radiol.2472070737
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The study was approved by the animal care and use committee. The purpose of the study was to prospectively establish proof of principle in vivo in canines for a magnetic resonance ( MR) imaging - compatible robotic system designed for image- guided prostatic needle intervention. The entire robot is built with nonmagnetic and dielectric materials and in its current configuration is designed to perform fully automated brachytherapy seed placement within a closed MR imager. With a 3.0- T imager, in four dogs the median error for MR imaging - guided needle positioning and seed positioning was 2.02 mm ( range, 0.86 - 3.18 mm) and 2.50 mm ( range, 1.45 - 10.54 mm), respectively. The robotic system is capable of accurate MR imaging - guided prostatic needle intervention within a standard MR imager in vivo in a canine model.
引用
收藏
页码:543 / 549
页数:7
相关论文
共 21 条
[1]  
Atalar Ergin, 2005, Magn Reson Imaging Clin N Am, V13, P491, DOI 10.1016/j.mric.2005.04.012
[2]   MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: Initial results [J].
Beyersdorff, D ;
Winkel, A ;
Hamm, B ;
Lenk, S ;
Loening, SA ;
Taupitz, M .
RADIOLOGY, 2005, 234 (02) :576-581
[3]  
Chinzei K, 2001, Med Sci Monit, V7, P153
[4]   Transperineal magnetic resonance image guided prostate biopsy [J].
D'Amico, AV ;
Tempany, CM ;
Cormack, R ;
Hata, N ;
Jinzaki, M ;
Tuncali, K ;
Weinstein, M ;
Richie, JP .
JOURNAL OF UROLOGY, 2000, 164 (02) :385-387
[5]   Real-time magnetic resonance image-guided interstitial brachytherapy in the treatment of select patients with clinically localized prostate cancer [J].
D'Amico, AV ;
Cormack, R ;
Tempany, CM ;
Kumar, S ;
Topulos, G ;
Kooy, HM ;
Coleman, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :507-515
[6]   MRI-guided diagnosis and treatment of prostate cancer. [J].
D'Amico, AV ;
Cormack, RA ;
Tempany, CM .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (10) :776-777
[7]  
DiMaio SP, 2006, STUD HEALTH TECHNOL, V119, P126
[8]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[9]  
Hempel Eckhard, 2003, Comput Aided Surg, V8, P180, DOI 10.3109/10929080309146052
[10]   Real time MRI-ultrasound image guided stereotactic prostate biopsy [J].
Kaplan, I ;
Oldenburg, NE ;
Meskell, P ;
Blake, M ;
Church, P ;
Holupka, EJ .
MAGNETIC RESONANCE IMAGING, 2002, 20 (03) :295-299