Detection of dental root fractures by using cone-beam computed tomography

被引:86
作者
Wang, P. [1 ,2 ]
Yan, X. B. [3 ,4 ]
Lui, D. G. [1 ,2 ]
Zhang, W. L. [1 ,2 ]
Zhang, Y. [1 ,2 ]
Ma, X. C. [1 ,2 ]
机构
[1] Peking Univ, Dept Oral & Maxillofacial Radiol, Sch Stomatol, Beijing 100081, Peoples R China
[2] Peking Univ, Dept Oral & Maxillofacial Radiol, Hosp Stomatol, Beijing 100081, Peoples R China
[3] Peking Univ, Stomatol Clin 1, Sch Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
[4] Peking Univ, Stomatol Clin 1, Hosp Stomatol, Special Dent Dept, Beijing 100081, Peoples R China
关键词
cone-beam computed tomography; dental radiography; diagnosis; dental root fracture; TREATED TEETH; DIAGNOSIS; CT; RADIOGRAPHY;
D O I
10.1259/dmfr/84907460
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purpose of this study was to compare the diagnostic accuracy of cone beam CT (CBCT) with that of conventional dental radiography in the detection of root fractures and to evaluate the influence of root canal fillings on root fracture detection. Methods: We investigated 128 patients with clinically suspected root fractures in 135 teeth. These patients underwent conventional dental radiography, CBCT and eventually surgical exploration. Among the 135 teeth, 86 were non-endodontically treated teeth and 49 were endodontically treated teeth. Two oral radiologists independently analysed the dental radiographs and CBCT images of each patient and reached a consensus. The CBCT findings of root fractures were set as the detection of a separation of the adjacent root segments on at least two contiguous sections and on at least two of the three-dimensional (3D) planes. Results: Root fracture was intraoperatively detected in 95 of the 135 teeth. The sensitivity and specificity of root fractures diagnosed on the basis of the consensus between the 2 evaluators were 26.3% and 100%, respectively, for dental radiography and 89.5% and 97.5%, respectively, for CBCT. CBCT was significantly more accurate than dental radiography in detecting root fractures (P < 0.001). The sensitivity of CBCT was reduced in the presence of root canal fillings but its specificity remained unaffected. Both the sensitivity and specificity of dental radiography were not influenced by the presence of root canal fillings. Conclusions: CBCT appears to be more accurate than conventional dental radiography in the detection of root fractures. Dentomaxillofacial Radiology (2011) 40, 290-298. doi: 10.1259/dmfr/84907460
引用
收藏
页码:290 / 298
页数:9
相关论文
共 23 条
[1]   Use of cone-beam volumetric tomography in the diagnosis of root fractures [J].
Bernardes, Ricardo Affonso ;
de Moraes, Ivaldo Gomes ;
Hungaro Duarte, Marco Antonio ;
Azevedo, Bruno C. ;
de Azevedo, Jose Ribamar ;
Bramante, Clovis Monteiro .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (02) :270-277
[2]   Vertical root fracture in endodontically versus nonendodontically treated teeth - A survey of 315 cases in Chinese patients [J].
Chan, CP ;
Lin, CP ;
Tseng, SC ;
Jeng, JH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1999, 87 (04) :504-507
[3]   Vertical root fracture in nonendodontically treated teeth - A clinical report of 64 cases in Chinese patients [J].
Chan, CP ;
Tseng, SC ;
Lin, CP ;
Huang, CC ;
Tsai, TP ;
Chen, CC .
JOURNAL OF ENDODONTICS, 1998, 24 (10) :678-681
[4]   A demographic analysis of vertical root fractures [J].
Cohen, Stephen ;
Berman, Louis H. ;
Blanco, Lucia ;
Bakland, Leif ;
Kim, Jay S. .
JOURNAL OF ENDODONTICS, 2006, 32 (12) :1160-1163
[5]   In vitro perception of low-contrast features in digital, film, and digitized dental radiographs: A receiver operating characteristic analysis [J].
Grassl, Ulrich ;
Schulze, Ralf Kurt Willy .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 103 (05) :694-701
[6]   Three-dimensional, non-destructive visualization of vertical root fractures using flat panel volume detector computer tomography:: an ex vivo in vitro case report [J].
Hannig, C ;
Dullin, C ;
Hülsmann, M ;
Heidrich, G .
INTERNATIONAL ENDODONTIC JOURNAL, 2005, 38 (12) :904-913
[7]   Detection of Vertical Root Fractures in Endodontically Treated Teeth by a Cone Beam Computed Tomography Scan [J].
Hassan, Bassam ;
Metska, Maria Elissavet ;
Ozok, Ahmet Rifat ;
van der Stelt, Paul ;
Wesselink, Paul Rudolf .
JOURNAL OF ENDODONTICS, 2009, 35 (05) :719-722
[8]   Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view [J].
Hirsch, E. ;
Wolf, U. ;
Heinicke, F. ;
Silva, M. A. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (05) :268-273
[9]   Root fracture detection: a comparison of direct digital radiography with conventional radiography [J].
Kositbowornchai, S ;
Nuansakul, R ;
Sikram, S ;
Sinahawattana, S ;
Saengmontri, S .
DENTOMAXILLOFACIAL RADIOLOGY, 2001, 30 (02) :106-109
[10]   DIAGNOSIS AND POSSIBLE CAUSES OF VERTICAL ROOT FRACTURES [J].
MEISTER, F ;
LOMMEL, TJ ;
GERSTEIN, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1980, 49 (03) :243-253