Two-dimensional speckle tracking echocardiography, a powerful method for the evaluation of anthracyclines induced left ventricular insufficiency

被引:9
|
作者
Chen, Wei [1 ]
Jiao, Ziyi [1 ]
Li, Wenjie [1 ]
Han, Ruoling [1 ]
机构
[1] Hebei Med Univ, Affiliated Hosp 4, Shijiazhuang, Hebei, Peoples R China
关键词
anthracyclines; two-dimensional speckle tracing echocardiography; ventricular insufficiency; CARDIOTOXICITY; STRAIN;
D O I
10.1097/MD.0000000000031084
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Anthracyclines have been one of the most important therapeutic methods in breast cancer therapy for decades. However, serious long-term toxicities, especially cardiotoxicity limits the continuous usage of anthracyclines, hence affects long term prognosis. Early detection of myocardial dysfunction during treatment is critical but challenging. Two-dimensional speckle tracking echocardiography (2D-STE) is a non-Doppler technique that can assess deformation and strain by tracking displacement of acoustic markers in the myocardium. This study aims to compare the sensitivity and precision between 2D-STE and traditional echocardiography on monitoring the left ventricular function in patients with breast cancer after anthracyclines therapy, which is the key indicator for evaluating myocardial changes. Thirty-three patients with breast cancer were recruited from February 2019 to December 2019. All patients were treated with 4 cycles anthracycline. 2D-STE and conventional echocardiography were performed on each patient. Two-dimensional echocardiographic examination was used to collect data interventricular septum diameter (IVSD), end-diastolic left ventricular posterior wall diameter (LVPWD), left ventricular end-diastolic diameter (LVEDD) and left ventricular systole on the parasternal left ventricular long axis view. The final diameter (left ventricular end-systolic diameter [LVESD]) and the left ventricular short axis shortening rate (LVFS) was measured by M-type. The two-plane Simpson's method was used to measure left ventricular end-diastolic volume (LVEDV) and end-systolic volume (left ventricular end-systolic volume [LVESV]) to obtain left ventricular ejection fraction (LVEF). Two-dimensional speckle tracking imaging technical indicator includes left ventricular global longitudinal strain (LVGLS), subendocardial myocardial longitudinal strain (LVGLS-Endo) and epicardial myocardial longitudinal strain (LVGLS-Epi). The correlation between 2-dimensional speckle tracking imaging and conventional ultrasound parameters were analyzed. Compared with baseline (T0), the systolic function parameter LVEF was significantly changed after four cycle chemotherapy (T4) (P < .05). However, the conventional echocardiographic parameters including IVSD, LVPWD, LVEDD, LVESD, LVEDV, and LVESV were not statistically significant (P > .05). Meanwhile, the two-dimensional strain parameters LVGLS, LVGLS-Endo, and LVGLS-Epi were statistically significant after T2 and T4 cycle chemotherapy (P < .01).The two-dimensional strain parameter GLS has higher accuracy and sensitivity for monitoring left ventricular insufficiency caused by anthracycline therapy when compared with traditional echocardiography.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Evaluation of the left ventricular regional function using two-dimensional speckle tracking echocardiography in patients with end-stage renal disease with preserved left ventricular ejection fraction
    Altekin, Refik Emre
    Kucuk, Murathan
    Yanikoglu, Atakan
    Karakas, M. Serkan
    Er, Arzu
    Ozel, Deniz
    Ermis, Cengiz
    Demir, Ibrahim
    ACTA CARDIOLOGICA, 2012, 67 (06) : 681 - 691
  • [22] Comparative evaluation of left ventricular function by two-dimensional echocardiography and three-dimensional speckle-tracking echocardiography in noncompaction cardiomyopathy Results from the MAGYAR-Path Study
    Kalapos Anita
    Domsik Peter
    Forster Tamas
    Nemes Attila
    ORVOSI HETILAP, 2013, 154 (34) : 1352 - 1359
  • [23] Subclinical left ventricular dysfunction in asymptomatic diabetic patients assessed by two-dimensional speckle tracking echocardiography: correlation with diabetic duration
    Nakai, Hiromi
    Takeuchi, Masaaki
    Nishikage, Tomoko
    Lang, Roberto M.
    Otsuji, Yutaka
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (08): : 926 - 932
  • [24] Two-dimensional speckle tracking echocardiography: A novel approach to evaluate left atrial mechanical function
    Fu, Huaying
    Liu, Tong
    Zhou, Changyu
    Zheng, Chenghuan
    Li, Guangping
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 155 (03) : 481 - 482
  • [25] Chronic Mitral Regurgitation: Left Atrial Deformation Analysis by Two-Dimensional Speckle Tracking Echocardiography
    Cameli, Matteo
    Lisi, Matteo
    Giacomin, Elisa
    Caputo, Maria
    Navarri, Romina
    Malandrino, Angela
    Ballo, Piercarlo
    Agricola, Eustachio
    Mondillo, Sergio
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (03): : 327 - 334
  • [26] Evaluation of Cardiac Function by Two-Dimensional Speckle Tracking Echocardiography in Ulcerative Colitis Patients
    Cincin, Altug
    Sunbul, Murat
    Kivrak, Tarik
    Atas, Halil
    Sari, Ibrahim
    Tigen, Kursat
    Kani, Tarik
    Akin, Hakan
    Imeryuz, Nese
    Basaran, Yelda
    DIGESTIVE DISEASES AND SCIENCES, 2014, 59 (12) : 3004 - 3011
  • [27] Evaluation of Cardiac Function by Two-Dimensional Speckle Tracking Echocardiography in Ulcerative Colitis Patients
    Altug Cincin
    Murat Sunbul
    Tarık Kivrak
    Halil Atas
    Ibrahim Sari
    Kursat Tigen
    Tarik Kani
    Hakan Akin
    Nese Imeryuz
    Yelda Basaran
    Digestive Diseases and Sciences, 2014, 59 : 3004 - 3011
  • [28] Impact of Cilostazol on Left Ventricular Geometry and Function: Assessment by Tissue Doppler Imaging and Two-Dimensional Speckle-Tracking Echocardiography
    Yoshikawa, Hisao
    Suzuki, Makoto
    Hashimoto, Go
    Otsuka, Takenori
    Sugi, Kaoru
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (04): : 431 - 437
  • [29] Evaluation of left atrial function using two-dimensional speckle tracking echocardiography in end-stage renal disease patients with preserved left ventricular ejection fraction
    Altekin, Refik Emre
    Yanikoglu, Atakan
    Karakas, Mustafa Serkan
    Ozel, Deniz
    Yilmaz, Huseyin
    Demir, Ibrahim
    KARDIOLOGIA POLSKA, 2013, 71 (04) : 341 - 351
  • [30] Two-dimensional speckle tracking echocardiography in evaluating radiation-induced heart damage
    Li, Tingcui
    Zhuang, Hongqing
    Wang, Yuxia
    Li, Jun
    Zhu, Dan
    Cui, Ming
    ASIA-PACIFIC JOURNAL OF ONCOLOGY NURSING, 2022, 9 (02) : 119 - 124